Change search
Link to record
Permanent link

Direct link
Publications (8 of 8) Show all publications
Andrén, A., Dahlström, L.-O. & Nordlund, E. (2023). Field Observations of Water and Ice Problems in Railway Tunnels from a Maintenance Perspective. Journal of Earth Sciences and Geotechnical Engineering, 13(1), 11-54
Open this publication in new window or tab >>Field Observations of Water and Ice Problems in Railway Tunnels from a Maintenance Perspective
2023 (English)In: Journal of Earth Sciences and Geotechnical Engineering, ISSN 1792-9040, E-ISSN 1792-9660, Vol. 13, no 1, p. 11-54Article in journal (Refereed) Published
Abstract [en]

During the winter season, ice causes major problems in many Swedish railway tunnels. Ice, rock and shotcrete in the roof and on the walls may come loose and fall down, installations and cables can break due to ice loads and the tracks can become covered with ice. To maintain safety and prevent traffic disturbances, many tunnels require frequent maintenance. The removal of ice, loose rock and shotcrete is expensive and potentially risky work for the maintenance workers. To reduce maintenance costs, it is important to improve our knowledge of frost penetration inside tunnels and investigate the effect of ice pressure and frost shattering on loadbearing constructions. The aim of this investigation was to gather information about the problems caused by water leakage and its effect on the degradation of a rock tunnel when subjected to freezing temperatures. There are many factors that determine whether frost or ice formations will appear in tunnels. To collect information on ice formation problems, field observations were undertaken in five of Sweden’s railway tunnels between autumn 2004 and summer 2005. For one of the tunnels, follow-up observations also took place in March during the years 2005, 2006 and 2007.

Place, publisher, year, edition, pages
Scientific Press International Limited, 2023
Keywords
Railway tunnel, Field observations, Ice formation, Frost shattering, Maintenance, Degradation of rock and shotcrete, Cold climate
National Category
Other Social Sciences Mineral and Mine Engineering Infrastructure Engineering
Research subject
Mining and Rock Engineering
Identifiers
urn:nbn:se:ltu:diva-96357 (URN)10.47260/jesge/1312 (DOI)
Funder
Swedish Transport AdministrationSwedish Research Council FormasRock Engineering Research Foundation (BeFo)
Note

Validerad;2023;Nivå 1;2023-04-11 (hanlid);

Licens full text: Scientific Press International as Publisher applies the Creative Commons Attribution License (CCAL) to all works we publish. Under the CCAL, authors retain ownership of the copyright for their article, but authors allow anyone to download, reuse, reprint, modify, distribute, and/or copy articles in Scientific Press International journals, so long as the original authors and source are cited. No permission is required from the authors or the publishers.

Available from: 2023-04-11 Created: 2023-04-11 Last updated: 2025-10-21Bibliographically approved
Andrén, A. (2023). Freezing Temperature Flows in Railway Tunnels and its Consequence on the Rock Supporting Structure, the Rock and the Reinforcing Elements. (Doctoral dissertation). Luleå: Luleå University of Technology
Open this publication in new window or tab >>Freezing Temperature Flows in Railway Tunnels and its Consequence on the Rock Supporting Structure, the Rock and the Reinforcing Elements
2023 (English)Doctoral thesis, comprehensive summary (Other academic)
Alternative title[sv]
Temperaturflöden i järnvägstunnlar och dess konsekvens på det bärande systemet, berget och de förstärkande elementen
Abstract [en]

Water in the surrounding rock mass flows into the tunnel via naturally occurring joints and via cracks caused by the blasting used to excavate the tunnel. The most common method in Sweden to reduce or prevent leakage problems are first and foremost the use of grouting. However, experience shows that despite extensive pre-grouting and supplementary post-grouting, it is difficult to seal the rock mass so that drips and moisture are completely eliminated. Although the water itself causes degradation of the tunnel, the degradation process increases dramatically when the water is exposed to freezing temperatures. Water expands during freezing and due to water migration, which occurs in rock in a similar way as in soil, the ice causes frost shattering of the interface between rock and shotcrete and also to the shotcrete and the rock itself. This can damage the main load-bearing system. The ice formation itself is a maintenance problem, as the tunnels must be kept clear of icicles, ice pillars and ice layers in the tracks or on the roads. One of the main tasks in this research project has been to identify which problems cause the most maintenance work and where and when these problems occur in the tunnel.

During the field observations carried out as part of this doctoral study, many problems with water and ice were discovered, all of which contribute to increased maintenance. Many ice problems are directly linked to frost insulated drain mats. Leakage and ice formations occur at the edge of the drains, in mat splices and when brackets for cable racks, handrails or other installations puncture a drain and it has not been properly sealed. In drains covered with shotcrete, frost shattering and cracking in the shotcrete can be a problem. Frost cycles in the tunnel cause the water to freeze and thaw alternately, allowing more water to reach the freezing area due to water migration, resulting in frost shattering of the rock and the shotcrete. If not anchored with bolts, the reinforcing effect and the stability of shotcrete in a tunnel is dependent on the adhesion to the rock surface. It is, therefore, important to take all available measures to ensure good adhesion. Poor adhesion in itself is not a degradation problem, but a void can form in the interface between rock and shotcrete as a result of poor adhesion. If this void is filled with water that cannot drain away, ice pressure can occur in the layer between rock and shotcrete. The ice pressure can cause cracking and degradation of the shotcrete if the pressure exceeds the tensile strength of the adjacent material. In some of the reported fall-outs of rock and shotcrete, an ice layer was discovered between the rock surface and the edges of the remaining shotcrete layer. Therefore, frost shattering is a likely cause of the fall-outs. Many frost cycles combined with water leakage can cause frost shattering. The field measurements conducted as a part of the doctoral study have shown that most frost cycles do not occur closest to the tunnel entrances, but instead about 100 to 200 m into the longer tunnels. The results from the laboratory tests performed as part of the doctoral study showed that the adhesive strength between rock and shotcrete decreased significantly when the test panels were subjected to freeze-thaw cycles. Furthermore, more of the micro seismic events (AE - acoustic emission monitoring) occurred in the test panels that had access to water during freezing. Therefor, maintenance personnel and inspectors should pay particular attention to water leakage in sections that have an increased number of frost cycles, to avoid future problems with frost shattering of rock or shotcrete. 

In the longer tunnels studied in this work, a greater number of ice formations occurred in the inner parts of the tunnel, than close to the entrances. The rock mass emits heat, which heats up the cold outside air that enters the tunnel. Due to the heat transfer from the rock mass, leakage points located further along the tunnels can remain unfrozen. A leak that is closer to the tunnel entrances in the longer tunnels or a leak in a shorter tunnel are exposed to higher freezing rates. The entire rock mass freezes and the leak ‘freezes dry’, that is, ice forms in the water-bearing fracture, preventing further water leakage.

Where and when ice problems occur along a tunnel depends on many factors. Besides the obvious water leakage, the length of frost penetration into the tunnel is the main reason for where and when ice problems occur. The predominant cause of frost penetration in most of the tunnels is the thermally induced airflow. In the longer tunnels, the inclination of the tunnel affects frost penetration the most. The field observations showed that there was a difference in where and when leakage points appear during the year and also in terms of variation in the amount of leakage water. There was also a variation over different years. The conclusions of the field observations are that it is difficult to estimate where the insulated drain mats should be located along a tunnel. Based on experience from this survey, the location of the drains should be determined only after several inspections and especially after a winter period, when the main problems with ice formation occur. Previous perception regarding ice problems have been that ice formation only occurs at the tunnel entrances and in the outer parts of the tunnel. A proposed measure has, therefore, been to cover the first 300 m from each entrance with frost insulated drains to try to completely eliminate the ice problems. However, this is not an effective solution to the problem. The insulation not only prevents the cold from reaching the leakage point, but it also prevents the rock mass from emitting heat that warms up the cold outside air entering the tunnel. Thus, the frost can penetrate further into the tunnel and the problems with ice formation are only moved further into the tunnel. As the amount and location of the frost insulation affects frost penetration, the dimensioning of insulation must, therefore, be carried out in several iterations, where each new distribution of insulation along the tunnel is calculated separately.

For the tunnels that have been studied as part of this doctoral study, the following has emerged. The central and southern parts of Sweden have shorter cooling periods and the tunnels are exposed to many temperature fluctuations around 0°C during the winter. The frost does not have time to penetrate as far here as in the tunnels in the northern parts of Sweden. Therefore, more ice problems arise around the entrances of the tunnels in the southern parts of Sweden than for those in the northern parts. For northern parts of Sweden, the problem of growing ice formations in sections near the tunnel entrance usually occurs only during the autumn and spring, but not in winter. The field observations showed that the problems with ice growth and temperature fluctuations around 0°C occur further along the longer tunnels in the northern parts of Sweden. This is because the temperature of the tunnel air is higher due to heat transfer from the rock mass. For shorter tunnels that adopt the same temperatures as the outside air, ice formations can occur along the entire length of the tunnel in the sections that have leakage problems. The Swedish Transport Administration’s regulations are currently being updated and the observations and measurements carried out in this doctoral work are now being used to evaluate new requirements regarding frost penetration in tunnels.

Abstract [sv]

Vatten i den omgivande bergmassan rinner in i tunneln via naturligt förekommande sprickor och via sprickor orsakade av själva sprängningen av tunneln. Den vanligaste metoden i Sverige för att minska eller förebygga läckageproblem är först och främst injektering. Erfarenheter visar dock att trots omfattande förinjektering och kompletterande efterinjektering, är det svårt att täta bergmassan så att dropp och fukt helt elimineras. Även om vattnet i sig orsakar nedbrytning av tunneln, ökar nedbrytningsprocessen dramatiskt när vattnet utsätts för minusgrader. Vattnet expanderar vid frysning och på grund av vattenvandring, som sker i berg på liknande sätt som i jord, kan isen orsaka frostsprängning i skiktet mellan sprutbetong och berg, men även i själva sprutbetongen och berget. Detta kan skada det bärande huvudsystemet. Själva isbildningen är ett underhållsproblem i sig, eftersom tunnlarna måste hållas fria från istappar, ispelare och islager i spår eller på vägar. En av uppgifterna i forskningsprojektet har varit att ta reda på vilka problem som orsakar mest underhållsarbete och var och när dessa problem uppstår i tunneln.

Vid fältobservationerna utförda inom ramen för detta doktorsarbete observerades många problem med vatten och is, som alla bidrar till ett ökat underhåll. Många isproblem är direkt kopplade till de frostisolerade dränmattorna. Läckage och isbildning uppstår vid dränkanterna, i skarvar mellan mattor och när fästen för kabelräcken, ledstänger eller andra installationer punkterar dränen som sedan inte har blivit ordentligt tätad. I dräner täckta med sprutbetong kan frostsprängning och sprickbildning i sprutbetongen vara ett problem. Frostcykler i tunneln gör att vattnet fryser och tinar om vartannat, vilket möjliggör vattentransport till frysområdet på grund av vattenvandring med frostsprängning av berg och sprutbetong som följd. Förstärkningseffekten och stabiliteten hos sprutbetong i en tunnel är helt beroende av vidhäftningen mot bergytan. Det är därför viktigt att vidta alla tillgängliga åtgärder för att säkerställa god vidhäftning. Dålig vidhäftning i sig är inte något nedbrytningsproblem. Om ett hålrum i skiktet mellan berget och sprutbetongen fylls med vatten som inte kan dränera undan, kan ett istryck byggas upp. Istrycket kan orsaka vidhäftningsbrott i kontakten mellan sprutbetong och berg, samt sprickbildning och nedbrytning av sprutbetongen och berget om trycket överstiger draghållfastheten hos det intilliggande materialet. Vid några av de rapporterade nedfallen av berg och sprutbetong upptäcktes ett islager mellan bergytan och kanterna på det kvarvarande sprutbetongskiktet. Frostsprängning är en trolig orsak till nedfallen. Många frostcykler i kombination med vattenläckage kan orsaka frostsprängning. Utförda fältmätningar har visat att de flesta frostcykler inte sker närmast tunnelmynningarna, utan istället på cirka 100 till 200 m in längs de längre tunnlarna som studerats inom ramen för detta doktorsarbete. Resultaten från utförda laboratorieförsök, visade att vidhäftningshållfastheten mellan berg och sprutbetong minskade betydligt när testpanelerna utsattes för frys-tiningscykler. Dessutom var de registrerade mikroseismiska händelserna (AE – mätning med akustisk emission)fler i de testpaneler som hade tillgång till vatten under frysning. Därför bör vattenläckage i de sektioner som har ett ökat antal frostcykler, få extra uppmärksamhet från underhållspersonal och inspektörer, för att undvika framtida problem med frostsprängning av berg eller sprutbetong.

I de längre tunnlarna som har studerats, bildades ett större antal isformationer i de inre delarna av tunneln, jämfört med området kring mynningarna. Bergmassan avger värme som värmer upp den kalla uteluften som tränger in i tunneln. På grund av värmeöverföringen från bergmassan kan läckage som finns längre in i tunnlarna förblir ofrusna. Ett droppläckage som är närmare tunnelmynningarna i de längre tunnlarna eller droppläckage i de kortare tunnlarna utsätts för högre fryshastighet. Hela bergmassan fryser och läckaget ”fryser torrt”, det vill säga det bildas is i den vattenförande sprickan vilket förhindrar ytterligare vattenläckage.

Var och när isproblem uppstår längs en tunnel beror på många saker. Förutom det uppenbara vattenläckaget är längden på frostinträngning in längs tunneln den främsta orsaken till var och när isproblem uppstår. Den dominerande orsaken till frostinträngning är i de flesta av tunnlarna det termiskt inducerade luftflödet. I de längre tunnlarna är det lutningen på tunneln som påverkar frostinträngningen allra mest. Fältobservationerna visade att det fanns en skillnad i var och när läckageställen uppstår under året och även i fråga om variation i mängden läckagevatten. Det fanns också en variation över olika år. Slutsatserna av fältobservationerna är att det är svårt att uppskatta var de isolerade dränmattorna ska placeras längs en tunnel. Utifrån erfarenheter från denna undersökning bör dränernas placering bestämmas först efter flera inspektioner och särskilt efter en vinterperiod, då de verkliga problemen med isbildning uppstår. Tidigare funderingar kring isproblem har varit att isbildning endast sker vid tunnelmynningarna och i de yttre delarna av tunneln. Ett åtgärdsförslag har därför varit att klä in de första 300 m från vardera mynningen med frostisolerande dräner för att helt försöka eliminera problemen med isbildning. Det är inte en effektiv lösning på problemet. Isoleringen förhindrar inte bara kylan från att nå vattenläckaget, utan den hindrar även bergvärmen att komma ut i tunneln och värma upp den kalla uteluften. Därmed kan frosten tränga in längre och problemen med isbildning flyttas bara längre in längs tunneln. Då mängden och placeringen av frostisoleringen påverkar frostinträngningen, måste därför dimensioneringen av isolering utföras i flera iterationer, där varje ny fördelning av isolering längs tunneln beräknas separat.

För de tunnlar som har studerats i detta doktorsarbete har följande framkommit. De mellersta och södra delarna av Sverige har kortare frostperioder och tunnlarna utsätts för många temperaturväxlingar kring 0°C under vintern. Frosten hinner inte tränga in lika långt här, som i tunnlarna i de norra delarna av Sverige. Därför uppstår fler isproblem kring tunnlarnas mynningar i de södra delarna av Sverige, än för tunnlarna i de norra delarna. I de norra delarna av Sverige uppstår problemet med växande isformationer i sektioner nära tunnelmynningarna vanligtvis bara under hösten och våren, men inte under vintern. Fältobservationerna visade att problemen med istillväxt och temperaturväxlingar kring 0°C uppstår längre in i de längre tunnlarna i norra Sverige, eftersom tunnelluftens temperatur är högre på grund av värmetransport från bergmassan. För kortare tunnlar, som antar samma temperaturer som uteluften, kan isformationer uppstå längs hela tunnelns längd i de sektioner som har läckageproblem. Trafikverket regelverk håller på att uppdateras och de observationer och framförallt mätningar utförda i detta doktorsarbete används nu för att utvärdera nya kravställningar kring köldinträngning i tunnlar.

Place, publisher, year, edition, pages
Luleå: Luleå University of Technology, 2023
Series
Doctoral thesis / Luleå University of Technology, ISSN 1402-1544
Keywords
Tunnel, frost penetration, ice formation, freeze-thaw test, frost shattering, temperature measurement, maintenance, degradation of rock and shotcrete, cold climate, Tunnel, köldinträngning, isbildning, frystester, frostsprängning, temperaturmätning, underhåll, nedbrytning av berg och sprutbetong, kallt klimat
National Category
Geotechnical Engineering and Engineering Geology
Research subject
Mining and Rock Engineering
Identifiers
urn:nbn:se:ltu:diva-97034 (URN)978-91-8048-335-3 (ISBN)978-91-8048-336-0 (ISBN)
Public defence
2023-06-16, F1031, Luleå Tekniska Universitet, Luleå, 09:00 (Swedish)
Opponent
Supervisors
Available from: 2023-05-08 Created: 2023-05-08 Last updated: 2025-10-21Bibliographically approved
Andrén, A., Dahlström, L.-O. & Nordlund, E. (2022). Evaluation of a laboratory model test using field measurements of frost penetration in railway tunnels. Cold Regions Science and Technology, 204, Article ID 103660.
Open this publication in new window or tab >>Evaluation of a laboratory model test using field measurements of frost penetration in railway tunnels
2022 (English)In: Cold Regions Science and Technology, ISSN 0165-232X, E-ISSN 1872-7441, Vol. 204, article id 103660Article in journal (Refereed) Published
Abstract [en]

Despite extensive grouting efforts to prevent water from leaking into tunnels, water seepages remain. When exposed to freezing temperatures, ice formations occur. During the winter, the Swedish Transport Administration's railway tunnels are affected by major problems caused by ice, such as icicles from roof and walls, ice loads on installations, ice-covered tracks and roads, etc. To ensure safety and prevent traffic disruptions, many tunnels require extensive maintenance. Improved knowledge about frost penetration in tunnels is required to reduce maintenance of the tunnels. Frost insulated drain mats are often used at leakage spots to prevent ice formation along the tunnels. To find out which parts of a tunnel are exposed to freezing temperatures, the University of Gävle and the Royal Institute of Technology in Stockholm conducted a laboratory model test on behalf of the Swedish National Rail Administration (now the Swedish Transport Administration). The laboratory model test aimed to find a method to determine the expected temperature conditions along a tunnel to decide which parts of the tunnel require frost insulation to protect the drainage system from freezing and prevent ice formation. To evaluate the laboratory model test, the Swedish Transport Administration in collaboration with Luleå University of Technology have performed field surveys in two Swedish railway tunnels. The field measurements involved monitoring temperatures in air, rock surfaces and rock mass, as well as measuring wind direction, wind and air velocity and air pressure. The measurements in the tunnels show that the frost penetrates further into the tunnels than was expected from the laboratory model test, which was based on a completely uninsulated tunnel. Frost insulated drains do not only prevent the cold air from reaching the rock mass, but also prevent the rock from emitting geothermal heat that warms up the cold tunnel air. Consequently, the frost penetrates further into the tunnel than it would do if the heat from the rock mass was allowed to warm up the outside air on its way into the tunnel. The number of frost insulated drains and how much of the tunnel walls and roof are covered thereby affect the length of the frost penetration.

Place, publisher, year, edition, pages
Elsevier, 2022
Keywords
Frost penetration, Frost shattering, Temperature measurement, Maintenance, Railway tunnels
National Category
Mineral and Mine Engineering Geotechnical Engineering and Engineering Geology Other Civil Engineering
Research subject
Mining and Rock Engineering
Identifiers
urn:nbn:se:ltu:diva-92959 (URN)10.1016/j.coldregions.2022.103660 (DOI)000854045800001 ()2-s2.0-85137023905 (Scopus ID)
Funder
Swedish Transport AdministrationSwedish Research Council FormasRock Engineering Research Foundation (BeFo)
Note

Validerad;2022;Nivå 2;2022-09-12 (joosat);

Licens fulltext: CC BY License

Available from: 2022-09-12 Created: 2022-09-12 Last updated: 2025-10-21Bibliographically approved
Andrén, A., Dahlström, L.-O. & Nordlund, E. (2020). Degradation of the Reinforcing Effect of Shotcrete: Freeze-Thaw Tests on Shotcrete-Rock Panels. The Electronic journal of geotechnical engineering, 25(1), 1-30
Open this publication in new window or tab >>Degradation of the Reinforcing Effect of Shotcrete: Freeze-Thaw Tests on Shotcrete-Rock Panels
2020 (English)In: The Electronic journal of geotechnical engineering, ISSN 1089-3032, E-ISSN 1089-3032, Vol. 25, no 1, p. 1-30Article in journal (Refereed) Published
Abstract [en]

In rock tunnels in regions with colder climates, the load-bearing structure, including the rock and the reinforcing elements, is exposed to repeated destructive freezing and thawing cycles during the winter. If water accumulates in cracks or in the interface between rock and shotcrete, frost shattering may occur. If there is adequate adhesion between the rock and shotcrete, degradation of the shotcrete as a reinforcement element due to frost shattering should not present a problem. However, if adhesion is poor, a small void will form between the rock and the shotcrete where water can accumulate. If the water in these voids is subjected to freeze-thaw cycles, ice will develop, thus exerting pressure on the interface and causing the shotcrete to crack and degrade. In tunnel sections with complex water conditions, for example, relatively water-bearing open joints and weak zones, the adhesion of the shotcrete and its stability and reinforcing effect may be strongly affected when exposed to freezing temperatures. This article describes a laboratory study that comprised freeze-thaw tests on shotcreterock panels with the objective of studying how water migration affects the growth of ice and the ice pressure in the shotcrete-rock interface to better understand the degradation of the reinforcing effect of shotcrete

Place, publisher, year, edition, pages
Mete Öner, 2020
Keywords
Freeze-thaw test, frost shattering, tunnel, degradation of shotcrete, cold climate
National Category
Mineral and Mine Engineering
Research subject
Mining and Rock Engineering
Identifiers
urn:nbn:se:ltu:diva-81719 (URN)000608581500001 ()
Note

Validerad;2020;Nivå 1;2020-11-30 (alebob)

Available from: 2020-11-30 Created: 2020-11-30 Last updated: 2025-10-22Bibliographically approved
Andrén, A., Dahlström, L.-O. & Nordlund, E. (2020). Temperature Flows in Railway Tunnels: Field Measurements of Frost Penetration. Journal of Earth Sciences and Geotechnical Engineering, 10(5), 161-194
Open this publication in new window or tab >>Temperature Flows in Railway Tunnels: Field Measurements of Frost Penetration
2020 (English)In: Journal of Earth Sciences and Geotechnical Engineering, ISSN 1792-9040, E-ISSN 1792-9660, Vol. 10, no 5, p. 161-194Article in journal (Refereed) Published
Abstract [en]

Even though extensive pre-grouting is carried out during the construction of tunnels, certain leakages and drips remain. These remaining leakages are remedied by a combination of post-injection and drainage measures with, for example, frost insulated drain mats, whose function is to prevent the cold tunnel air from reaching a leakage spot and causing water to freeze. Despite these measures, some water may still enter the tunnels and cause problems during winter with ice formations and frost shattering. Icicles, ice pillars and ice-covered roads and railway tracks require constant maintenance. If ice occurs in the fracture network close to the tunnel contour or in the interface between the rock and shotcrete, it can cause degradation of the load-bearing capacity of the tunnel and fall-outs of both materials. In tunnel sections with water leakage problems it is common to protect the load-bearing structure from freezing with insulated drainage systems. To determine where along the tunnel efforts must be made to prevent ice formation, the temperature conditions of tunnels must be investigated. This article presents parts of the results from field measurements in two Swedish railway tunnels. The measurements involves monitoring of air and rock temperatures, air pressure and air velocity.

Place, publisher, year, edition, pages
Scientific Press International Limited, 2020
Keywords
Frost penetration, ice formation, frost shattering, temperature measurement, maintenance, railway tunnel
National Category
Mineral and Mine Engineering
Research subject
Mining and Rock Engineering
Identifiers
urn:nbn:se:ltu:diva-81720 (URN)
Note

Validerad;2020;Nivå 1;2020-11-30 (alebob)

Available from: 2020-11-30 Created: 2020-11-30 Last updated: 2025-10-22Bibliographically approved
Andrén, A. & Dahlström, L.-O. (2011). Temperaturflöden i järnvägstunnlar – Glödberget (ed.). Luleå: Luleå tekniska universitet
Open this publication in new window or tab >>Temperaturflöden i järnvägstunnlar – Glödberget
2011 (Swedish)Report (Other academic)
Abstract [en]

During the winter ice is causing major problems in several of the Swedish Transport administrations railway tunnels. Freezing water is forming icicles and pillars that can fall down at track, and grow so large that they intrude on the clearance gauge. Lighting equipment and cables can be broken because of the ice load and tracks can become cowered with ice Periodic freezing can cause frost shattering and this process can cause fall-outs of rock and shotcrete. In order to maintain safety and prevent traffic disruption, many tunnels requiring extensive maintenance. In order to reduce maintenance of the tunnels, improved knowledge about frost penetration and the effects of ice pressure on the load-bearing capacity of the tunnel is required. 2002 the University of Gävle and KTH performed a model study to determine the temperature conditions in tunnels. To verify the model study field measurements are carried out in collaboration between the Transport Administration and Luleå University of Technology. This technical report describes the tests conducted so far in the Glödberget tunnel at Nyåker, 80 km south-west of Umeå. Measurements show that the developed models underestimate the frost penetration. Although the tunnel is 1680 meters long, the frost penetrates the entire length of the tunnel even if the temperature outside the tunnel is just a few degrees below zero. A contributing factor to why the field measurements and model do not conform can be that the model study is based on a completely uninsulated tunnel. In the Glödberget tunnel a large part of the walls and roof are covered the frost insulated drains. The function of the frost insulated drains is to prevent the cold tunnel air from reaching a leakage point and causing water to turn into ice. However, the insulation does not only prevent the cold air from reaching the rock, but also prevents the heat from the rock mass from entering the tunnel and warming up the cold tunnel air. Consequently, the frost penetrates further into the tunnel than it would do if the heat from the rock mass were allowed to warm up the outside air on its way into the tunnel. The amount of frost insulated drains and how much of the tunnel walls and roof that are covered are thereby affecting the length of the frost penetration. Temperature measurements has been carried out down into the ballast bed. To eliminate the risks with freezing drainage water, the drainage pipes are located at a depth of 2 m under the level of the rails. Measurements show that the temperature does not penetrate as far down as earlier feared and the depth of the pipes in the middle parts of the tunnel could be made shallower, with respect to risk of frost. Temperature measurements behind a frost insulated drain in the middle of the track tunnel, has shown that drains are able to smooth out the temperature changes that occur in the tunnel air. But when the temperature is negative for a longer period, the temperature behind the drain drops below 0ºC. Then the drainage ability is reduced due to icing and it can cause frost damage to the drain. Measurements of air temperature in the adjacent service tunnel shows how frost penetration is affected by air movement. The service tunnel is closed with gates at both ends. When the air in a tunnel is not exposed to movement, it is heated by geothermal heat and adopt the same temperature as the rock. Rock temperatures usually coincide with the average annual temperature applicable to the area where the tunnel is located. For the Glödberget tunnel there is a very good agreement between the average annual temperature for the area and the measurements performed in the service tunnel.

Abstract [sv]

Under vinterhalvåret orsakar is stora problem i flera av Trafikverkets järnvägstunnlar. Vatten som fryser bildar istappar och svallis som kan fall ned i spår samt växa till sådan storlek att de inkräktar på det ”fria rummet” som tågen kräver för att passera genom tunneln. Belysningsarmaturer och kablar bryts sönder på grund av islast och spåren blir isbelagda på grund av takdropp och svallisbildning. Återkommande frysperioder medför att berg och sprutbetong i tak och väggar kan lossna och falla ner. För att upprätthålla säkerheten och förhindra trafikstörningar kräver många tunnlar omfattande underhållsinsatser. För att kunna reducera underhållet i tunnlarna, krävs förbättrad kunskap kring köldinträngning och effekterna av istryck på det bärande huvudsystemet. 2002 utförde Högskolan i Gävle och KTH en modellstudie för att bestämma temperatur-förhållanden i tunnlar. För att verifiera modellstudien genomförs nu mätningar i fält och projektet utförs i ett samarbete mellan Trafikverket och Luleå Tekniska Universitet. Denna Tekniska rapport redovisar de mätningar som hittills utförts i Glödbergstunneln vid Nyåker som ligger 8 mil sydväst om Umeå. Mätningarna visar att framtagna modeller underskattar köldinträngningen. Trots att tunneln är 1680 m lång, sker köldinträngning i hela tunnelns längd även vid några få minusgrader utanför tunneln. En bidragande orsak till att fältmätningarna och modellen inte överensstämmer kan vara att modellstudien bygger på en helt oisolerad tunnel. I Glödbergstunneln finns en stor del frostisolerande dräner uppsatta. De frostisolerande dränernas funktion är att förhindra att inläckande vatten fryser till is, men isoleringen förhindrar inte bara kylan att tränga in till läckaget, den hindrar även bergvärmen från att komma ut i tunneln och värma upp den kalla uteluften. Isoleringen möjliggör för kylan att tränga längre in i tunneln än vad den skulle ha gjort i fall bergvärmen gavs möjlighet att värma upp den kalla uteluften på dess väg in längs tunneln. Mängden frostisolerande dräner och hur stor del av tunnels vägg- och takyta som är inklädd, täckningsgraden, påverkar därmed köldinträngningens längd. Mätningar av temperaturer har utförts ned i ballasten. Glödbergstunneln har en undersprängning på 2 m under RUK, med motiveringen att ledningar för exempelvis dräneringsvatten ska vara förlagda på frostfritt djup. Mätningarna visar att temperaturen inte tränger så långt ned som man tidigare befarat och undersprängning i de mittersta delarna av tunneln hade kunnat göras mindre, med avseende på frostrisken. Temperaturmätningarna bakom en frostisolerad drän i mitten av spårtunneln, har visat att dränen klarar av att jämna ut de temperaturväxlingar som sker i tunnelluften utanför dränen. Men då temperaturen är negativ under en längre period kryper även temperaturen bakom dränen under 0 C och då förhindras dräneringsmöjligheten på grund av isbildning och det kan orsaka frostsprängning av dränen. Mätningar av lufttemperatur i den intilliggande servicetunneln visar tydligt hur köldinträngningen påverkas av luftrörelser. Servicetunneln är stängd med portar mot både ute- och tunnelluft. När luften i en tunnel inte utsätts för rörelse, värms den upp av bergvärmen och antar samma temperatur som berget har. Bergtemperaturen brukar oftast sammanfalla men den årsmedeltemperatur som gäller för den plats där tunneln är belägen. För Glödbergstunneln stämmer detta mycket bra överens med de utförda mätningarna i servicetunneln. Sökord: köldinträngning, istryck, frostsprängning, temperaturmätning, underhåll, järnvägstunnel.

Place, publisher, year, edition, pages
Luleå: Luleå tekniska universitet, 2011. p. 44
Series
Technical report / Luleå University of Technology, ISSN 1402-1536
Keywords
köldinträngning, istryck, frostsprängning, temperaturmätning, underhåll, järnvägstunnel
National Category
Other Civil Engineering
Research subject
Mining and Rock Engineering
Identifiers
urn:nbn:se:ltu:diva-24933 (URN)d1bd0794-0035-4424-a6e1-d6721f471eb6 (Local ID)978-91-7439-318-7 (ISBN)d1bd0794-0035-4424-a6e1-d6721f471eb6 (Archive number)d1bd0794-0035-4424-a6e1-d6721f471eb6 (OAI)
Note

Godkänd; 2011; 20110829 (andren)

Available from: 2016-09-29 Created: 2016-09-29 Last updated: 2025-10-21Bibliographically approved
Andrén, A. (2009). Degradation of rock and shotcrete due to ice pressure and frost shattering (ed.). (Licentiate dissertation). Luleå: Luleå tekniska universitet
Open this publication in new window or tab >>Degradation of rock and shotcrete due to ice pressure and frost shattering
2009 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

In recent years the Swedish Rail Administration has observed an increased incidence of shotcrete and rock fall-outs in its tunnels, for which reason it has initiated several research projects, of which the present project entitled "Degradation of rock and shotcrete due to ice pressure and frost shattering" is one. The aim of this licentiate project was to bring together experience and information relating to ice formation and the effect of ice pressure on fault zones, cracks and, in particular, the shotcrete/rock interface. Furthermore, the hypothesis from the literature review is tested and the results of the laboratory tests are presented.When water freezes, a 9 % volumetric expansion occurs according to the phase transition into ice. This can exert a pressure on the adjacent material. If this ice pressure exceeds the tensile strength of the adjacent material or the adhesive strength of the shotcrete/rock interface, the material will be damaged. The degree of damage depends, among other factors, on the degree of saturation of the material. A partially saturated material can resist breakage despite its low tensile strength, because ice expansion and pore-water distribution can occur in pores which were initially filled with air. A fully saturated material however yields to frost action regardless of its tensile strength, because it has none of the free space this expansion requires.Volumetric expansion is not the only cause of frost shattering and research shows that the frost action in rocks is the same as in soils, when the rock has access to water during freezing. In soil, water is drawn towards the frozen fringe and causes ice lenses to grow. In a similar manner water tends to migrate in rock and causes ice bodies to grow inside pores and cracks. This water migration takes place because a thin film of adsorbed water occurs at the surface of mineral particles and it is in this water film that water is able to migrate towards the frozen zones. Experimental work has shown that a considerable amount of adsorbed water remains unfrozen at sub-zero temperatures not only in soils, but also in rocks, which enable water migration.Water migration and ice growth thus depend not only on access to water and freezing temperatures, but also on the duration of these temperatures and the freezing rate. If rock or shotcrete is subjected to rapid freezing, the thickness of the water film is quickly reduced and the water migration is inhibited, which limits frost damages to rock and shotcrete. By contrast, a slow freezing allows water migration to occur over a longer period, which can result in greater frost damage to rock and shotcrete. The field investigations found changes to the freezing periods as well as their duration to be of major importance to ice formation growth. If the freezing period was of long duration, several of the cracks and the leakage spots freeze. If leakage is subjected instead to short periods of freezing and thawing, the water in the crack will never freeze and will continue to leak, resulting in ice formation growth. In cold areas, such as the north of Sweden, this problem takes place even far inside the tunnels. This phenomenon occurs because the leakage water transports heat from the rock mass to the cold tunnel wall. The heat content of the water keeps the rock around the crack opening from freezing despite sub-zero tunnel air temperatures. Hence, the leakage spot will continue to leak, until a certain temperature and temperature duration is achieved, which results in ice formations when the water meets the cold tunnel air. Another experience in the field investigations was that the rock and shotcrete fall-outs often occurred in areas with leakage problems.The results of the laboratory tests performed in this licentiate project also show that water in combination with freezing temperature can cause degradation problems. The tensile tests undertaken, showed that the adhesive strength decreased about 50 % when the shotcrete/rock samples had been subjected to freeze-thaw cycles. Furthermore, acoustic emission measurements (AE) showed that more events took place when the shotcrete/rock panels had access to free water during freezing. The literature review, field investigations of railway tunnels and the laboratory tests shows that access to water during freezing can cause damage to the shotcrete/rock interface. This confirms the hypothesis that shotcrete and rock fall-outs can occur because ice pressure in a crack or at the interface exceeds the tensile strength of the material or the adhesive strength between rock and shotcrete. One thing that the laboratory tests failed to provide a satisfactory answer to, was whether these fall-outs could occur due to widening of an initially small area of poor adhesion around a rock crack opening. However, the laboratory test showed a lot of activity during freezing in those areas prepared with poor adhesion. It thus it appears that small areas of poor adhesion in some way affect deterioration of the adhesive strength of the shotcrete/rock interface.

Abstract [sv]

Nedbrytning av berg och sprutbetong på grund av istryck och frostsprängningPå senare år har Banverket märkt en ökning av inrapporterade nedfall av berg och sprutbetong i sina järnvägstunnlar. I och med detta så startades en rad forskningsprojekt kring problemen med vattenläckage och isbildning i tunnlar. Detta projekt "Nedbrytning av berg och sprutbetong på grund av istryck och frostsprängning" är ett av dessa. Syftet med detta licentiatprojekt var att samla erfarenhet och information om hur is bildas samt hur istryck påverkar krosszoner, sprickor och framför allt skiktet mellan berg och sprutbetong. Vidare testas hypotesen från litteraturstudien och resultaten från laborationsförsök redovisas.När vatten fryser till is sker en 9 % volymsutvidgning och denna expansion kan orsaka att ett tryck uppstår mot det omgivande materialet. Det omgivande materialet kommer att utsättas för brott om trycket från isen överstiger materialets draghållfasthet eller vidhäftningshållfasthet i skiktet mellan berg och sprutbetong. Storleken på skadan är bland annat beroende av materialets vattenmättnad. Ett delvis vattenmättat material kan klara sig från brott, trots att dess draghållfasthet är låg, genom att expansionen av isen och omfördelning av porvatten kan ske i de porer som från början var fyllda med luft. Ett helt vattenmättat material ger istället efter för frostsprängningen oberoende av sin draghållfasthet, på grund av att materialet inte har något fritt utrymme som kan ta upp expansionen.Det är inte bara isens volymsutvidgningen som orsakar frostsprängning. Forskning visar att om berg har tillgång till fritt vatten under nedkylningen sker en process som liknar den i jord, där vatten vandrar fram mot frysfronten och bildar islinser. På ett liknande sätt vandrar vatten i berg och orsakar tillväxt av isskikt i exempelvis en por eller spricka, vilket kan orsaka att istrycket ökar. Vattenvandringen sker på grund av att det finns en tunn vattenfilm av adsorberat vatten längs mineralkornens ytor och i denna vattenfilm finns möjlighet för vatten att vandra mot frysfronten. Experimentellt arbete har visat att en betydande del av det adsorberade vattnet förblir ofruset vid negativa temperaturer, inte bara i jord utan även i berg och detta möjliggör vattenvandringen.Vattenvandring och istillväxt är inte bara beroende av tillgången till vatten och frystemperatur, utan även av fryshastighet och varaktighet av köldgrader. Om berg och sprutbetong utsätts för snabb nedkylning minskar vattenfilmens tjocklek och vattenvandringen förhindras, vilket begränsar frostsprängningen av materialet. Om istället berget kyls ned långsamt, tillåts vattenvandringen att ske under en längre period, vilket kan resultera i större frostsprängning. I de utförda fältundersökningarna visade det sig att varaktigheten och förändring av frysperioderna var av stor vikt för tillväxten av isformationer. Om frysperioden hade lång varaktighet frös vissa av sprickorna och läckagepunkterna. Om läckagen istället utsattes för kortare perioder av frysning och tining frös aldrig sprickorna och vatten fortsatte att läcka med växande isformationer som följd. För kalla områden, som i de norra delarna av Sverige, uppstår dessa problem även långt in i tunnlarna. Problemen uppstår på grund av att läckagevatten transporterar fram värme från bergmassan till den kalla tunnelytan. Värmen från läckagevattnet håller bergmassan kring spricköppningen ofrusen trots att tunnelluften är kall. Därför fortsätter sprickan att föra fram vatten med konsekvensen att det bildas is när vattnet väl kommer ut i den kalla tunnelluften. En annan erfarenhet från fältundersökningarna var att utfallen av berg och sprutbetong ofta förekom i sektioner som hade problem med vattenläckage.Resultaten från laborationsförsöken utförda i det här licentiatprojektet visar också att vatten i kombination med negativa temperaturer kan orsaka nedbrytningsproblem. De utförda dragtesterna visade att vidhäftnings-hållfastheten minskar med ungefär 50 % när sprutbetong/bergproverna hade utsatts för frysning. Vidare visade mätningarna av akustisk emission (AE) att fler AE-händelser skedde när sprutbetong/bergproverna hade tillgång till vatten under frysningen. Litteraturstudien, fältundersökningarna i järnvägstunnlarna och laborationsförsöken pekar på att tillgången på vatten under frysning kan orsaka skador på skiktet mellan berg och sprutbetong. Detta bekräftar hypotesen att utfall av berg och sprutbetong kan uppstå på grund av att istryck i en spricka eller i skiktet mellan berg och sprutbetong överskrider draghållfastheten för materialet eller vidhäftningshållfastheten mellan berg och sprutbetong. En sak som laborationsförsöken inte kunde ge ett bra svar på var ifall utfallen kunde ske på grund av spridning av en liten yta som redan från början hade dålig vidhäftning runt en spricköppning. Men försöken visade att det förekom mycket aktivitet under frysningen i de områden som preparerats med dålig vidhäftning. Så det verkar som att små områden med dålig vidhäftning kan påverkar försämringen av vidhäftningen mellan berg och sprutbetong.

Place, publisher, year, edition, pages
Luleå: Luleå tekniska universitet, 2009. p. 143
Series
Licentiate thesis / Luleå University of Technology, ISSN 1402-1757
National Category
Other Civil Engineering
Research subject
Mining and Rock Engineering
Identifiers
urn:nbn:se:ltu:diva-18722 (URN)a0055a90-2407-11de-a401-000ea68e967b (Local ID)978-91-86233-31-0 (ISBN)a0055a90-2407-11de-a401-000ea68e967b (Archive number)a0055a90-2407-11de-a401-000ea68e967b (OAI)
Presentation
2009-05-05, Banverket i Borlänge, videosändning till F1031 vid Luleå tekniska universitet, Banverket, Borlänge, Borlänge, 13:00
Available from: 2016-09-29 Created: 2016-09-29 Last updated: 2025-10-21Bibliographically approved
Andrén, A. & Dahlström, L.-O. (2008). Temperaturflöden i järnvägstunnlar och konsekvenser för drift och underhåll (ed.). In: (Ed.), Bergmekanikdag: föredrag vid Bergmekanikdag i Stockholm 10 mars 2008. Paper presented at Bergmekanikdag 2008 : 10/03/2008 - 10/03/2008. Stiftelsen bergteknisk forskning - Befo
Open this publication in new window or tab >>Temperaturflöden i järnvägstunnlar och konsekvenser för drift och underhåll
2008 (Swedish)In: Bergmekanikdag: föredrag vid Bergmekanikdag i Stockholm 10 mars 2008, Stiftelsen bergteknisk forskning - Befo , 2008Conference paper, Published paper (Other academic)
Place, publisher, year, edition, pages
Stiftelsen bergteknisk forskning - Befo, 2008
National Category
Other Civil Engineering
Research subject
Mining and Rock Engineering
Identifiers
urn:nbn:se:ltu:diva-30274 (URN)40907580-7995-11dd-b356-000ea68e967b (Local ID)40907580-7995-11dd-b356-000ea68e967b (Archive number)40907580-7995-11dd-b356-000ea68e967b (OAI)
Conference
Bergmekanikdag 2008 : 10/03/2008 - 10/03/2008
Note

Godkänd; 2008; 20080903 (ysko)

Available from: 2016-09-30 Created: 2016-09-30 Last updated: 2023-09-05Bibliographically approved
Organisations
Identifiers
ORCID iD: ORCID iD iconorcid.org/0000-0002-1083-3968

Search in DiVA

Show all publications