Comparison of Goldmann applanation and applanation resonance tonometry in a biomicroscope-based in vitro porcine eye model
Umeå University Hospital, Department of Biomedical Engineering & Informatics.
Umeå University, Department of Clinical Science, Ophthalmology.
Umeå University, Centre for Biomedical Engineering and Physics.
Show others and affiliations
2006 (English)In: Journal of Medical Engineering & Technology, ISSN 0309-1902, E-ISSN 1464-522X, Vol. 30, no 6, p. 345-52Article in journal (Refereed) Published
Abstract [en]

We have developed an in vitro porcine eye model based on a biomicroscope, to simulate a clinical situation for IOP measurement on enucleated eyes. The aims of this study were to evaluate the model and to apply and compare Goldmann applanation tonometry (GAT) and applanation resonance tonometry (ART) measurements in porcine eyes. The GAT measurement (IOPGAT) showed a lower pressure, mean - 14.0 mm Hg (SD = 1.7 mm Hg) as compared with the reference pressure. For in vitro measurement with GAT on porcine eyes the linear calibration was IOP = 1.14 IOPGAT + 12.5 mm Hg (R2 = 0.99, p < 0.001, n = 280, four eyes). ART measurements correlated significantly to reference IOP, R = 0.86 (p < 0.001, n = 252, six eyes), with a mean difference of 5.4 mm Hg (SD = 6.7 mm Hg). GAT could only be used on porcine eyes if the IOP exceeded 13 mm Hg. Evaluation of the ART in this in vitro model showed position dependence for the sensor. To facilitate centre positioning a guiding tool is suggested. Porcine eyes are a possible substitute for human eyes in in vitro models for pre-clinical evaluation of new tonometry methods.

Place, publisher, year, edition, pages
2006. Vol. 30, no 6, p. 345-52
National Category
Other Medical Engineering
Research subject
Medical Engineering for Healthcare
Identifiers
URN: urn:nbn:se:ltu:diva-6295DOI: 10.1080/03091900512331332528PubMedID: 17060162Scopus ID: 2-s2.0-33747010633Local ID: 4818ee30-0f61-11dc-b9dd-000ea68e967bOAI: oai:DiVA.org:ltu-6295DiVA, id: diva2:979172
Note
Upprättat; 2006; 20070531 (andbra)Available from: 2016-09-29 Created: 2016-09-29 Last updated: 2023-05-08Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Lindahl, Olof

Search in DiVA

By author/editor
Lindahl, Olof
In the same journal
Journal of Medical Engineering & Technology
Other Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 98 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf