Driftstörningar
Det förekommer återkommande driftstörningar på några av sök-portalerna på grund av hög belastning. Vi arbetar på att lösa problemet, ni kan tillfälligt mötas av ett felmeddelande.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Shear Capacity of Stud-Groove Connector in Glulam-concrete Composite Structure
Department of Civil Engineering and Mechanics, Central South University of Forestry and Technology, 498 Shaoshan Road, Changsha, Hunan, 410004, China.
Department of Civil Engineering and Mechanics, Central South University of Forestry and Technology, 498 Shaoshan Road, Changsha, Hunan, 410004, China.
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Träteknik.ORCID-id: 0000-0001-5872-2792
Division of Structural Mechanics, Lund University, Box 188, Lund, 221 00, Sweden.
Visa övriga samt affilieringar
2017 (Engelska)Ingår i: BioResources, E-ISSN 1930-2126, Vol. 12, nr 3, s. 4690-4706Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

timber-concrete composite structure (TCC) is economically and environmentally friendly. One of the key design points of this kind of structure is to ensure the reliability of the shear connectors. The objective of this paper is to study the mechanical property of stud-groove-type connectors and to provide shear capacity equations for stud-groove connectors in timber-concrete composite structures. Based on the Johansen Yield Theory (European Yield Model), some mechanical models and capacity equations for stud-groove-type connectors in timber-concrete structures were studied. Push-out specimens with different parameters (stud diameter, stud length, groove width, and groove depth) were tested to obtain the shear capacity and slip modulus. The experimental strengths were used to validate equations given in the paper. The shear capacity and slip modulus of stud-groove-type connectors was in direct proportion to the diameter of studs and the dimension of the groove. Comparison between the theoretical and the experimental shear strength results showed reasonable agreement. The highlight of this study on shear capacity equations could significantly reduce the push-out tests before investigating the other properties of TCC

Ort, förlag, år, upplaga, sidor
North Carolina State University , 2017. Vol. 12, nr 3, s. 4690-4706
Nationell ämneskategori
Annan maskinteknik
Forskningsämne
Träteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-63663DOI: 10.15376/biores.12.3.4690-4706ISI: 000408497700013Scopus ID: 2-s2.0-85026767734OAI: oai:DiVA.org:ltu-63663DiVA, id: diva2:1104717
Anmärkning

Validerad;2017;Nivå 2;2017-06-01 (andbra)

Tillgänglig från: 2017-06-01 Skapad: 2017-06-01 Senast uppdaterad: 2025-10-22Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Wang, Alice

Sök vidare i DiVA

Av författaren/redaktören
Wang, Alice
Av organisationen
Träteknik
I samma tidskrift
BioResources
Annan maskinteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 164 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf