Failure load test of a CFRP strengthened railway bridge in Örnsköldsvik, Sweden
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering.
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Structural and Construction Engineering.ORCID iD: 0000-0001-7799-5809
2009 (English)In: Journal of Bridge Engineering, ISSN 1084-0702, E-ISSN 1943-5592, Vol. 14, no 5, p. 300-308Article in journal (Refereed) Published
Abstract [en]

The results obtained when performing a load test to failure of an existing structure are valuable when assessing calculation models, updating finite element models, and investigating the true structural behavior. In this paper a destructive testing and monitoring of a railway bridge in Örnsköldsvik, Sweden is presented. In this particular test the shear capacity of the concrete girders was of primary interest. However, for any reasonable placement of the load (a line load placed transverse to the track direction) a bending failure would occur. This problem was solved by strengthening for flexure using carbon fiber reinforced polymer (CFRP) rectangular rods epoxy bonded in sawed up slots, e.g., near surface mounted reinforcement. The strengthening was very successful and resulted in a desired shear failure when the bridge was loaded to failure. The load-carrying capacity in bending for the unstrengthened and strengthened bridge as well as the shear capacity was predicted with Monte Carlo simulations. The particular calculation presented showed that there was a 25% probability of a bending failure instead of a shear failure. Monitoring showed that the strengthening reduced the strain in the tensile steel reinforcement by approximately 10%, and increased the height of the compressed zone by 100 mm. When the shear failure occurred, the utilization of the compression concrete and CFRP rods were 100 and 87.5%, respectively. This indicates that a bending failure indeed was about to occur, even though the final failure was in shear.

Place, publisher, year, edition, pages
2009. Vol. 14, no 5, p. 300-308
National Category
Infrastructure Engineering
Research subject
Structural Engineering
Identifiers
URN: urn:nbn:se:ltu:diva-5921DOI: 10.1061/(ASCE)BE.1943-5592.0000005Scopus ID: 2-s2.0-69149102158Local ID: 41bc5bc0-939f-11de-8da0-000ea68e967bOAI: oai:DiVA.org:ltu-5921DiVA, id: diva2:978797
Note
Validerad; 2009; 20090828 (ysko)Available from: 2016-09-29 Created: 2016-09-29 Last updated: 2018-07-10Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records BETA

Bergström, MarkusTäljsten, BjörnCarolin, Anders

Search in DiVA

By author/editor
Bergström, MarkusTäljsten, BjörnCarolin, Anders
By organisation
Department of Civil, Environmental and Natural Resources EngineeringStructural and Construction Engineering
In the same journal
Journal of Bridge Engineering
Infrastructure Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 59 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf