Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Development of a novel eccentric arm cycle ergometer for training the upper body
Avdelningen för hälsovetenskap, Mittuniversitetet, Sweden.
Avdelningen för kvalitetsteknik, maskinteknik och matematik, Mittuniversitetet, Sweden.ORCID-id: 0000-0002-9205-6807
Avdelningen för hälsovetenskap, Mittuniversitetet, Sweden.ORCID-id: 0000-0002-3814-6246
2013 (engelsk)Inngår i: Medicine & Science in Sports & Exercise, ISSN 0195-9131, E-ISSN 1530-0315, Vol. 45, nr 1, s. 206-211Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Several investigators have demonstrated that chronic eccentric leg cycling is an effective method for improving lower body neuromuscular function (e.g., quadriceps muscle size, strength, and mobility) in a variety of patient and athletic populations. To date, there are no reports of using eccentricarm cycling (ECarm) as an exercise modality, probably in large part because of the lack of commercially available ECarm ergometers. Purpose: Our purposes for conducting this study were to 1) describe the design and construction of an ECarm ergometer and 2) compare ECarm to traditional concentric arm cycling (CCarm). Methods: All of the parts of a Monark 891E cycle ergometer (Monark Exercise AB, Vansbro, Sweden) were removed, leaving the frame and flywheel. An electric motor (2.2 kW) was connected to the flywheel via a pulley and a belt. Motor speed and pedaling rate were controlled by a variable frequency drive. A power meter quantified power and pedaling rate, and provided feedback to the individual. Eight individuals performed 3-min ECarm and CCarm trials at 40, 80, and 120 W (60 rpm) while V̇O2 was measured. Results: The ECarm ergometer was simple to use, was adjustable, provided feedback on power output to the user, and allowed for a range of eccentric powers. V̇O2 during ECarm was substantially lower compared with CCarm (P < 0.001). At similar V̇O2 (0.97 ± 0.18 vs 0.91 ± 0.09 L•min, for ECarm and CCarm, respectively, P = 0.26), power absorbed during ECarm was approximately threefold greater than that produced during CCarm (118 ± 1 vs 40 ± 1 W, P < 0.001). Conclusion: This novel ECarm ergometer can be used to perform repetitive, high-force, multijoint, eccentric actions with the upper body at a low level of metabolic demand and may allow researchers and clinicians to use ECarm as a training and rehabilitation modality. © 2012 by the American College of Sports Medicine.

sted, utgiver, år, opplag, sider
Lippincott Williams & Wilkins , 2013. Vol. 45, nr 1, s. 206-211
Emneord [en]
Eccentric muscle contraction, ergometry, multijoint exercise, power, rehabilitation
HSV kategori
Identifikatorer
URN: urn:nbn:se:ltu:diva-84373DOI: 10.1249/MSS.0b013e318269c79cISI: 000312535200028PubMedID: 22843110Scopus ID: 2-s2.0-84871615327OAI: oai:DiVA.org:ltu-84373DiVA, id: diva2:1555886
Tilgjengelig fra: 2013-01-08 Laget: 2021-05-19 Sist oppdatert: 2025-10-21bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Elmer, StevenDanvind, JonasHolmberg, Hans-Christer

Søk i DiVA

Av forfatter/redaktør
Elmer, StevenDanvind, JonasHolmberg, Hans-Christer
I samme tidsskrift
Medicine & Science in Sports & Exercise

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 107 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf