Mineral based bonding of carbon FRP to strengthen concrete structures
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Structural and Construction Engineering.ORCID iD: 0000-0001-7799-5809
2007 (English)In: Journal of composites for construction, ISSN 1090-0268, E-ISSN 1943-5614, Vol. 11, no 2, p. 120-128Article in journal (Refereed) Published
Abstract [en]

The advantages of fiber-reinforced polymer (FRP)-strengthening have been shown time and again during the last decade. Several thousand structures retrofitted with FRPs exist worldwide. There are various reasons why the retrofit is needed, but it is not uncommon for the demands on the structure to change with time, as buildings and civil structures usually have a very long life. The structures may have to eventually carry larger loads or fulfill new standards. In extreme cases, a structure may need repair due to an accident or to errors made during the design or construction phases, and must therefore be strengthened before it can be used. Different methods to retrofit with FRPs also exist, such as bonding of plates or sheets, with their use of epoxy as the bonding agent being the commonality. Epoxy provides very good bond to concrete and is durable and resistant to most environments in the building industry. However, epoxy may also create problems in the working environment, needs a minimum application temperature, and creates diffusion-closed surfaces. These drawbacks can be overcome if the epoxy can be replaced with a cementitious bonding agent. In this paper tests are presented where the epoxy has been replaced with a cement based bonding agent for retrofitting. Pilot tests show that very good composite action can be achieved and that only minor changes in the design procedure need to be taken.

Place, publisher, year, edition, pages
2007. Vol. 11, no 2, p. 120-128
National Category
Infrastructure Engineering
Research subject
Structural Engineering
Identifiers
URN: urn:nbn:se:ltu:diva-7796DOI: 10.1061/(ASCE)1090-0268(2007)11:2(120)ISI: 000245529800003Scopus ID: 2-s2.0-33947321729Local ID: 637d2860-09f0-11dc-9854-000ea68e967bOAI: oai:DiVA.org:ltu-7796DiVA, id: diva2:980686
Note
Validerad; 2007; 20070524 (ysko)Available from: 2016-09-29 Created: 2016-09-29 Last updated: 2018-07-10Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records BETA

Täljsten, BjörnBlanksvärd, Thomas

Search in DiVA

By author/editor
Täljsten, BjörnBlanksvärd, Thomas
By organisation
Structural and Construction Engineering
In the same journal
Journal of composites for construction
Infrastructure Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 16 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf