Comparing Performance Metrics of Partial Aisle Containments in Hard Floor and Raised Floor Data Centers Using CFD
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Fluid and Experimental Mechanics.ORCID iD: 0000-0002-7355-5950
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Fluid and Experimental Mechanics.ORCID iD: 0000-0001-8235-9639
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Fluid and Experimental Mechanics.ORCID iD: 0000-0002-1033-0244
2019 (English)In: Energies, E-ISSN 1996-1073, Vol. 12, no 8, article id 1473Article in journal (Refereed) Published
Abstract [en]

In data centers, efficient cooling systems are required to both keep the energy consumption as low as possible and to fulfill the temperature requirements. The aim of this work is to numerically investigate the effects of using partial aisle containment between the server racks for hard and raised floor configurations. The computational fluid dynamics (CFD) software ANSYS CFX was used together with the Reynolds stress turbulence model to perform the simulations. Velocity measurements in a server room were used for validation. Boundary conditions and the load of each rack were also retrieved from the experimental facility, implying an uneven load between the racks. A combination of the performance metrics Rack Cooling Index (RCI), Return Temperature Index (RTI) and Capture Index (CI) were used to evaluate the performance of the cooling systems for two supply flow rates at a 100% and 50% of operating condition. Based on the combination of performance metrics, the airflow management was improved in the raised floor configurations. With the supply flow rate set to operating conditions, the RCI was 100% for both raised floor and hard floor setups. The top- or side-cover fully prevented recirculation for the raised floor configuration, while it reduced the recirculation for the hard floor configuration. However, the RTI was low, close to 40% in the hard floor case, indicating poor energy efficiency. With the supply flow rate decreasing with 50%, the RTI increased to above 80%. Recirculation of hot air was indicated for all the containments when the supply rate was 50%, but the values of RCI still indicated an acceptable performance of the cooling system

Place, publisher, year, edition, pages
MDPI, 2019. Vol. 12, no 8, article id 1473
Keywords [en]
data center, aisle containment, computational fluid dynamics (CFD), measurements, energy efficient
National Category
Fluid Mechanics
Research subject
Fluid Mechanics
Identifiers
URN: urn:nbn:se:ltu:diva-74676DOI: 10.3390/en12081473ISI: 000467762600066Scopus ID: 2-s2.0-85065507938OAI: oai:DiVA.org:ltu-74676DiVA, id: diva2:1326523
Note

Validerad;2019;Nivå 2;2019-06-18 (johcin)

Available from: 2019-06-18 Created: 2019-06-18 Last updated: 2025-02-09Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Wibron, EmelieLjung, Anna-LenaLundström, Staffan

Search in DiVA

By author/editor
Wibron, EmelieLjung, Anna-LenaLundström, Staffan
By organisation
Fluid and Experimental Mechanics
In the same journal
Energies
Fluid Mechanics

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 136 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf