Wet clutch transmission fluid for AWD differentials: base fluid influence on friction characteristics
Statoil Lubricants, Nynäshamn.
Haldex Traction Systems AB.
2004 (Engelska)Ingår i: Tribology and lubrication engineering: 14th International Colloquium Tribology, January 13 - 15, 2004 / [ed] Wilfried J. Bartz, Ostfildern: Techn. Akad. Esslingen , 2004, s. 399-404Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

The influence of base fluids on the anti-shudder properties of transmission fluids for wet clutches in all-wheel drive systems was studied. The all-wheel drive system, featuring a wet multi-plate clutch with a sintered brass base friction material, was described. Five different fluids (Fluid C = semi-synthetic, Fluid A and E = synthetic based fluids combined with the additive package from Fluid C, Fluid B and D = mineral based fluids combined with the additive package from fluid C) were used. Fluids A and B were low viscosity fluids while Fluids D and E were high viscosity fluid. The low viscosity base fluids presented a higher temperature dependence of the dynamic friction, μ50, compared to high viscosity fluids. These low viscosity fluids had better anti-shudder properties compared to the high viscosity fluids, especially at lower temperatures. The friction characteristics were mainly additive dependant, since large differences in the friction parameters could be observed from tests run at temperatures corresponding to a given viscosity. Synthetic and mineral base fluids showed similar behavior while the semi-synthetic commercial fluid presented better performance in some areas, implying that the additive package lose some performance when placed in a different base fluid than the originally intended. This is an abstract of a paper presented at the Technische Akademie Esslingen 14th International Colloquium Tribology (Stuttgart/Ostfildern, Germany 1/13-15/2004).

Ort, förlag, år, upplaga, sidor
Ostfildern: Techn. Akad. Esslingen , 2004. s. 399-404
Nationell ämneskategori
Annan maskinteknik
Forskningsämne
Maskinelement
Identifikatorer
URN: urn:nbn:se:ltu:diva-35770Lokalt ID: a6fdc0d0-037f-11dc-8b31-000ea68e967bISBN: 3-924813-54-X (tryckt)OAI: oai:DiVA.org:ltu-35770DiVA, id: diva2:1009024
Konferens
International Colloquium Tribology : 13/01/2004 - 15/01/2004
Anmärkning
Godkänd; 2004; 20070516 (cira)Tillgänglig från: 2016-09-30 Skapad: 2016-09-30 Senast uppdaterad: 2025-10-22Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Person

Mäki, Rikard

Sök vidare i DiVA

Av författaren/redaktören
Mäki, Rikard
Annan maskinteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetricpoäng

isbn
urn-nbn
Totalt: 73 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf