Influence of natural convection in water-filled boreholes for GCHP
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Architecture and Water.
Swedish Society of HVAC Engineers, Stockholm.
2008 (English)In: ASHRAE Transactions, ISSN 0001-2505, Vol. 114, no 1, p. 416-423Article in journal (Refereed) Published
Abstract [en]

In groundwater filled borehole heat exchangers (BHE), convective flow inside the borehole water will affect the heat transfer. Since the convective flow is dependent of the temperature gradient, different injection rates and ground temperatures will result in different borehole thermal resistance. This paper describes the influence of natural convection in water-filled boreholes in impermeable bedrock for ground-coupled heat pump (GCHP) systems. An overview of groundwater-filled boreholes and the influence of groundwater movements are presented followed by numerical simulations and field measurements to further investigate the influence. The results from the simulations of the three-dimensional, steady-state model of a 9.8 ft (3 m) deep BHE are compared to evaluated results from performed thermal response test (TRT). The results show that convective flow in groundwater-filled BHE results in 5-9 times more efficient heat transfer compared to stagnant water when heat carrier temperatures are in the range of 50-86°F (10-30°C). The size of the convective flow depends on the temperature gradients in the borehole. This shows the importance of on-site investigation of thermal properties using appropriate power injection rates similar to those in the system to be built. This research is part of an on-going project to find ways to estimate the heat transfer including convective flow and to incorporate the findings into the design of GCHP systems. TRT are today a common way to determine heat transfer properties for a BHE and its surroundings. Performing TRT measurements with several injection rates is a way to evaluate the dynamic thermal response including the change in convective flow due to changes in temperature levels. If this dynamic response would be included in design tools a more thorough design of the BHE system is performed. Here, the early result of this research is presented

Place, publisher, year, edition, pages
2008. Vol. 114, no 1, p. 416-423
National Category
Water Engineering
Research subject
Water Resources Engineering; Urban Water Engineering
Identifiers
URN: urn:nbn:se:ltu:diva-3765Scopus ID: 2-s2.0-55849091736Local ID: 198cd69f-ef6e-4bb9-ae5b-7ca88659b545OAI: oai:DiVA.org:ltu-3765DiVA, id: diva2:976626
Conference
Winter meeting of the American Society of Heating, Refrigerating and Air-Conditioning Engineers : 19/01/2008 - 23/01/2008
Note

Godkänd; 2008; 20110214 (andbra)

Available from: 2016-09-29 Created: 2016-09-29 Last updated: 2023-10-06Bibliographically approved

Open Access in DiVA

No full text in DiVA

Scopus

Authority records

Gustafsson, Anna-Maria

Search in DiVA

By author/editor
Gustafsson, Anna-Maria
By organisation
Architecture and Water
In the same journal
ASHRAE Transactions
Water Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 182 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf