Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Induktionsdriven förbränningstoalett: Utveckling och test av förbränningssystem
Luleå University of Technology, Department of Engineering Sciences and Mathematics.
2024 (Swedish)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [sv]

Denna rapport dokumenterar den fortsatta utvecklingen av en förbränningstoalett på företaget Ozoneair. Förbränningstoaletter är ett hygieniskt sätt att hantera avfall i situationer där standardlösningar är för dyra eller otillgängliga. De hanterar avfall genom att bränna det ned till en steril aska genom att koka av all vätska och sedan genom att uppnå temperaturer höga nog att nå avfallets antändningspunkt. När antändning har nåtts så behöver ingen mer värme tillföras utan förbränningstoaletten tillför bara ett luftföde. den fortsatta utvecklingen i projektet inkluderade delarna som är dedikerade till att nå antändningstemperatur och nå fullständig förbränning. Dessa komponenter inkluderar ventilation, kammare, isolering, askbehållare, och induktions system. Vid projektets slut var målet att ha en prototyp som kunde uppnå antändningstemperatur och utföra hela förbrännings och kylnings cykeln. Projektet resulterade i en prototyp som klarade av de satta målen och var fullt fungerande, men många komponenter var i en experimentell form.

Abstract [en]

This report documents the continuing development of an incineration toilet at the company Ozoneair. Incineration toilets are a hygienic way to handle waste in situations where standard solutions are too expensive or unavailable. They dispose of the waste by incinerating it down to sterile ashes by frst boiling of the fuids and then reaching temperatures high enough to reach the wastes ignition point. Once ignition has started the toilet no longer needs to keep heating the waste and instead only maintain airfow. The continuing development from this project was to be contained to the parts used for reaching the ignition temperature and complete the incineration. This included ventilation, chamber, insulation, ash container and induction system. At the end of the project the goal was to have a prototype able to reach ignition temperature and complete the combustion and cooling cycle. The project resulted in a prototype that meets the goals and was fully functioning, but many parts were still in an experimental form.

Place, publisher, year, edition, pages
2024. , p. 100
National Category
Mechanical Engineering
Identifiers
URN: urn:nbn:se:ltu:diva-107530OAI: oai:DiVA.org:ltu-107530DiVA, id: diva2:1871478
External cooperation
Ozoneair AB
Subject / course
Student thesis, at least 30 credits
Educational program
Mechanical Engineering, master's level
Presentation
2024-05-21, E234, Laboratorievägen 14, 971 87, Luleå, 10:30 (Swedish)
Supervisors
Examiners
Available from: 2024-06-17 Created: 2024-06-17 Last updated: 2024-06-17Bibliographically approved

Open Access in DiVA

No full text in DiVA

Search in DiVA

By author/editor
Hermansson, Linus
By organisation
Department of Engineering Sciences and Mathematics
Mechanical Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 39 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf