Bedömning av tre in-line fuktkvotsmätare för trä
2011 (Engelska)Självständigt arbete på avancerad nivå (yrkesexamen), 20 poäng / 30 hpStudentuppsats (Examensarbete)
Abstract [en]

The vision of wood as an engineering material and a first choice in buildings, constructions and furniture production put high demands on measuring equipment which can define and determine the quality of boards and planks. The moisture content in wood is a quality factor that is all too often badly described when sawn goods is delivered, but still it is an important factor in the further processing. This thesis is a part of a project, where the objective is to find or develop measuring equipment which can determine the moisture content between 7 to 18% MC with an accuracy of ±1 % (90 % confidence interval). Within the frames of this thesis, three moisture content meters for inline use where tested. A test material with five wood classes was produced. Each class included approximately twenty pieces. The intention with the wood classes was to find differences between the meters in how they handle different types of wood. Two of the equipments were tested in industry and the third in the lab. The meters were calibrated with the same material within the span 8 to 17,5 % MC. The test material was then fed through the meters and the values were logged. The results were analyzed in regard to the measuring technique or method the meter was using. According to the results, there are differences between the methods. The MC meter which is using the capacitance method shows too high values when measuring high density pieces compared to low density pieces with the same moisture content. This is a result of the nature of capacitance, which mostly depends on the amount of water and not the fraction between water and wood. The results also showed that the meter which used the shortest wavelength (microwaves) measured too high values in and around knots. The reason for this behavior is unclear, but could be explained by diffraction around the knot due to the higher density. In general, the MC meters showed good accuracy.

Ort, förlag, år, upplaga, sidor
2011. , s. 38
Nyckelord [en]
Technology
Nyckelord [sv]
Teknik, microwave, dielectric properties
Identifikatorer
URN: urn:nbn:se:ltu:diva-42335Lokalt ID: 05b7d17b-7796-49bd-b93f-b5bbd93856f2OAI: oai:DiVA.org:ltu-42335DiVA, id: diva2:1015555
Ämne / kurs
Examensarbete, minst 30 hp
Utbildningsprogram
Civilingenjör, Träteknik
Handledare
Examinatorer
Anmärkning
Validerat; 20110402 (anonymous)Tillgänglig från: 2016-10-04 Skapad: 2016-10-04 Senast uppdaterad: 2025-10-22Bibliografiskt granskad

Open Access i DiVA

fulltext(1570 kB)345 nedladdningar
Filinformation
Filnamn FULLTEXT02.pdfFilstorlek 1570 kBChecksumma SHA-512
667ddab148be697fdc647d06c44b24447692db682a44c5390b37ac01e56d40ec73b96185298cda4ea5c12a6c60d44aa2177452e3271b0762fd9fed2b7b42c729
Typ fulltextMimetyp application/pdf

Sök vidare i DiVA

Av författaren/redaktören
Nilsson, Martin

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 347 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 97 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf