Publikationer (10 of 84) Visa alla publikationer
Mattsson, J., Hedström, A., Westerlund, L., Dahl, J., Ashley, R. & Viklander, M. (2018). Impacts on rural wastewater systems in subarctic regions due to changes in inputs from households (ed.). Journal of cold regions engineering, 32(1), Article ID 04017019.
Öppna denna publikation i ny flik eller fönster >>Impacts on rural wastewater systems in subarctic regions due to changes in inputs from households
Visa övriga...
2018 (Engelska)Ingår i: Journal of cold regions engineering, ISSN 0887-381X, E-ISSN 1943-5495, Vol. 32, nr 1, artikel-id 04017019Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The use of water-saving appliances and heat exchangers is becoming increasingly popular to decrease water consumption and recover energy from preheated water. However, such in-household changes can bring particular implications for subarctic rural areas, in terms of solids deposition in sewers and drops in performance of wastewater treatment plants (WWTPs), because these are already experiencing diminishing wastewater flows due to depopulation and seasonal dips in wastewater temperature resulting from infiltration into sewers. Hence, this study has considered two communities in Sweden, postulating three different cases with various scales of retrofitting and usage. The results indicate that the decrease in in-pipe velocities when all households are retrofitted with water-saving appliances could be counteracted by sewer relining, but not by the inclusion of a conventional estimate of infiltration. However, for the case in which retrofitting was combined with decreased usage of the appliances, the decrease in self-cleansing capacity could not be counteracted. The retrofitting of heat exchangers under shower trays in all households did not have a significant effect on treatment processes at the WWTP.

Ort, förlag, år, upplaga, sidor
American Society of Civil Engineers (ASCE), 2018
Nationell ämneskategori
Vattenteknik Energiteknik
Forskningsämne
VA-teknik; Energiteknik
Identifikatorer
urn:nbn:se:ltu:diva-14539 (URN)10.1061/(ASCE)CR.1943-5495.0000145 (DOI)000428257200005 ()2-s2.0-85030121882 (Scopus ID)de948167-31d8-4bac-a3d7-ca6af781096b (Lokalt ID)de948167-31d8-4bac-a3d7-ca6af781096b (Arkivnummer)de948167-31d8-4bac-a3d7-ca6af781096b (OAI)
Anmärkning

Validerad;2017;Nivå 2;2017-09-25 (andbra)

Tillgänglig från: 2016-09-29 Skapad: 2016-09-29 Senast uppdaterad: 2025-10-21Bibliografiskt granskad
Vesterlund, M., Toffolo, A. & Dahl, J. (2017). Optimization of multi-source complex district heating network, a case study. Energy, 126, 53-63
Öppna denna publikation i ny flik eller fönster >>Optimization of multi-source complex district heating network, a case study
2017 (Engelska)Ingår i: Energy, ISSN 0360-5442, E-ISSN 1873-6785, Vol. 126, s. 53-63Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The level of complexity for a district heating network increases with the maturity of the network, and this affects the pattern of the distribution of the hot water from the heat production sites to the end users. The majority of district heating systems are also multi-source networks, typically supported with heat from one main production site and other smaller satellite sites that are activated when required. In general, local energy companies have a lack of knowledge regarding how a meshed network behaves when different production sites are operated. The schedule of heat generation at the different sites is often based on staff experience and some general rules of thumb.

In this paper a method for modeling and simulating complex district networks is further developed in order to optimize the total operating costs of a multi-source network, with constraints on the pressure and temperature levels in the user areas and on the heat generation characteristics at each production site.

The optimization results show that the usage of the cheapest resources is preferred to a distributed generation of heat, even if some of the pipes may exceed the recommended thermal load capacity. The main site water supply temperature is found to be the lowest allowed by the constraint on the temperature of the water supplied to the end users, since the decrease of the costs associated with the lower thermal losses in the network is not counterbalanced by the increase of those associated with the pumping power of a larger water mass flow rate.

Ort, förlag, år, upplaga, sidor
Elsevier, 2017
Nyckelord
Optimization, Multi source, Heat production, Complex network, District heating
Nationell ämneskategori
Energiteknik
Forskningsämne
Energiteknik
Identifikatorer
urn:nbn:se:ltu:diva-62320 (URN)10.1016/j.energy.2017.03.018 (DOI)000404305900006 ()2-s2.0-85014911271 (Scopus ID)
Anmärkning

Validerad; 2017; Nivå 2; 2017-03-15 (rokbeg)

Tillgänglig från: 2017-03-06 Skapad: 2017-03-06 Senast uppdaterad: 2026-02-16Bibliografiskt granskad
Pericault, Y., Hedström, A., Dahl, J., Vesterlund, M. & Olsson, G. (2016). District heat tracing of water and sewer lines in Kiruna, Sweden (ed.). Paper presented at Sanitation in Cold Climate Regions : 12/04/2016 - 14/04/2016. Paper presented at Sanitation in Cold Climate Regions : 12/04/2016 - 14/04/2016.
Öppna denna publikation i ny flik eller fönster >>District heat tracing of water and sewer lines in Kiruna, Sweden
Visa övriga...
2016 (Engelska)Konferensbidrag, Enbart muntlig presentation (Övrigt vetenskapligt)
Nationell ämneskategori
Vattenteknik Energiteknik
Forskningsämne
VA-teknik; Energiteknik
Identifikatorer
urn:nbn:se:ltu:diva-35022 (URN)9642777e-1d16-404d-9344-4e07c651bbba (Lokalt ID)9642777e-1d16-404d-9344-4e07c651bbba (Arkivnummer)9642777e-1d16-404d-9344-4e07c651bbba (OAI)
Konferens
Sanitation in Cold Climate Regions : 12/04/2016 - 14/04/2016
Anmärkning
Godkänd; 2016; 20160125 (youper)Tillgänglig från: 2016-09-30 Skapad: 2016-09-30 Senast uppdaterad: 2026-02-16Bibliografiskt granskad
Johansson, T., Vesterlund, M., Olofsson, T. & Dahl, J. (2016). Energy performance certificates and 3-dimensional city models as a means to reach national targets: A case study of the city of Kiruna (ed.). Energy Conversion and Management, 116, 42-57
Öppna denna publikation i ny flik eller fönster >>Energy performance certificates and 3-dimensional city models as a means to reach national targets: A case study of the city of Kiruna
2016 (Engelska)Ingår i: Energy Conversion and Management, ISSN 0196-8904, E-ISSN 1879-2227, Vol. 116, s. 42-57Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Enhanced dissemination of information regarding energy saving and climate change targeted toward property owners is considered to be an important strategy in order to reach the Swedish national target of energy efficiency in the building sector by 2050. Here the municipality energy advisors and the national register for energy performance certificates can facilitate the mitigation of energy use in the building stock. So far few studies have focused on the practical road map to the national target of energy use on the city/district level and to the communication aspects with stakeholders in the creation of energy city models.In this paper a city energy model is developed based on the requests and need for visualization from a group of energy advisors. Six different scenarios are studied in order to analyze the possibility of reaching the energy targets specified by the government in the town of Kiruna. The results show that: (1) it is possible to automatically create city energy models using extract, transform and load tools based on spatial and non-spatial data from national registers and databases; (2) city energy models improve the understanding of energy use in buildings and can therefore be a valuable tool for energy advisors, real estate companies and urban planners. The case study of Kiruna showed that the proposed energy saving measures in the energy performance certificates need to be implemented and new buildings in the urban transformation must be of high energy standard in order to reach the national target in Kiruna.

Ort, förlag, år, upplaga, sidor
Elsevier, 2016
Nationell ämneskategori
Byggprocess och förvaltning Energiteknik
Forskningsämne
Byggproduktion; Energiteknik
Identifikatorer
urn:nbn:se:ltu:diva-14165 (URN)10.1016/j.enconman.2016.02.057 (DOI)000373749800005 ()2-s2.0-84960080826 (Scopus ID)d82fcec8-829a-4bc9-a429-8e0d2c0bcef3 (Lokalt ID)d82fcec8-829a-4bc9-a429-8e0d2c0bcef3 (Arkivnummer)d82fcec8-829a-4bc9-a429-8e0d2c0bcef3 (OAI)
Anmärkning
Validerad; 2016; Nivå 2; 20160310 (andbra)Tillgänglig från: 2016-09-29 Skapad: 2016-09-29 Senast uppdaterad: 2026-03-12Bibliografiskt granskad
Vesterlund, M., Toffolo, A. & Dahl, J. (2016). Optimization of multi-source complex district heating network: a case study. In: Proceeding of 29th International Conference on efficiency, Cost, Optimization, Simulation and Enviromental Impact of Energy Systems: . Paper presented at 29th international conference on Efficiency, Cost, Optimisation, Simulation and Environmental Impact of Energy Systems, ECOS 2016, Portorož, Slovenia, June 19. - 23. 2016.
Öppna denna publikation i ny flik eller fönster >>Optimization of multi-source complex district heating network: a case study
2016 (Engelska)Ingår i: Proceeding of 29th International Conference on efficiency, Cost, Optimization, Simulation and Enviromental Impact of Energy Systems, 2016Konferensbidrag, Muntlig presentation med publicerat abstract (Refereegranskat)
Abstract [en]

The level of complexity for a district heating network increases with the maturity of the network, and this affects the pattern of the distribution of the hot water from the heat production sites to the end users. The majority of district heating systems are also multi-source networks, typically supported with heat from one main production site and other smaller satellite sites that are activated when required. In general, local energy companies have a lack of knowledge regarding how a meshed network behaves when different production sites are operated. The schedule of heat generation at the different sites is often based on staff experience and some general rules of thumb.

In this paper a method for modeling and simulating complex district networks is further developed in order to optimize the total operating costs of a multi-source network, with constraints on the pressure and temperature levels in the user areas and on the heat generation characteristics at each production site.

The optimization results show that the usage of the cheapest resources is preferred to a distributed generation of heat, even if some of the pipes may exceed the recommended thermal load capacity. The main site water supply temperature is found to be the lowest allowed by the constraint on the temperature of the water supplied to the end users, since the decrease of the costs associated with the lower thermal losses in the network is not counterbalanced by the increase of those associated with the pumping power of a larger water mass flow rate.

Nationell ämneskategori
Energiteknik
Forskningsämne
Energiteknik
Identifikatorer
urn:nbn:se:ltu:diva-60957 (URN)
Konferens
29th international conference on Efficiency, Cost, Optimisation, Simulation and Environmental Impact of Energy Systems, ECOS 2016, Portorož, Slovenia, June 19. - 23. 2016
Tillgänglig från: 2016-12-07 Skapad: 2016-12-07 Senast uppdaterad: 2026-02-16Bibliografiskt granskad
Vesterlund, M., Toffolo, A. & Dahl, J. (2016). Simulation and analysis of a meshed district heating network (ed.). Energy Conversion and Management, 122, 63-73
Öppna denna publikation i ny flik eller fönster >>Simulation and analysis of a meshed district heating network
2016 (Engelska)Ingår i: Energy Conversion and Management, ISSN 0196-8904, E-ISSN 1879-2227, Vol. 122, s. 63-73Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The flow distribution in a district heating network tends to become no longer obvious when system design is developed and its complexity increased. As a consequence, the network owner, often the local energy company, is in need of a simulation program to have the possibility of analysing network behaviour and expand the understanding about the operation of district heating system. In this paper, a simulation tool developed in MATLAB/Simulink is applied in order to analyse the flow distribution in the district heating network of the town of Kiruna (Sweden). The network in Kiruna has been developing since the 60s and is today a complex network with a meshed structure, i.e. it is formed by a set of loops from which secondary branches depart. The simulation tool is part of a methodology that has specifically been developed to analyse the flow pattern in such kind of networks without altering their physical structure, and it is expected to be a valuable tool for the redesign of the network in the forthcoming relocation of some of the urban districts. The results about the current network configuration show that only a few pipes in the network are exceeding the levels of heat flow recommended by pipe manufacturers. The largest drops in pressure and temperature from the heat production site to the nodes serving the main consumer areas are within 1.2 bar and 9 °C in the days of highest demand.

Ort, förlag, år, upplaga, sidor
Elsevier, 2016
Nationell ämneskategori
Energiteknik
Forskningsämne
Energiteknik
Identifikatorer
urn:nbn:se:ltu:diva-5877 (URN)10.1016/j.enconman.2016.05.060 (DOI)000379632600006 ()2-s2.0-84971268010 (Scopus ID)411b63db-cfe4-4756-852e-77f5593f749f (Lokalt ID)411b63db-cfe4-4756-852e-77f5593f749f (Arkivnummer)411b63db-cfe4-4756-852e-77f5593f749f (OAI)
Anmärkning

Validerad; 2016; Nivå 2; 20160530 (andbra)

Tillgänglig från: 2016-09-29 Skapad: 2016-09-29 Senast uppdaterad: 2026-02-16Bibliografiskt granskad
Vesterlund, M. & Dahl, J. (2015). A method for the simulation and optimization of district heating systems with meshed networks (ed.). Energy Conversion and Management, 89, 555-567
Öppna denna publikation i ny flik eller fönster >>A method for the simulation and optimization of district heating systems with meshed networks
2015 (Engelska)Ingår i: Energy Conversion and Management, ISSN 0196-8904, E-ISSN 1879-2227, Vol. 89, s. 555-567Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

There are two main methods nowadays for modeling district heating systems, but a key disadvantage of both is that a real network containing loops cannot be described without artificial simplifications in order to eliminate those distinguishing features. However, loops are very common in mature networks that have developed a meshed structure, and make the distribution of mass and heat flows quite characteristic. For this reason, a new process integration method for modeling complex district heating systems containing loops is described in this paper. This method makes it possible to analyze how loops and bottlenecks affect the behavior of the network, as well as the distribution path of the thermal energy in it. The district heating system in the town of Kiruna (located in the north of Sweden) has a complex design with several loops and part of it is used in the paper as an example of application.

Nationell ämneskategori
Energiteknik
Forskningsämne
Energiteknik
Identifikatorer
urn:nbn:se:ltu:diva-9152 (URN)10.1016/j.enconman.2014.10.002 (DOI)000346552200053 ()2-s2.0-84908374425 (Scopus ID)7b800504-b27d-4e1c-ba92-dcf3a103f468 (Lokalt ID)7b800504-b27d-4e1c-ba92-dcf3a103f468 (Arkivnummer)7b800504-b27d-4e1c-ba92-dcf3a103f468 (OAI)
Anmärkning
Validerad; 2015; Nivå 2; 20141029 (andbra)Tillgänglig från: 2016-09-29 Skapad: 2016-09-29 Senast uppdaterad: 2026-02-16Bibliografiskt granskad
Risberg, D., Vesterlund, M., Westerlund, L. & Dahl, J. (2015). CFD simulation and evaluation of different heating systems installed in low energy building located in sub-arctic climate (ed.). Building and Environment, 89, 160-169
Öppna denna publikation i ny flik eller fönster >>CFD simulation and evaluation of different heating systems installed in low energy building located in sub-arctic climate
2015 (Engelska)Ingår i: Building and Environment, ISSN 0360-1323, E-ISSN 1873-684X, Vol. 89, s. 160-169Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Computational Fluid Dynamics (CFD) simulations were used to study the indoor climate in a low energy building in northern Sweden. The building’s low heat requirement raise the prospect of using a relatively simple and inexpensive heating system to maintain an acceptable indoor environment, even in the face of extremely low outdoor temperature. To explore the viability of this approach, the indoor climate in the building was studied considering three different heating systems: a floor heating system, air heating through the ventilation system and an air heat pump installation with one fan coil unit. The floor heating system provided the most uniform operative temperature distribution and was the only heating system that fully satisfied the recommendations to achieve tolerable indoor climate set by the Swedish authorities. On the contrary, air heating and the air heat pump created a relatively uneven distribution of air velocities and temperatures, and none of them fulfills the specified recommendations. From the economic point of view, the air heat pump system was cheaper to be installed but produced a less pleasant indoor environment than the other investigated heating systems.

Nationell ämneskategori
Energiteknik
Forskningsämne
Energiteknik
Identifikatorer
urn:nbn:se:ltu:diva-11144 (URN)10.1016/j.buildenv.2015.02.024 (DOI)000364440600014 ()2-s2.0-84924737867 (Scopus ID)a0dde22a-a36f-4f00-a108-d848722aa479 (Lokalt ID)a0dde22a-a36f-4f00-a108-d848722aa479 (Arkivnummer)a0dde22a-a36f-4f00-a108-d848722aa479 (OAI)
Anmärkning
Validerad; 2015; Nivå 2; 20150305 (andbra)Tillgänglig från: 2016-09-29 Skapad: 2016-09-29 Senast uppdaterad: 2026-02-16Bibliografiskt granskad
Vesterlund, M., Toffolo, A. & Dahl, J. (2015). Simulation and analysis of a meshed district heating network (ed.). In: (Ed.), ECOS 2015: 28th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems. Paper presented at International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems : 29/06/2015 - 03/07/2015. International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems
Öppna denna publikation i ny flik eller fönster >>Simulation and analysis of a meshed district heating network
2015 (Engelska)Ingår i: ECOS 2015: 28th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems, International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems , 2015Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

The maturity of a district heating system can be estimated from its complexity. In fact, a mature network has a meshed structure while a younger network is often in the form of small network islands or has a tree structure. When a district heating system is developing and its complexity is increasing the flow distribution in the network is no longer obvious. As a consequence, the network owner, often the local energy company, is in need of a simulation program to have the possibility of analysing it and enlarge their network understanding. In this paper, a simulation tool developed in MATLAB/Simulink is applied in order to analyse the flow distribution in the district heating network of the town of Kiruna (Sweden). The Kiruna network has been developing since the 60s and is today a mature network with the meshed structure. The method has specifically been developed to analyse the flow pattern in such kind of networks without altering their physical structure, and it is expected to be a valuable tool for the redesign of the network in the forthcoming relocation of some of the urban districts. The results about the current network configuration show that only a few pipes in the network are exceeding the recommended level of flow in terms of thermal power. The temperature and pressure drop from heat production site to the nodes serving the main consumer areas is within 1.6 bar and 10°C in the days of highest demand.

Ort, förlag, år, upplaga, sidor
International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems, 2015
Nyckelord
District heating, Meshed network, Simulation, Flow pattern, Heat distribution
Nationell ämneskategori
Energiteknik
Forskningsämne
Energiteknik
Identifikatorer
urn:nbn:se:ltu:diva-35687 (URN)2-s2.0-84978906340 (Scopus ID)a55e3550-6ae9-4a4b-a498-54300fcc8a7a (Lokalt ID)9782955553909 (ISBN)a55e3550-6ae9-4a4b-a498-54300fcc8a7a (Arkivnummer)a55e3550-6ae9-4a4b-a498-54300fcc8a7a (OAI)
Konferens
International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems : 29/06/2015 - 03/07/2015
Anmärkning

Godkänd; 2015; 20150604 (matves)

Tillgänglig från: 2016-09-30 Skapad: 2016-09-30 Senast uppdaterad: 2026-02-16Bibliografiskt granskad
Risberg, D., Vesterlund, M., Risberg, M., Hedström, A., Dahl, J. & Westerlund, L. (2014). Hållbara, integrerade energi- och VA-system (ed.). Luleå: Luleå tekniska universitet
Öppna denna publikation i ny flik eller fönster >>Hållbara, integrerade energi- och VA-system
Visa övriga...
2014 (Svenska)Rapport (Övrigt vetenskapligt)
Ort, förlag, år, upplaga, sidor
Luleå: Luleå tekniska universitet, 2014. s. 30
Serie
Rapportserie Attract ; 2014:04
Nationell ämneskategori
Energiteknik Vattenteknik
Forskningsämne
Energiteknik; VA-teknik
Identifikatorer
urn:nbn:se:ltu:diva-23505 (URN)73e3908f-5847-4f04-af09-6f9adbcefebe (Lokalt ID)978-91-7583-284-5 (ISBN)978-91-7583-285-2 (ISBN)73e3908f-5847-4f04-af09-6f9adbcefebe (Arkivnummer)73e3908f-5847-4f04-af09-6f9adbcefebe (OAI)
Anmärkning
Godkänd; 2014; 20150326 (danris)Tillgänglig från: 2016-09-29 Skapad: 2016-09-29 Senast uppdaterad: 2026-02-16Bibliografiskt granskad
Organisationer

Sök vidare i DiVA

Visa alla publikationer