Publikationer (10 of 59) Visa alla publikationer
Ljunggren, F., Fredriksson, M., Johansson, N. & Sasic Kalagasidis, A. (2026). Cross-laminated timber: a state-of-the-art review of moisture, fire, acoustics, and energy-related aspects. Wood Material Science & Engineering, 21(2), 1224-1246
Öppna denna publikation i ny flik eller fönster >>Cross-laminated timber: a state-of-the-art review of moisture, fire, acoustics, and energy-related aspects
2026 (Engelska)Ingår i: Wood Material Science & Engineering, ISSN 1748-0272, E-ISSN 1748-0280, Vol. 21, nr 2, s. 1224-1246Artikel, forskningsöversikt (Refereegranskat) Published
Abstract [en]

The increasing use of cross-laminated timber (CLT) in construction has encouraged research on moisture, fire, acoustics, and energy performance. These areas are crucial for CLT buildings’ functionality and durability and are typically addressed together during design. This study reviewed current knowledge, identifies gaps and explores synergies and conflicts among these areas, while briefly addressing the environmental impact of CLT buildings. Key findings include that airtightness is critical but often overlooked, making field and lab measurements essential. Junctions between CLT elements pose challenges in modeling sound and vibration transfer, and water absorption and removal, necessitating further research on junction robustness. More attention should be given to CLT's limited thermal mass and its impact on overheating risks, cooling demands, and fire development. Enhanced ventilation has a limited impact on off-gassing of volatile organic compounds. Covering CLT panels may be beneficial for energy efficiency, fire safety, and acoustics. Environmental impact assessments of buildings are complex and often neglect operational technical aspects. The aspects identified here are crucial for extending the service life of CLT buildings and enabling the reuse of CLT elements in circular economy value chains. Methodological innovations are needed to enhance evaluation flexibility across entire value chains.

Ort, förlag, år, upplaga, sidor
Taylor & Francis Group, 2026
Nyckelord
CLT, mass timber, building physics, hygrothermal performance, fire safety, building acoustics
Nationell ämneskategori
Husbyggnad Materialteknik
Forskningsämne
Teknisk akustik
Identifikatorer
urn:nbn:se:ltu:diva-113407 (URN)10.1080/17480272.2025.2507145 (DOI)001502977200001 ()2-s2.0-105007538164 (Scopus ID)
Anmärkning

Full text license: CC BY 4.0

Tillgänglig från: 2025-06-16 Skapad: 2025-06-16 Senast uppdaterad: 2026-08-27Bibliografiskt granskad
Baqir, M. F., Andersson, L., Bohman, A., Ljunggren, F., Kim, J.-G. & Persson, P. (2026). Reusable machine-learning substructure for efficient dynamic analysis of cross-laminated timber assemblies. Computers & structures, 333, Article ID 108499.
Öppna denna publikation i ny flik eller fönster >>Reusable machine-learning substructure for efficient dynamic analysis of cross-laminated timber assemblies
Visa övriga...
2026 (Engelska)Ingår i: Computers & structures, ISSN 0045-7949, E-ISSN 1879-2243, Vol. 333, artikel-id 108499Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Rapid vibration assessment is needed to evaluate timber assemblies across material and design variants. However, conventional computational models remain costly for repeated reanalysis because wood’s natural variability and component-geometry changes require new component-level dynamic calculations. This paper extends data-driven dynamic substructuring (DDDS) by learning a reusable machine-learning (ML) substructure for cross-laminated timber (CLT) panels. Finite-element models of sixteen tested CLT panels are calibrated against modal measurements, and the calibrated properties are expanded to 1000 material realisations using log-normal fitting and Latin hypercube sampling. A deep neural network (DNN), trained for four panel geometries, predicts the complex-valued condensed dynamic stiffness matrix of a CLT panel over 1–300 Hz, which is coupled with finite-element column substructures through standard interface equations. Predicted responses for single-floor, two-floor, and multi-floor assemblies closely match FE–FE references. In five-floor benchmarks, the FE–ML procedure is faster than both the FE–FE analysis and Craig-Bampton reduction in the cases examined, with computational savings that depend on the problem size and increase with panel size, supporting efficient screening of timber assembly designs.

Ort, förlag, år, upplaga, sidor
Elsevier Ltd, 2026
Nyckelord
Timber structures, Data-driven dynamic substructuring, Condensed dynamic stiffness, Cross-laminated timber (CLT), Reduced-order modelling, Machine learning
Nationell ämneskategori
Husbyggnad
Forskningsämne
Byggkonstruktion
Identifikatorer
urn:nbn:se:ltu:diva-120541 (URN)10.1016/j.compstruc.2026.108499 (DOI)001923153400001 ()2-s2.0-105055154457 (Scopus ID)
Forskningsfinansiär
Forskningsrådet FormasStiftelsen för internationalisering av högre utbildning och forskning (STINT)
Anmärkning

Funder: National Research Foundationof Korea (RS-2024-00350389);

Tillgänglig från: 2026-11-13 Skapad: 2026-11-13 Senast uppdaterad: 2026-11-13Bibliografiskt granskad
Bohman, A., Andersson, L., Persson, K., Ljunggren, F. & Persson, P. (2026). Vibration reduction in cross-laminated timber panels using various lamination materials and integrated elastomer layers. Journal of Building Engineering, 118, Article ID 115037.
Öppna denna publikation i ny flik eller fönster >>Vibration reduction in cross-laminated timber panels using various lamination materials and integrated elastomer layers
Visa övriga...
2026 (Engelska)Ingår i: Journal of Building Engineering, ISSN 2352-7102, Vol. 118, artikel-id 115037Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Cross-laminated timber (CLT) is increasingly used for construction of multi-storey buildings. However, ensuring satisfactory vibro-acoustic performance, particularly in the low-frequency range (typically below 200 Hz), remains a significant challenge, often necessitating add-on solutions such as floating floors. In this study, the aim was to investigate how vibration levels for CLT panels can be reduced by using various lamination materials as well as integrated elastomer layers. Finite element (FE) models were developed, calibrated and validated based on experimental modal analysis of CLT panels with and without elastomer layers. Specifically, elastic moduli of spruce, birch and compressed spruce were calibrated to experimentally obtained eigenfrequencies and mode shapes. Moreover, calibrated FE models of selected panels were used to determine and calibrate a viscoelastic material model for the elastomer layer using frequency-dependent stiffnesses and damping. Using the material model for the numerical simulations, the deviations in accelerance root mean square values were less than 1 dB compared to the experimental data. Finally, it was shown that by using birch or compressed spruce instead of spruce the vibration response could be reduced by 30% and 50%, respectively, for a realistic floor panel size. By integrating a 12 mm elastomer layer into the panels, the vibration response could be reduced by an additional 40%, compared to a panel without an elastomer layer.

Ort, förlag, år, upplaga, sidor
Elsevier, 2026
Nyckelord
Cross-laminated timber, Experimental modal analysis, Numerical vibration analysis, Lamination materials, Elastomer layer
Nationell ämneskategori
Husbyggnad
Forskningsämne
Byggkonstruktion
Identifikatorer
urn:nbn:se:ltu:diva-116058 (URN)10.1016/j.jobe.2025.115037 (DOI)001657083300001 ()2-s2.0-105027543366 (Scopus ID)
Forskningsfinansiär
VinnovaForskningsrådet FormasÅForsk (Ångpanneföreningens Forskningsstiftelse)
Anmärkning

Full text license: CC BY 4.0;

Funder: Södra Foundation for Research, Development and Education;

Tillgänglig från: 2026-01-19 Skapad: 2026-01-19 Senast uppdaterad: 2026-06-30Bibliografiskt granskad
Ljunggren, F. (2023). Innovative solutions to improved sound insulation of CLT floors. Developments in the Built Environment, 13, Article ID 100117.
Öppna denna publikation i ny flik eller fönster >>Innovative solutions to improved sound insulation of CLT floors
2023 (Engelska)Ingår i: Developments in the Built Environment, E-ISSN 2666-1659, Vol. 13, artikel-id 100117Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Building with cross laminated timber (CLT) has gain increased interest over the last years, but in common to other wood-based building systems, inadequate low-frequency sound insulation is seen as a problem. This paper deals with two methods to improve the sound insulation of CLT panels, normally made from spruce: 1) heavy CLT, introducing compressed, i.e. densified, spruce as well as alternative wood species, and 2) elastic layer based upon shear motion. In addition to a series of laboratory measurements, a full-scale CLT floor made of two 60 mm birch panels with a 12 mm elastic layer in between was tested in a two-room test mock-up. The results from the acoustical measurements showed that the floor has about 7 dB greater airborne and impact sound insulation for one-third octave bands, 50–3150 Hz, compared to a standard CLT floor of the same total height.

Ort, förlag, år, upplaga, sidor
Elsevier Ltd, 2023
Nyckelord
Compressed wood, Cross laminated timber, Impact sound, Low frequencies, Sound insulation
Nationell ämneskategori
Strömningsmekanik Trävetenskap
Forskningsämne
Teknisk akustik
Identifikatorer
urn:nbn:se:ltu:diva-95293 (URN)10.1016/j.dibe.2022.100117 (DOI)001025951000001 ()2-s2.0-85145965700 (Scopus ID)
Forskningsfinansiär
Energimyndigheten, 46771–1
Anmärkning

Validerad;2023;Nivå 2;2023-02-03 (sofila)

Tillgänglig från: 2023-02-03 Skapad: 2023-02-03 Senast uppdaterad: 2025-10-21Bibliografiskt granskad
Ljunggren, F. & Simmons, C. (2023). Sound insulation in multi-family houses: Proposal of single number limits for acoustical protection and comfort. Building Acoustics, 30(4), 387-407
Öppna denna publikation i ny flik eller fönster >>Sound insulation in multi-family houses: Proposal of single number limits for acoustical protection and comfort
2023 (Engelska)Ingår i: Building Acoustics, ISSN 1351-010X, Vol. 30, nr 4, s. 387-407Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

In this paper, the acoustical quality in apartment housing is studied. The purpose is to find out to what extent occupants are annoyed by indoor noise and to compare the annoyance with measured airborne and impact sound insulation. The occupants in 38 building cases in Sweden, grouped into different construction categories, were asked in a questionnaire to rate their annoyance for a variety of potentially disturbing sound sources. In total, 1230 individual responses were used for the statistical analyses. The result shows that on average, the occupants are quite satisfied and reported low annoyance. This is taken as an indication that the present National legislation for sound insulation, airborne sound insulation included, works well. However, annoyance from footstep of walking neighbours is an exception, causing significantly greater annoyance compared to any other source, especially among occupants in lightweight buildings. The commonly used impact sound insulation descriptors are unable to match subjective experience. In combination with the sensitivity of lightweight floors to low-frequency sounds, improper building designs are likely to result in poor noise protection for the occupants. To overcome this issue, a new single number quantity taking frequencies as low as 25 Hz into account is suggested.

Ort, förlag, år, upplaga, sidor
Sage Publications, 2023
Nyckelord
Acoustic indoor quality, footstep annoyance, lightweight buildings, low frequencies, single number quantity, sound insulation
Nationell ämneskategori
Strömningsmekanik
Forskningsämne
Teknisk akustik
Identifikatorer
urn:nbn:se:ltu:diva-102424 (URN)10.1177/1351010X231206077 (DOI)001090843400001 ()2-s2.0-85175476740 (Scopus ID)
Forskningsfinansiär
Forskningsrådet Formas, 2018-01084Energimyndigheten, 46771-1
Anmärkning

Validerad;2023;Nivå 2;2023-11-14 (sofila);

Full text license: CC BY

Tillgänglig från: 2023-11-13 Skapad: 2023-11-13 Senast uppdaterad: 2025-10-21Bibliografiskt granskad
Ljunggren, F. & Simmons, C. (2022). Correlation between sound insulation and occupant's€™ perception: Proposal of alternative single number rating of impact sound, Part III. Applied Acoustics, 197, Article ID 108955.
Öppna denna publikation i ny flik eller fönster >>Correlation between sound insulation and occupant's€™ perception: Proposal of alternative single number rating of impact sound, Part III
2022 (Engelska)Ingår i: Applied Acoustics, ISSN 0003-682X, E-ISSN 1872-910X, Vol. 197, artikel-id 108955Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Through a series of Swedish research projects carried out over twelve years, the relation between the measured impact sound insulation and the corresponding subjective rating given by residents of multi-storey apartment buildings has been studied. Previous results, based on a limited number of building cases, suggested the need to include frequencies below 50 Hz in a frequency weighted single number quantity to get a reasonable correlation with the subjective ratings.

The purpose of this paper is to include an extended amount of data compared to the previous studies to secure more substantiated results. Data has been examined for 38 building cases, including a variety of lightweight and heavy constructions. More than 1200 questionnaire responses form the basis for comprehensive statistical analyses.

The results confirm the conclusions of the previous parts (I, II), stating that frequencies below 50 Hz are of importance when evaluating impact sound insulation, primarily in lightweight buildings. The correlation between measured weighted single number quantities and annoyance ratings increases significantly when the frequency range is extended down to 25 Hz. The strongest correlation was obtained when evaluating the impact sound insulation, again from 25 Hz, when using the weighted single number quantity LnT,w + CI,25€-2500 where the CI-term is evaluated according to ISO 717-2 amended to the extended frequency range 25-€“2500 Hz. It is also suggested that in the lowest one-third octave bands, 25-40 Hz, there is no need to normalize the impact sound pressure levels with respect to the reverberation time.

Ort, förlag, år, upplaga, sidor
Elsevier, 2022
Nyckelord
Impact sound insulation, Low frequencies, Lightweight buildings, Footstep annoyance, Subjective perception, Single number quantity
Nationell ämneskategori
Strömningsmekanik Freds- och konfliktforskning Övrig annan samhällsvetenskap
Forskningsämne
Teknisk akustik
Identifikatorer
urn:nbn:se:ltu:diva-92407 (URN)10.1016/j.apacoust.2022.108955 (DOI)000844031600004 ()2-s2.0-85135370475 (Scopus ID)
Forskningsfinansiär
Forskningsrådet FormasEnergimyndigheten
Anmärkning

Validerad;2022;Nivå 2;2022-11-18 (hanlid)

Tillgänglig från: 2022-08-17 Skapad: 2022-08-17 Senast uppdaterad: 2025-10-21Bibliografiskt granskad
Ljunggren, F. (2022). Sound insulation, residents’ satisfaction, and design of wooden residential buildings. In: Flemming Christensen, Rodrigo Ordoñez (Ed.), Proceedings of the Euroregio / BNAM2022: . Paper presented at Euroregio/BNAM2022, Aalborg, Denmark, May 9-11, 2022 (pp. 269-278). European Acoustics Association (EAA)
Öppna denna publikation i ny flik eller fönster >>Sound insulation, residents’ satisfaction, and design of wooden residential buildings
2022 (Engelska)Ingår i: Proceedings of the Euroregio / BNAM2022 / [ed] Flemming Christensen, Rodrigo Ordoñez, European Acoustics Association (EAA), 2022, s. 269-278Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Wood-based multi-family houses continue to gain popularity. Related to acoustics, low-frequency sound insulation as well as appropriate single number quantities for the evaluation of sound insulation have been in focus for a long time. In a series of Swedish research projects running for 12 years, the correlation between rated annoyance from residents and measured airborne and impact sound insulation, with alternative frequency ranges and weightings, have been studied. In total, 38 building cases of various constructions were involved and more than 1200 questionnaire responses were collected. While the building code’s present evaluation parameter for airborne sound insulation, D'nT,w + C50–3150, seems to be working well, the situation is different with respect to impact sound insulation. L'nT,w as well as L'nT,w + CI,50–2500 show weak correlation with the rated annoyance from the residents. The reason is that frequencies below 50 Hz are overlooked, although they dominate the response from walking in many common, particularly lightweight, floor constructions. The strongest correlation with the rated annoyance from impact sound, including both lightweight and heavyweight constructions, was found when the measured frequency range was extended down to 25 Hz, using L'nT,w + CI,25–2500. Because footstep noise rendered the highest degree of annoyance in the survey, a somewhat more restricted requirement than what it used today is suggested to offer a higher degree of protection against unwanted impact sounds. It is a delicate challenge to design wood-based floor constructions with great sound insulation at low frequencies to meet the higher requirement. A tested innovative floor design based upon two high-density cross-laminated timber plates with an intermediate damping layer may serve as the basis for future constructions. 

Ort, förlag, år, upplaga, sidor
European Acoustics Association (EAA), 2022
Nyckelord
sound insulation, impact sound, residents’ annoyance, single number quantity, wooden floor design
Nationell ämneskategori
Strömningsmekanik
Forskningsämne
Teknisk akustik
Identifikatorer
urn:nbn:se:ltu:diva-92706 (URN)
Konferens
Euroregio/BNAM2022, Aalborg, Denmark, May 9-11, 2022
Forskningsfinansiär
Forskningsrådet FormasEnergimyndigheten
Anmärkning

ISBN för värdpublikation:  978-87-995400-5-1

Tillgänglig från: 2022-08-30 Skapad: 2022-08-30 Senast uppdaterad: 2025-10-21Bibliografiskt granskad
Pettersson, M., Ljunggren, F. & Simmons, C. (2022). The effect of furniture when measuring reverberation times at low frequencies from 31.5 Hz. Building and Environment, 223, Article ID 109480.
Öppna denna publikation i ny flik eller fönster >>The effect of furniture when measuring reverberation times at low frequencies from 31.5 Hz
2022 (Engelska)Ingår i: Building and Environment, ISSN 0360-1323, E-ISSN 1873-684X, Vol. 223, artikel-id 109480Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

When evaluating impact sound insulation of dwellings, including frequencies below 50 Hz has been reported to improve the correlation between the measurements and the occupants’ rating of annoyance from footstep noise. To determine the impact sound insulation, the reverberation time of the receiving room must be considered, a procedure that may introduce large errors at low frequencies. If it can be shown that normal furniture does not affect the absorption (and thereby neither the reverberation time), the reverberation time below 50 Hz could be omitted in the evaluation of impact sound insulation. This would improve the measurement accuracy of the impact sound insulation and simplify the measurement procedure. The purpose of this paper is to investigate to what extent fully furnished rooms for residential purposes affect the reverberation time. Measurements are conducted using the integrated impulse response method in two empty and furnished bedrooms of different construction. Due to the potential errors in the reverberation time measurement, sound pressure level was measured for comparison. No statistically significant absorption difference due to furniture could be found at frequencies below 50 Hz, neither for the measured reverberation times nor the difference in sound pressure level. As a consequence, impact sound insulation may be evaluated without any reverberation measurement below 50 Hz.

Ort, förlag, år, upplaga, sidor
Elsevier, 2022
Nyckelord
Reverberation time, Integrated impulse response method, Low frequencies, Impact sound insulation
Nationell ämneskategori
Strömningsmekanik
Forskningsämne
Teknisk akustik
Identifikatorer
urn:nbn:se:ltu:diva-92524 (URN)10.1016/j.buildenv.2022.109480 (DOI)000848550100002 ()2-s2.0-85136147235 (Scopus ID)
Forskningsfinansiär
Forskningsrådet Formas, 2018-01084
Anmärkning

Validerad;2022;Nivå 2;2022-09-09 (joosat);

Tillgänglig från: 2022-08-17 Skapad: 2022-08-17 Senast uppdaterad: 2025-10-21Bibliografiskt granskad
Ljunggren, F., Simmons, C. & Pettersson, M. (2022). Uncertainty of in situ low frequency reverberation time measurements from 20 Hz – An empirical study; Part II: Impulse response method. Noise Control Engineering Journal, 70(3), 298-308
Öppna denna publikation i ny flik eller fönster >>Uncertainty of in situ low frequency reverberation time measurements from 20 Hz – An empirical study; Part II: Impulse response method
2022 (Engelska)Ingår i: Noise Control Engineering Journal, ISSN 0736-2501, E-ISSN 2168-8710, Vol. 70, nr 3, s. 298-308Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

An important part of evaluating impact sound insulation is to measure the reverberation time in the receiving room. The increasing trend of using wooden structures for residential buildings has made it increasingly important to have control of the measurement procedure at low frequencies. The present ISO standards do not give any specific guidelines for how to deal with frequencies below 50 Hz. It cannot be taken for granted that the present guidelines developed for higher frequencies are also appropriate for lower frequencies. This paper includes an empirical study of the spatial variation of reverberation time, measured from 20 Hz in two different rooms, with about 100 microphone positions in each room. The results from two alternative methods are compared, based upon the impulse response and the interrupted noise respectively. The accuracy of an intended normal measurement procedure is estimated with respect to the number of microphone positions.

Ort, förlag, år, upplaga, sidor
Institute of Noise Control Engineering, 2022
Nationell ämneskategori
Strömningsmekanik
Forskningsämne
Teknisk akustik
Identifikatorer
urn:nbn:se:ltu:diva-92516 (URN)10.3397/1/377024 (DOI)000810206700007 ()2-s2.0-85132897345 (Scopus ID)
Forskningsfinansiär
Forskningsrådet Formas
Anmärkning

Validerad;2022;Nivå 2;2022-11-18 (hanlid)

Tillgänglig från: 2022-08-17 Skapad: 2022-08-17 Senast uppdaterad: 2025-10-21Bibliografiskt granskad
Ljunggren, F. (2020). AkuTimber tackles the low frequency impact sound insulation issue. In: Proceedings of the FA2020 Conference: . Paper presented at Forum Acusticum 2020, Lyon, France [Virtual], December 7-11, 2020 (pp. 1627-1629). European Acoustics Association (EAA)
Öppna denna publikation i ny flik eller fönster >>AkuTimber tackles the low frequency impact sound insulation issue
2020 (Engelska)Ingår i: Proceedings of the FA2020 Conference, European Acoustics Association (EAA), 2020, s. 1627-1629Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

AkuTimber is the joint name for two research projects carried out at Luleå University of Technology 2019-2021. The projects focus upon low frequency sound insulation, which has been pointed out to suffer from high annoyance among the residents of timber houses. One of the main objectives is to find a single number quantity that in a better way, compared to established quantities of today, describes the relation between impact sound measurement and perception. The goal of the study is to include up to 40 building objects in total, including field measurements from 20 Hz as well as questionnaires, although this interim report will not be able to cover them all. The correlation between the residents reported annoyance from impact sound and various number single number quantities of different frequency range is presented for as many building objects as are ready up to bow.

Ort, förlag, år, upplaga, sidor
European Acoustics Association (EAA), 2020
Nyckelord
sound insulation, impact sound, residents’ annoyance, single number quantity, wooden floor design
Nationell ämneskategori
Arkitekturteknik
Forskningsämne
Teknisk akustik
Identifikatorer
urn:nbn:se:ltu:diva-92588 (URN)10.48465/fa.2020.0922 (DOI)
Konferens
Forum Acusticum 2020, Lyon, France [Virtual], December 7-11, 2020
Forskningsfinansiär
Forskningsrådet Formas, 2018-01084Energimyndigheten, 46771-1
Tillgänglig från: 2022-08-19 Skapad: 2022-08-19 Senast uppdaterad: 2025-10-21Bibliografiskt granskad
Organisationer
Identifikatorer
ORCID-id: ORCID iD iconorcid.org/0000-0002-8451-4804

Sök vidare i DiVA

Visa alla publikationer