Comparative Analysis of Transformer-Energizing and Fault-Caused Voltage Dips on the Dynamic Behavior of DFIG-Based Wind Turbines
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Energy Science.ORCID iD: 0000-0001-5845-5620
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Energy Science.
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Energy Science.ORCID iD: 0000-0003-4074-9529
Universidade Federal do Rio Grande do Sul, Porto Alegre, Brazil .
2020 (English)In: Proceedings of 2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe) 26-28 October, 2020, IEEE, 2020, p. 589-593Conference paper, Published paper (Refereed)
Abstract [en]

This work compares the response of DFIG-based wind turbines under voltage dips caused by transformer-energizing and caused by an asymmetrical fault. Voltage dips with similar retained voltage and duration and the two distinct causes are applied to an equivalent model of a DFIG-based wind park. The dips are different in terms of harmonic content and unbalance during the recovery after the dip. Due to its slow recovery, the transformer-energizing dip results in longer fluctuation in torque, longer overshoot in DC-link voltage, and longer recovery to the pre-dip active power. Also, due to its harmonic content, the harmonic distortion in the rotor and stator current is higher for the transformer-energizing dip. As the impact is different between the transformer-energizing dip and the fault-caused dip, it is recommended to consider both events separately during low-voltage-ride-through studies.

Place, publisher, year, edition, pages
IEEE, 2020. p. 589-593
Keywords [en]
Power Quality, Voltage Dips, DFIG, Wind Turbine, Transformer Energizing, LVRT, FRT
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Electric Power Engineering
Identifiers
URN: urn:nbn:se:ltu:diva-81462DOI: 10.1109/ISGT-Europe47291.2020.9248983Scopus ID: 2-s2.0-85097355455OAI: oai:DiVA.org:ltu-81462DiVA, id: diva2:1502231
Conference
10th IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe 2020), 26-28 October, 2020, Delft, The Netherlands (Virtual)
Note

ISBN för värdpublikation: 978-1-7281-7100-5

Available from: 2020-11-19 Created: 2020-11-19 Last updated: 2021-01-11Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

de Oliveira, Roger AlvesCheng, ChenBollen, Math H.J.

Search in DiVA

By author/editor
de Oliveira, Roger AlvesCheng, ChenBollen, Math H.J.
By organisation
Energy Science
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 52 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf