Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Influence from bends on a pressure-time measurement
Norwegian University of Science and Technology (NTNU), Trondheim.
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Strömningslära och experimentell mekanik.
Norwegian University of Science and Technology (NTNU), Trondheim.
2010 (engelsk)Inngår i: 25th IAHR Symposium on Hydraulic Machinery and Systems :: 20-24 September 2010 'Politehnica' University of Timişoara, Timişoara, Romania, London: IOP Publishing Ltd , 2010Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

One of the criteria for using the pressure-time method is that there is a straight pipe between the measurement cross sections. If the physical influences from a bend were known the method could be expanded for use over bends and hence on more power plants. At the Norwegian University of Science and Technology (NTNU) a test rig suited for experiments on the pressure-time method has been built. In addition to earlier experiments performed on straight pipe and double 90 degree bend, experiments on double 45 degree bend has been performed. This is done in order to try to find out if there is a clear relationship between bend geometry and its influence on the pressure time curve. To further develop the knowledge a full scale test in the field has been conducted on a 5 MW 58 meter head machine with a vertical penstock and a 90 degree bend. In the laboratory a double 90 degree bend caused an underestimation of the flow of about 1 % compared to a straight pipe, while for a double 45 degree bend a conclusion can not be found as the spread around the mean and uncertainty bands is within the range for the straight pipe. The field measurements with a 90 degree bend showed that the underestimation became 8.5%. When measuring pressure difference over bends the resulting calculation will give an underestimation of the flow. This should imply that the measured transient pressure is damped. (Regardless if this is the correct term it is here chosen to call this damping.) The question is if the damping is caused by friction or kinetic effects. The rapid deceleration of the water masses will give transient friction. How transient friction behaves is a topic of interest in hydraulic research. Bends will also cause skewed velocity and pressure profile on inlet and outlet of the bend as well as secondary flows. How this affects the transient pressure is also an interesting parameter.

sted, utgiver, år, opplag, sider
London: IOP Publishing Ltd , 2010.
Serie
I O P Conference Series: Earth and Environment, ISSN 1755-1307 ; 1
HSV kategori
Forskningsprogram
Strömningslära
Identifikatorer
URN: urn:nbn:se:ltu:diva-37664DOI: 10.1088/1755-1315/12/1/012078ISI: 000325657000078Lokal ID: bbff2650-f19b-11df-8b36-000ea68e967bOAI: oai:DiVA.org:ltu-37664DiVA, id: diva2:1011162
Konferanse
IAHR Symposium on Hydraulic Machinery and Systems : 20/09/2010 - 24/09/2010
Merknad
Validerad; 2010; 20101116 (ponjon)Tilgjengelig fra: 2016-10-03 Laget: 2016-10-03 Sist oppdatert: 2025-10-22bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Person

Jonsson, Pontus

Søk i DiVA

Av forfatter/redaktør
Jonsson, Pontus
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 65 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf