Deviations between the commonly-used model and measurements of harmonic distortion in low-voltage installations
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Energy Science.ORCID iD: 0000-0003-4079-4776
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Energy Science.ORCID iD: 0000-0002-3587-7879
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Energy Science.ORCID iD: 0000-0002-9103-0226
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Energy Science.ORCID iD: 0000-0002-4004-0352
Show others and affiliations
2020 (English)In: Electric power systems research, ISSN 0378-7796, E-ISSN 1873-2046, Vol. 180, article id 106166Article in journal (Refereed) Published
Abstract [en]

Harmonic analysis studies of modern power systems commonly employ Norton and Thévenin equivalents at harmonic frequencies for the nonlinear devices. This approach neglects the so-called nonlinear interaction phenomenon. This paper addresses the difference between the results from the commonly-used model and the actual harmonic distortion measured in a low-voltage installation. A number of indices are introduced to quantify the nonlinear interaction. These indices allow a quantification of the extent to which the commonly-used model is also to predict harmonic voltages and currents in a modern low-voltage installation. The proposed model and the subsequent mathematical analysis are illustrated through measurements from different combinations of PV inverters and LED lamps using different technologies. The results show that deviation is dependent on the used technology, network impedance, and source voltage waveform. Other findings are that nonlinear interaction happens mainly in the low harmonic orders and impacts are more perceived on the harmonics phase angle. Possible explanations for these observations are discussed.

Place, publisher, year, edition, pages
Elsevier, 2020. Vol. 180, article id 106166
Keywords [en]
Power quality, Power system harmonics, Power electronics, Harmonic analysis, Nonlinear systems
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Electric Power Engineering
Identifiers
URN: urn:nbn:se:ltu:diva-77661DOI: 10.1016/j.epsr.2019.106166ISI: 000514015200052Scopus ID: 2-s2.0-85076840939OAI: oai:DiVA.org:ltu-77661DiVA, id: diva2:1392141
Funder
Swedish Energy Agency
Note

Validerad;2020;Nivå 2;2020-03-03 (alebob)

Available from: 2020-02-06 Created: 2020-02-06 Last updated: 2023-09-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Busatto, TatianoRavindran, VineethaLarsson, AndersRönnberg, SarahBollen, Math

Search in DiVA

By author/editor
Busatto, TatianoRavindran, VineethaLarsson, AndersRönnberg, SarahBollen, Math
By organisation
Energy Science
In the same journal
Electric power systems research
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 317 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf