Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Thermal Performance of Solid Interface Materialsin Immersion Cooling for Data Centers
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik.
2025 (engelsk)Independent thesis Advanced level (professional degree), 20 poäng / 30 hpOppgave
Abstract [en]

As the development of more and more powerful and transistor-dense processors continues, following the demandof cloud-based services, data storage and the proliferation of AI, coupled with the failure of Dennard scaling,the thermal output density of high-performance processors has increased significantly in latter years. Thus,the need for heat management to safeguard performance and hardware has become a pressing need; a needseemingly necessitating a move to liquid cooling from air cooling, among which, single-phase immersion coolingis among the emerging alternatives.

After an overview of the state-of-the-art on processor thermal management, the main part of the thesis isan experimental investigation of the performance of solid thermal interface materials in single-phase immersioncooling. To achieve this, tests were performed on an immersion cooling testbed using thermal test vehicles(TTVs) which mimic the thermal output of CPUs. The results showed that of the tested materials indiumfoil, pyrolytic graphite sheet and graphene composite, the thermal pads of graphene composite consistentlyperformed the best, and produced the lowest temperature.

sted, utgiver, år, opplag, sider
2025. , s. 59
Emneord [en]
Liquid cooling, Immersion cooling, single-phase immersion cooling, indium, Thermal interface materials, Thermal contact resistance, IC thermal management, Surface roughness, Contact area, Indium, graphite TIM, TTV, Flow rate testing, Inlet temperature ramping
HSV kategori
Identifikatorer
URN: urn:nbn:se:ltu:diva-114390OAI: oai:DiVA.org:ltu-114390DiVA, id: diva2:1991100
Eksternt samarbeid
RISE
Fag / kurs
Student thesis, at least 30 credits
Utdanningsprogram
Materials Engineering, master's level
Veileder
Examiner
Tilgjengelig fra: 2025-08-22 Laget: 2025-08-21 Sist oppdatert: 2025-10-21bibliografisk kontrollert

Open Access i DiVA

fulltext(29884 kB)661 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 29884 kBChecksum SHA-512
719596eca798197ee31479b9b6bc8c7a328a0b6d45f7111797dfc5e496034ea5e7319446e68b7625d0b60c6d3be3f5a5438e3c30d409c096217d02d0ba667098
Type fulltextMimetype application/pdf

Søk i DiVA

Av forfatter/redaktør
Åström, Oskar
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 662 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 380 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf