Increasing PV hosting capacity in distorted distribution systems using passive harmonic filtering
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap.ORCID-id: 0000-0002-1819-8911
Electrical and Electronics Engineering, Balikesir University.
15th of May Higher Institute of Engineering, Mathematical and Physical Sciences, Helwan, Cairo.
College of Engineering, Design & Physical Sciences, Brunel University London.
2017 (engelsk)Inngår i: Electric power systems research, ISSN 0378-7796, E-ISSN 1873-2046, Vol. 148, s. 74-86Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Adding new capacity expansion alternatives using distributed generation (DG) technologies, particularly penetration of renewable energy, has several economical, and technical advantages such as the reduced system costs, the improved voltage profile, lower line loss and enhanced system’s reliability. However, the DG units may lead to power quality, energy efficiency, and protection problems in the system when their penetration exceeds a particular value, generally called as the system’s hosting capacity (HC) in the literature. In this paper, the HC determination of a distorted distribution system with Photovoltaic (PV)-based DG units is handled as an optimization problem by considering over and under voltage limitations of buses, current carrying capabilities of the lines, and harmonic distortion limitations as constraints. It is seen from simulation results that the HC is dramatically decreased with the increment of the load’s nonlinearity level and the utility side’s background voltage distortion. Accordingly, a C-type passive filter is designed to maximize the harmonic-constrained HC of the studied system while satisfying the constraints. The results indicate that higher HC level can be achieved using the proposed filter design approach compared to three conventional filter design approaches as voltage total harmonic distortion minimization, line loss minimization and power factor maximization.

sted, utgiver, år, opplag, sider
Elsevier, 2017. Vol. 148, s. 74-86
HSV kategori
Forskningsprogram
Elkraftteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-62940DOI: 10.1016/j.epsr.2017.03.020ISI: 000402446800008Scopus ID: 2-s2.0-85016451814OAI: oai:DiVA.org:ltu-62940DiVA, id: diva2:1087518
Merknad

Validerad; 2017; Nivå 2; 2017-04-07 (andbra)

Tilgjengelig fra: 2017-04-07 Laget: 2017-04-07 Sist oppdatert: 2025-10-22bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Sakar, Selcuk

Søk i DiVA

Av forfatter/redaktør
Sakar, Selcuk
Av organisasjonen
I samme tidsskrift
Electric power systems research

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 332 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf