Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
An organic Rankine cycle off-design model for the search of the optimal control strategy
University of Padova, Department of Industrial Engineering.
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap.ORCID-id: 0000-0002-4532-4530
University of Padova, Department of Industrial Engineering.
ENEL Engineering and Innovation, via Andrea Pisano 120, 56126 Pisa.
2013 (Engelska)Ingår i: Energy, ISSN 0360-5442, E-ISSN 1873-6785, Vol. 58, s. 97-106Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Power generation from low enthalpy geothermal resources using Organic Rankine Cycle systems is markedly influenced by the temperature level of the heat source and heat sink. During plant operation the actual temperature of the geofluid may be different from the value assumed in the design phase. In addition, the seasonal and daily variations of the ambient temperature greatly affect the power output especially when a dry condensation system is used. This paper presents a detailed off-design model of an Organic Rankine Cycle that includes the performance curves of the main plant components. Two capacitive components in the model have the key function of damping the temporary disequilibrium of mass and energy inside the system. Isobutane and R134a are considered as working fluids, mainly operating in subcritical and supercritical cycles, respectively. The off-design model is used to find the optimal operating parameters that maximize the electricity production in response to changes of the ambient temperatures between 0 and 30 °C and geofluid temperatures between 130 and 180 °C. This optimal operation strategy can be conveniently applied both to already existing plants and to the choice of new design plant configurations.

Ort, förlag, år, upplaga, sidor
Elsevier , 2013. Vol. 58, s. 97-106
Nationell ämneskategori
Energiteknik
Forskningsämne
Energiteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-27969DOI: 10.1016/j.energy.2012.12.035ISI: 000323534900012Scopus ID: 2-s2.0-84881093073Lokalt ID: 198b3813-f0c3-486e-b127-1f7eebdecf87OAI: oai:DiVA.org:ltu-27969DiVA, id: diva2:1001161
Konferens
International Conference on Efficiency, Cost, Optimization and Simulation of Energy Conversion Systems and Processes : 26/06/2012 - 29/06/2012
Anmärkning
Validerad; 2013; 20130128 (andbra); Konferensartikel i tidskriftTillgänglig från: 2016-09-30 Skapad: 2016-09-30 Senast uppdaterad: 2025-10-03Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Toffolo, Andrea

Sök vidare i DiVA

Av författaren/redaktören
Toffolo, Andrea
Av organisationen
Energivetenskap
I samma tidskrift
Energy
Energiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 209 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf