High temperature solar heated seasonal storage system for low temperature heating of buildings
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Architecture and Water.ORCID iD: 0000-0001-7144-9778
2000 (English)In: Solar Energy, ISSN 0038-092X, E-ISSN 1471-1257, Vol. 69, no 6, p. 511-523Article in journal (Refereed) Published
Abstract [en]

A preliminary study of a solar-heated low-temperature space-heating system with seasonal storage in the ground has been performed. The system performance has been evaluated using the simulation models TRNSYS and MINSUN together with the ground storage module DST. The study implies an economically feasible design for a total annual heat demand of about 2500 MWh. The main objective was to perform a study on Anneberg, a planned residential area of 90 single-family houses with 1080 MWh total heat demand. The suggested heating system with a solar fraction of 60% includes 3000 m2 of solar collectors but electrical heaters to produce peak heating. The floor heating system was designed for 30°C supply temperature. The temperature of the seasonal storage unit, a borehole array in crystalline rock of 60,000 m3, varies between 30 and 45°C over the year. The total annual heating costs, which include all costs (including capital, energy, maintenance etc.) associated with the heating system, were investigated for three different systems: solar heating (1000 SEK MWh−1), small-scale district heating (1100 SEK MWh−1) and individual ground-coupled heat pumps (920 SEK MWh−1). The heat loss from the Anneberg storage system was 42% of the collected solar energy. This heat loss would be reduced in a larger storage system, so a case where the size of the proposed solar heating system was enlarged by a factor of three was also investigated. The total annual cost of the solar heating system was reduced by about 20% to about 800 SEK MWh−1, which is lower than the best conventional alternative.

Place, publisher, year, edition, pages
2000. Vol. 69, no 6, p. 511-523
National Category
Water Engineering
Research subject
Water Resources Engineering
Identifiers
URN: urn:nbn:se:ltu:diva-6486DOI: 10.1016/S0038-092X(00)00120-1ISI: 000165963000008Scopus ID: 2-s2.0-0034501051Local ID: 4b594740-6f5f-11db-962b-000ea68e967bOAI: oai:DiVA.org:ltu-6486DiVA, id: diva2:979371
Note
Validerad; 2000; 20061006 (pafi)Available from: 2016-09-29 Created: 2016-09-29 Last updated: 2018-07-10Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Nordell, BoHellström, Göran

Search in DiVA

By author/editor
Nordell, BoHellström, Göran
By organisation
Architecture and Water
In the same journal
Solar Energy
Water Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 41 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf