Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Assessing time-varying harmonic interactions in a wind park
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Energy Science.ORCID iD: 0000-0002-3587-7879
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Energy Science.ORCID iD: 0000-0001-7528-101x
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Energy Science.ORCID iD: 0000-0002-4004-0352
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Energy Science.ORCID iD: 0000-0003-4074-9529
2021 (English)In: IEEE Access, E-ISSN 2169-3536, Vol. 9, p. 68151-68160Article in journal (Refereed) Published
Abstract [en]

The harmonic interaction mechanism in a wind park is examined in this paper. The paper investigates the feasibility of a solution to the yet challenging harmonic contribution estimation from multiple sources in a wind park with limited available information, via an extension of a simple modeling approach as well as from detailed analysis of field measurements. The paper has two distinct objectives in assessing harmonic interactions (a) one to extend the classical Norton equivalent model to a multi-measurement wind park system and to suggest potential areas for further model developments from field measurement analysis, and (b) second to draw inferences from field measurements and to develop a new independent concept of analysis from long-term field measurements in the wind park. From practical experience, a new concept of analysis with a ‘harmonic interaction break-even point’ is introduced. With the help of it, one could identify whether the primary emission (emission from considered source) or secondary emission (emission from a distant source) dominates in the analysis period. In this way, the highest responsibility between different interacting time-varying harmonic sources is evaluated. It was concluded that from long-term measurements one can define a magnitude of power production where a certain harmonic order is canceled or reaches its lowest magnitude. If one finds this cancellation point, one can define a level of secondary/primary emission or at least a feasible range. This knowledge is a step forward towards harmonic contribution analysis.

Place, publisher, year, edition, pages
IEEE, 2021. Vol. 9, p. 68151-68160
Keywords [en]
power quality, wind power generation, power system harmonics, interharmonics
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Electric Power Engineering
Identifiers
URN: urn:nbn:se:ltu:diva-83418DOI: 10.1109/ACCESS.2021.3076879ISI: 000649566600001Scopus ID: 2-s2.0-85105074281OAI: oai:DiVA.org:ltu-83418DiVA, id: diva2:1540170
Funder
Swedish Energy Agency, 245 110
Note

Validerad;2021;Nivå 2;2021-05-17 (alebob)

Available from: 2021-03-26 Created: 2021-03-26 Last updated: 2023-09-05Bibliographically approved
In thesis
1. Time-varying Waveform Distortion in Low voltage network
Open this publication in new window or tab >>Time-varying Waveform Distortion in Low voltage network
2021 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

The progressive advancement in new technologies has introduced new types of equipment into the grid. Some of these devices, which have gained significant popularity in the last few decades are photovoltaic (PV) systems and wind power systems from the generation side, and energy-efficient lighting i.e. LED lamps and energy-efficient transportation via electric vehicles from the consumption side. All these equipment essentially consist of different kinds of power electronic converters with their associated control systems. There is always feasibility of mutual interactions between these non-linear power electronic devices with the grid as well as with other grid-connected equipment placed electrically close to each other, where the control loops can face new system dynamics. Adverse interactions can cause interferences and in the worst-case lead to instability issues. A mapping of the potential interactions, in the form of emission is needed to understand interferences at the device level and system level. The overall aim of this work is to enhance the existing knowledge about the power quality aspects of the different non-linear power electronic devices that are being increasingly connected to the grid especially in low voltage networks. The conclusions derived from this study can be extended to a broader scale where there is the feasibility of multiple non-linear power electronic-based devices operating together at medium and high voltage levels.

The main contributions of the work are classified into three main parts: 

In the first part, an in-depth study of interharmonics in PV systems is carried out. Different sets of field measurements and measurements from controlled but realistic laboratory environments are investigated for interharmonic existence, persistence, and propagation. To ensure the genuinity of the observed interharmonics and to address the different challenges associated with their estimation, combinations of methods are applied and results compared. The possible reasons for their origin are systematically established through a comprehensive study. The potential system impacts which it could create in the grid and to other grid-connected equipment are investigated. The possibility for aggregation of interharmonics when multiple sources are connected to the same point of common coupling is explored via a statistical approach.

In the second part, initially harmonic interactions in wind parks, and between PV and LED lamps, are first discussed. The time-varying harmonic interaction phenomenon is studied in detail with the help of a mathematical model as well as with the help of analysis of field measurements at multiple locations of a wind park. The outcome of this study contributes to the yet challenging problem of harmonic contribution estimation in twofold. (a) A method is developed from long-term field measurements with which one could potentially identify which source of emission dominates in the analysis period, and (b) Limitations of the extended mathematical model are identified and inferences from field measurements are linked to further improve the mathematical model. Further, some specific cases of harmonic interactions between PV and LED lamps are illustrated. These examples could be a guidance for power electronic designers to increase individual device immunity subjected to harmonic interferences.

Additionally in the same part, the impact of PV induced voltage variations on different topologies of LED lamps are investigated. The considered voltage variations are distinguished as overvoltage, undervoltage, rapid voltage changes, and voltage steps due to fast-moving cloud transients, due to inverter operation itself, and due to voltage regulations caused by load tap changing operations of distribution transformers. Due to PV induced voltage variations, LED lamps are impacted in various ways. LED lamps are either potential victims of these voltage variations or LED lamps to act as sources of increased grid distortions. As potential victims, the studied LED lamps have shown changes in the light output, instability issues, and degradation in the driver efficiency. As potential sources of grid distortion, LED lamps have exhibited increased harmonic and interharmonic emissions. The difference in impact has been linked to the topology of the lamps.

In the third part, the application of a deep leaning based unsupervised machine learning method to extract waveform distortion patterns in big data for enhancing power quality knowledge is illustrated. Specifically, signal processing of interharmonics with precise frequency and amplitude estimation needs the processing of data of large volume for a higher resolution. Thus, the interharmonics analysis in long-term measurements evidences the need for an automatic tool to assist the experts. In this work, a deep learning method for the identification of spectral patterns of time-varying waveform distortion in photovoltaic installations is proposed. The PQ big data with information on harmonic and/or interharmonics in PV installations is handled by a deep autoencoder followed by feature clustering. Measurements of voltage and current from four distinct PV installations are used to illustrate the method. The proposed method accelerates the process of manual interpretation and is a starting point to determine how to proceed further with the data analysis.

Place, publisher, year, edition, pages
Skellefteå: Luleå University of Technology, 2021. p. 100
Series
Doctoral thesis / Luleå University of Technology 1 jan 1997 → …, ISSN 1402-1544
Keywords
Interharmonics, Harmonic interactions, Voltage variations, Deep learning
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Electric Power Engineering
Identifiers
urn:nbn:se:ltu:diva-83416 (URN)978-91-7790-795-4 (ISBN)978-91-7790-796-1 (ISBN)
Public defence
2021-05-26, Hörsal A, Skellefteå samt zoom, Skellefteå, 16:30 (English)
Opponent
Supervisors
Funder
Swedish Energy Agency, 245 110
Available from: 2021-03-30 Created: 2021-03-30 Last updated: 2023-09-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Ravindran, VineethaNakhodchi, NaserRönnberg, SarahBollen, Math H. J.

Search in DiVA

By author/editor
Ravindran, VineethaNakhodchi, NaserRönnberg, SarahBollen, Math H. J.
By organisation
Energy Science
In the same journal
IEEE Access
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 176 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf