Detecting and Modelling Air Flow Overprovisioning / Underprovisioning in Air-Cooled Datacenters
Department of Information Engineering, University of Padova, Padova, Italy.
KTH, Department of Automatic Control, Stockholm, Sweden.
Luleå University of Technology, Department of Computer Science, Electrical and Space Engineering, Signals and Systems.ORCID iD: 0000-0002-4310-7938
RISE ICT /SICS North, Luleå, Sweden.
Show others and affiliations
2018 (English)In: Proceedings IECON 2018: 44th Annual Conference of the IEEE Industrial Electronics Society, IEEE, 2018, p. 4893-4900Conference paper, Published paper (Refereed)
Abstract [en]

When cooling and exhaust air flows in air-cooled datacenters mix, the energetic efficiency of the cooling operations drops. One way to prevent this mixing of happening is by augmenting the air tightness of the hot and cold aisles; this, however, requires installing opportune hardware that may be expensive and require time consuming installations. Alternatively, one may try to minimize cooling and exhaust air flows mixing by opportunely controlling the speeds of the fans of the Computer Room Air Handling (CRAH) units so that the distribution of the air pressure field within the computer room is favorable. Implementing this type of flow control requires both detecting when there actually is some type of flow mixing somewhere, plus understanding how to operate the cooling infrastructure so that these mixings do not happen. To this aim, there is the need for models that can both help deciding whether these mixing events occur, plus designing automatic control strategies for reducing the risks that they will happen. In this manuscript, we propose an ad-hoc methodology for the data-driven derivation of control-oriented models that serve the purposes above. The methodology is built on classical Prediction Error Method (PEM) approaches to the system identification problem, and on laddering on the peculiarities of the physics of the phenomena under consideration. Moreover, we test and assess the methodology on a industrial-scale air-cooled datacenter with an installed capacity of 240 kW, and verify that the obtained models are able to capture the dynamics of the system in all its potential regimes.

Place, publisher, year, edition, pages
IEEE, 2018. p. 4893-4900
Series
Annual Conference of Industrial Electronics Society, ISSN 1553-572X, E-ISSN 2577-1647
Keywords [en]
Datacenters cooling, statistical learning, energy efficiency, switching systems
National Category
Control Engineering
Research subject
Control Engineering
Identifiers
URN: urn:nbn:se:ltu:diva-73022DOI: 10.1109/IECON.2018.8592930ISI: 000505811104130Scopus ID: 2-s2.0-85061557374OAI: oai:DiVA.org:ltu-73022DiVA, id: diva2:1291851
Conference
44th Annual Conference of the IEEE Industrial Electronics Society (IECON 2018) 21-23 October, 2018, Washington D.C., USA
Note

ISBN för värdpublikation: 978-1-5090-6684-1, 978-1-5090-6685-8

Available from: 2019-02-26 Created: 2019-02-26 Last updated: 2020-09-08Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Varagnolo, Damiano

Search in DiVA

By author/editor
Varagnolo, Damiano
By organisation
Signals and Systems
Control Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 76 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf