Conformable polyimide-based μECoGs: Bringing the electrodes closer to the signal source
Department of Microsystems Engineering (IMTEK), University of Freiburg, Germany; BrainLinks-BrainTools Center, University of Freiburg, Germany; Department of Electrical Engineering (SEAS), Columbia University, New York City, USA.
Department of Microsystems Engineering (IMTEK), University of Freiburg, Germany; Center for Translational Neurophysiology of Speech and Communication (IIT), Ferrara, Italy.
Center for Translational Neurophysiology of Speech and Communication (IIT), Ferrara, Italy; Section of Human Physiology University of Ferrara, Italy.
Center for Translational Neurophysiology of Speech and Communication (IIT), Ferrara, Italy; Section of Human Physiology University of Ferrara, Italy; Section of Pharmacology, Department of Diagnostics and Public Health, University of Verona, Italy.
Show others and affiliations
2020 (English)In: Biomaterials, ISSN 0142-9612, E-ISSN 1878-5905, Vol. 255, article id 120178Article in journal (Refereed) Published
Abstract [en]

Structural biocompatibility is a fundamental requirement for chronically stable bioelectronic devices. Newest neurotechnologies are increasingly focused on minimizing the foreign body response through the development of devices that match the mechanical properties of the implanted tissue and mimic its surface composition, often compromising on their robustness. In this study, an analytical approach is proposed to determine the threshold of conformability for polyimide-based electrocorticography devices. A finite element model was used to quantify the depression of the cortex following the application of devices mechanically above or below conformability threshold. Findings were validated in vivo on rat animal models. Impedance measurements were performed for 40 days after implantation to monitor the status of the biotic/abiotic interface with both conformable and non-conformable implants. Multi-unit activity was then recorded for 12 weeks after implantation using the most compliant device type. It can therefore be concluded that conformability is an essential prerequisite for steady and reliable implants which does not only depend on the Young's modulus of the device material: it strongly relies on the relation between tissue curvature at the implantation site and corresponding device's thickness and geometry, which eventually define the moment of inertia and the interactions at the material-tissue interface.

Place, publisher, year, edition, pages
Elsevier, 2020. Vol. 255, article id 120178
Keywords [en]
Polyimide-based electrocorticography device, Bioelectronics, Conformability, Chronic stability, Brain recording, Tissue-electrode interface
National Category
Other Medical Engineering
Research subject
Medical Engineering
Identifiers
URN: urn:nbn:se:ltu:diva-79603DOI: 10.1016/j.biomaterials.2020.120178ISI: 000555693800024PubMedID: 32569863Scopus ID: 2-s2.0-85086581249OAI: oai:DiVA.org:ltu-79603DiVA, id: diva2:1441420
Note

Validerad;2020;Nivå 2;2020-06-29 (alebob)

Available from: 2020-06-16 Created: 2020-06-16 Last updated: 2025-04-23Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Asplund, Maria
By organisation
Nursing and Medical technology
In the same journal
Biomaterials
Other Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 61 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf