Bedömning av tre in-line fuktkvotsmätare för trä
2011 (engelsk)Independent thesis Advanced level (professional degree), 20 poäng / 30 hpOppgave
Abstract [en]

The vision of wood as an engineering material and a first choice in buildings, constructions and furniture production put high demands on measuring equipment which can define and determine the quality of boards and planks. The moisture content in wood is a quality factor that is all too often badly described when sawn goods is delivered, but still it is an important factor in the further processing. This thesis is a part of a project, where the objective is to find or develop measuring equipment which can determine the moisture content between 7 to 18% MC with an accuracy of ±1 % (90 % confidence interval). Within the frames of this thesis, three moisture content meters for inline use where tested. A test material with five wood classes was produced. Each class included approximately twenty pieces. The intention with the wood classes was to find differences between the meters in how they handle different types of wood. Two of the equipments were tested in industry and the third in the lab. The meters were calibrated with the same material within the span 8 to 17,5 % MC. The test material was then fed through the meters and the values were logged. The results were analyzed in regard to the measuring technique or method the meter was using. According to the results, there are differences between the methods. The MC meter which is using the capacitance method shows too high values when measuring high density pieces compared to low density pieces with the same moisture content. This is a result of the nature of capacitance, which mostly depends on the amount of water and not the fraction between water and wood. The results also showed that the meter which used the shortest wavelength (microwaves) measured too high values in and around knots. The reason for this behavior is unclear, but could be explained by diffraction around the knot due to the higher density. In general, the MC meters showed good accuracy.

sted, utgiver, år, opplag, sider
2011. , s. 38
Emneord [en]
Technology
Emneord [sv]
Teknik, microwave, dielectric properties
Identifikatorer
URN: urn:nbn:se:ltu:diva-42335Lokal ID: 05b7d17b-7796-49bd-b93f-b5bbd93856f2OAI: oai:DiVA.org:ltu-42335DiVA, id: diva2:1015555
Fag / kurs
Student thesis, at least 30 credits
Utdanningsprogram
Wood Engineering, master's level
Veileder
Examiner
Merknad
Validerat; 20110402 (anonymous)Tilgjengelig fra: 2016-10-04 Laget: 2016-10-04 Sist oppdatert: 2025-10-22bibliografisk kontrollert

Open Access i DiVA

fulltekst(1570 kB)345 nedlastinger
Filinformasjon
Fil FULLTEXT02.pdfFilstørrelse 1570 kBChecksum SHA-512
667ddab148be697fdc647d06c44b24447692db682a44c5390b37ac01e56d40ec73b96185298cda4ea5c12a6c60d44aa2177452e3271b0762fd9fed2b7b42c729
Type fulltextMimetype application/pdf

Søk i DiVA

Av forfatter/redaktør
Nilsson, Martin

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 347 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 97 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf