Measurement of ice pressure on a concrete dam with a prototype ice load panelShow others and affiliations
2020 (English)In: Cold Regions Science and Technology, ISSN 0165-232X, E-ISSN 1872-7441, Vol. 170, article id 102923Article in journal (Refereed) Published
Abstract [en]
This paper presents the development and installation of a prototype ice load panel and measurements of ice load from February 2016 to February 2018 at the Rätan hydropower dam in Sweden. The design of the 1 × 3 m2 panel enables direct measurement of ice pressure on the concrete surface is based on previous experience from similar measurements with sea ice. Important features of the design are sufficient height and width to reduce scale effects and to cover the ice thickness and variations in water level. The Rätan dam was chosen based on several criteria so that the ice load is considered to be reasonably idealized against the dam structure.
For the three winters 2016, 2016/2017, 2017/2018, the maximum ice load recorded was 161 kN/m, 164 kN/m and 61 kN/m respectively. There were significant daily fluctuations during the cold winter months, and the daily peak ice loads showed a visual correlation with the daily average temperature and with the daily pattern of operation of the power station with its corresponding water level variations.
Place, publisher, year, edition, pages
Elsevier, 2020. Vol. 170, article id 102923
Keywords [en]
Static ice loads, Concrete dams, Dam safety
National Category
Other Materials Engineering
Research subject
Building Materials
Identifiers
URN: urn:nbn:se:ltu:diva-76839DOI: 10.1016/j.coldregions.2019.102923ISI: 000506666000001Scopus ID: 2-s2.0-85075037308OAI: oai:DiVA.org:ltu-76839DiVA, id: diva2:1372605
Note
Validerad;2019;Nivå 2;2019-11-25 (johcin)