The use of Pt guard electrode in inductively coupled plasma sector field mass spectrometry: advantages and limitations
Luleå tekniska universitet.
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Geosciences and Environmental Engineering.ORCID iD: 0000-0003-4505-4590
2000 (English)In: Journal of Analytical Atomic Spectrometry, ISSN 0267-9477, E-ISSN 1364-5544, Vol. 15, no 4, p. 359-364Article in journal (Refereed) Published
Abstract [en]

Performance characteristics of inductively coupled plasma sector field mass spectrometry (ICP-SFMS) were studied with a Pt guard electrode (GE) inserted between the torch and load coil. The importance of the optimisation procedure and the matrix effects caused by a seawater matrix were assessed for 20 elements. Oxide and doubly charged ion formation was also investigated. Use of the GE allows a significant increase in ion transmission, by a factor of three to 20, thus resulting in improved instrumental detection limits. The improvement in sensitivity is mass dependent, with the highest gain observed for lower mass elements. Since, for the majority of analytical applications, actual detection limits depend upon blank levels rather on instrumental sensitivity, the most important factor for the determination of elements at ultra-trace levels is the degree of contamination of reagents and containers used. At the same time, significantly greater oxide formation is observed when operating the GE grounded rather than in the floating mode. For example, the BaO+/Ba+ ratio is ten to twelve times higher in the grounded mode. This calls for compromised instrumental parameters and the potential for severe spectral interferences from oxide species, which are often unresolved, even in high-resolution mode. Furthermore, non-spectral interferences from the seawater matrix appear to be more pronounced with the grounded GE, yielding a recovery of Ni of 55% compared with 93% in the floating GE mode. Hence all possible advantages and limitations of the use of the GE should be carefully considered prior to the analysis of real samples.

Place, publisher, year, edition, pages
2000. Vol. 15, no 4, p. 359-364
National Category
Geochemistry
Research subject
Applied Geology
Identifiers
URN: urn:nbn:se:ltu:diva-8955DOI: 10.1039/a906531hISI: 000086323700009Scopus ID: 2-s2.0-0033879459Local ID: 7830b000-b7b2-11db-abff-000ea68e967bOAI: oai:DiVA.org:ltu-8955DiVA, id: diva2:981893
Note
Validerad; 2000; 20070208 (ysko)Available from: 2016-09-29 Created: 2016-09-29 Last updated: 2018-07-10Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records BETA

Rodushkin, IlyaBaxter, Douglas

Search in DiVA

By author/editor
Rodushkin, IlyaBaxter, Douglas
By organisation
Geosciences and Environmental Engineering
In the same journal
Journal of Analytical Atomic Spectrometry
Geochemistry

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 46 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf