Towards Energy Smart Data Centers: Simulation of Server Room Cooling System
Luleå tekniska universitet, Institutionen för system- och rymdteknik, Datavetenskap.ORCID-id: 0000-0002-0799-2888
Luleå tekniska universitet, Institutionen för system- och rymdteknik, Datavetenskap.ORCID-id: 0000-0002-9315-9920
Luleå tekniska universitet, Institutionen för system- och rymdteknik, Datavetenskap.ORCID-id: 0000-0001-8185-7118
ABB AB, Corporate research.ORCID-id: 0000-0003-2353-0752
Rekke forfattare: 42015 (engelsk)Inngår i: Proceedings of 2015 IEEE 20th International Conference on Emerging Technologies & Factory Automation (ETFA 2015): Luxembourg, 8-11 Sept. 2015, Piscataway, NJ: IEEE Communications Society, 2015, artikkel-id 7301573Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Cooling is an extremely important process in modern data centers. Cooling systems of server rooms ensure appropriate operation conditions to IT systems, such as servers and data storage, but, on the other side, they consume a lot of energy. Current control systems, which are installed in data centers and are responsible for thermal management of the facilities, are following conservative control strategies that maintain constant thermal conditions irrespective of computer load and outside temperature, thus efficient use of energy has not been appropriately addressed by them. In this paper, a method of optimizing energy consumption while maintaining an acceptable level of thermal comfort for CPUs in the server room is proposed.In the proposed method, a behavioral thermal model for serverroom should be created first, and then thermal behavior of theserver room would be simulated under different circumstancesusing its thermal model, in order to find an optimum controlstrategy capable of retaining balance between thermal comfortand efficient use of energy. The effectiveness of the proposedmethod has been investigated via simulating a typical serverroom using MATLAB and SIMULINK and the results aredemonstrated.

sted, utgiver, år, opplag, sider
Piscataway, NJ: IEEE Communications Society, 2015. artikkel-id 7301573
Serie
I E E E International Conference on Emerging Technologies and Factory Automation. Proceedings, ISSN 1946-0740
HSV kategori
Forskningsprogram
Kommunikations- och beräkningssystem
Identifikatorer
URN: urn:nbn:se:ltu:diva-39442DOI: 10.1109/ETFA.2015.7301573Scopus ID: 2-s2.0-84952920349Lokal ID: e3588fda-c025-4cf9-9264-8efa8c16d3bfISBN: 978-1-4673-7929-8 (digital)OAI: oai:DiVA.org:ltu-39442DiVA, id: diva2:1012955
Konferanse
IEEE International Conference on Emerging Technologies and Factory Automation : 08/09/2015 - 11/09/2015
Merknad

Validerad; 2016; Nivå 1; 20151026 (arader)

Tilgjengelig fra: 2016-10-03 Laget: 2016-10-03 Sist oppdatert: 2025-10-22bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Mousavi, ArashVyatkin, ValeriyBerezovskaya, YuliaZhang, Xiaojing

Søk i DiVA

Av forfatter/redaktør
Mousavi, ArashVyatkin, ValeriyBerezovskaya, YuliaZhang, Xiaojing
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 312 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf