Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Comparative Analysis of Transformer-Energizing and Fault-Caused Voltage Dips on the Dynamic Behavior of DFIG-Based Wind Turbines
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap.ORCID-id: 0000-0001-5845-5620
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap.
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap.ORCID-id: 0000-0003-4074-9529
Universidade Federal do Rio Grande do Sul, Porto Alegre, Brazil .
2020 (engelsk)Inngår i: 2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe), IEEE, 2020, s. 589-593Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

This work compares the response of DFIG-based wind turbines under voltage dips caused by transformer-energizing and caused by an asymmetrical fault. Voltage dips with similar retained voltage and duration and the two distinct causes are applied to an equivalent model of a DFIG-based wind park. The dips are different in terms of harmonic content and unbalance during the recovery after the dip. Due to its slow recovery, the transformer-energizing dip results in longer fluctuation in torque, longer overshoot in DC-link voltage, and longer recovery to the pre-dip active power. Also, due to its harmonic content, the harmonic distortion in the rotor and stator current is higher for the transformer-energizing dip. As the impact is different between the transformer-energizing dip and the fault-caused dip, it is recommended to consider both events separately during low-voltage-ride-through studies.

sted, utgiver, år, opplag, sider
IEEE, 2020. s. 589-593
Emneord [en]
Power Quality, Voltage Dips, DFIG, Wind Turbine, Transformer Energizing, LVRT, FRT
HSV kategori
Forskningsprogram
Elkraftteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-81462DOI: 10.1109/ISGT-Europe47291.2020.9248983ISI: 000758439100115Scopus ID: 2-s2.0-85097355455OAI: oai:DiVA.org:ltu-81462DiVA, id: diva2:1502231
Konferanse
10th IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe 2020), 26-28 October, 2020, Delft, The Netherlands (Virtual)
Merknad

ISBN för värdpublikation: 978-1-7281-7100-5

Tilgjengelig fra: 2020-11-19 Laget: 2020-11-19 Sist oppdatert: 2026-02-13bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

de Oliveira, Roger AlvesCheng, ChenBollen, Math H.J.

Søk i DiVA

Av forfatter/redaktør
de Oliveira, Roger AlvesCheng, ChenBollen, Math H.J.
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 140 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf