Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Validation of a novel method for continuous saline tonometry in a porcine model
Department of Surgical and Perioperative Science, Umeå University.
Department of Surgical and Perioperative Science, Umeå University.
Umeå University Hospital, Department of Biomedical Engineering & Informatics.
Show others and affiliations
2001 (English)In: Physiological Measurement, ISSN 0967-3334, E-ISSN 1361-6579, Vol. 22, no 3, p. 453-460Article in journal (Refereed) Published
Abstract [en]

Only intermittent and semi-continuous tonometric measurement of gastric and intestinal pHi is possible with the equipment available today. Earlier we developed a system for continuous saline tonometry and tested it in vitro. To assess the in vivo reliability of this method for continuous gastrointestinal saline tonometry, a standard tonometer for measurement of intestinal pCO2 and corresponding pHi was modified to allow continuous perfusion of physiological saline in a closed system and tested in a porcine model. In 11 anaesthetized and haemodynamically stable pigs, two continuous tonometry balloons were inserted into the distal small bowel, and a standard tonometry balloon was used as reference. To test long-term function of the continuous tonometers the research protocol lasted for eight hours. The two continuous saline tonometers performed well, and after an equilibration time of three hours the mean pHi values were stable between 7.35 and 7.43 and between 7.32 and 7.39 respectively. The standard tonometer measured stable pHi values. These preliminary studies indicate that continuous saline tonometry performs well over eight hours with a small bias and a good precision

Place, publisher, year, edition, pages
2001. Vol. 22, no 3, p. 453-460
National Category
Other Medical Engineering
Research subject
Medical Engineering for Healthcare
Identifiers
URN: urn:nbn:se:ltu:diva-7242DOI: 10.1088/0967-3334/22/3/304ISI: 000170762600006PubMedID: 11556666Scopus ID: 2-s2.0-0034873218Local ID: 593755a0-0e0b-11dc-8745-000ea68e967bOAI: oai:DiVA.org:ltu-7242DiVA, id: diva2:980131
Note

Upprättat; 2001; 20070529 (andbra)

Available from: 2016-09-29 Created: 2016-09-29 Last updated: 2023-05-09Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Lindahl, Olof

Search in DiVA

By author/editor
Lindahl, Olof
In the same journal
Physiological Measurement
Other Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 162 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf