Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Residential building performance analysis at near extreme weather conditions in Hong Kong through a thermal-comfort-based strategy
Division of Building Science and Technology, College of Engineering, City University of Hong Kong, Hong Kong, China.
Division of Building Science and Technology, College of Engineering, City University of Hong Kong, Hong Kong, China.
Luleå tekniska universitet, Institutionen för samhällsbyggnad och naturresurser, Arkitektur och vatten.ORCID-id: 0000-0003-3438-1182
School of Architecture, The Chinese University of Hong Kong, Hong Kong, China.
2023 (engelsk)Inngår i: Building Simulation, ISSN 1996-3599, E-ISSN 1996-8744, Vol. 16, s. 13-25Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The precise building performance assessment of residential housings in subtropical regions is usually more difficult than that for the commercial premises due to the much more complicated behavior of the occupants with regard to the change in indoor temperature. The conventional use of a fixed schedule for window opening, clothing insulation and cooling equipment operation cannot reflect the real situation when the occupants respond to the change in thermal comfort, thus affecting the appropriateness of the assessment results. To rectify the situation, a new modeling strategy in which the modification of the various operation schedules was based on the calculated thermal comfort (TC), was developed in this study. With this new TC-based strategy, the realistic building performances under different cooling provision scenarios applied to a high-rise residential building under the near extreme weather conditions were investigated and compared. It was found that sole provision of ventilation fans could not meet the zone thermal comfort by over 68% of the time, and air-conditioning was essential. The optimal use of ventilation fans for cooling could only help reduce the total cooling energy demand by less than 12% at best which could only be realistically evaluated by adopting the present strategy. Parametric studies were conducted which revealed that some design factors could offer opportunities for reducing the total cooling energy under the near extreme weather conditions.

sted, utgiver, år, opplag, sider
Springer Nature, 2023. Vol. 16, s. 13-25
Emneord [en]
building performance simulation, predicted mean vote, residential housings, thermal comfort, ventilation potential
HSV kategori
Forskningsprogram
Arkitektur
Identifikatorer
URN: urn:nbn:se:ltu:diva-93762DOI: 10.1007/s12273-022-0934-8ISI: 000869583700002Scopus ID: 2-s2.0-85140115621OAI: oai:DiVA.org:ltu-93762DiVA, id: diva2:1707295
Merknad

Validerad;2022;Nivå 2;2022-11-30 (joosat);

Funder: Hong Kong Special Administrative Region, China (CU R4046-18F)

Tilgjengelig fra: 2022-10-31 Laget: 2022-10-31 Sist oppdatert: 2025-10-21bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Lau, Kevin Ka-Lun

Søk i DiVA

Av forfatter/redaktør
Lau, Kevin Ka-Lun
Av organisasjonen
I samme tidsskrift
Building Simulation

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 157 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf