Effects of pulsating flow on an ultrasonic gas flow meter
1994 (English)In: Flow Measurement and Instrumentation, ISSN 0955-5986, E-ISSN 1873-6998, Vol. 5, no 2, p. 93-101Article in journal (Refereed) Published
Abstract [en]

A series of tests was carried out to assess the effects of pulsating flow on a small-dimension ultrasonic gas flowmeter. Three different parameters were investigated: pulsation amplitude, pulsation frequency and mean flow velocity. The measurements were carried out in air using a 100D straight pipe upstream of the ultrasonic gas flowmeter. The performance of the flowmeter was tested at mean flow rates from 1.2 to 9.6 m s-1, using four different pulsation frequencies (2, 5, 10 and 20 Hz) with pulsation amplitudes from 0 to ≈70% r.m.s. Our measurements reveal three major phenomena affecting the ultrasonic flowmeter performance. (1) Sampling phenomena, i.e. aliasing: it is shown that a mismatch between the setting of the sampling parameters in the flowmeter and the frequency of the pulsations can result in large positive and negative errors due to aliasing. (2) Errors due to changes of the flow profile caused by an imaginary high Reynolds number due to the pulsating flow: it is shown that these errors are proportional to the pulsation amplitude and inversely proportional to the pulsation frequency. Further, the error caused by a change in the flow profile generally appears in the laminar and transition areas. (3) Non-linearities when averaging very high or low flow velocities, respectively: very large pulsation amplitudes result in instantaneous flow velocities, sometimes exceeding both the maximum and the minimum limits of the calibrated range of the meter. For the ultrasonic meter tested, this results in large negative errors due to non-linearities on the extremes of the error curve of the meter.

Place, publisher, year, edition, pages
1994. Vol. 5, no 2, p. 93-101
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Industrial Electronics
Identifiers
URN: urn:nbn:se:ltu:diva-8885DOI: 10.1016/0955-5986(94)90042-6Local ID: 76f5b5c0-d871-11db-a1bf-000ea68e967bOAI: oai:DiVA.org:ltu-8885DiVA, id: diva2:981823
Note

Upprättat; 1994; 20070322 (ysko)

Available from: 2016-09-29 Created: 2016-09-29 Last updated: 2017-11-24Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records BETA

Delsing, Jerker

Search in DiVA

By author/editor
Delsing, Jerker
In the same journal
Flow Measurement and Instrumentation
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 35 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf