Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Experimental studies of air-blast atomization on the CO2 capture with aqueous alkali solutions
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap. State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical and Chemical Engineering, Nanjing Tech University, Nanjing, China.
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap.ORCID-id: 0000-0002-0200-9960
State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical and Chemical Engineering, Nanjing Tech University, Nanjing, China.
State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical and Chemical Engineering, Nanjing Tech University, Nanjing, China.
2019 (Engelska)Ingår i: Chinese Journal of Chemical Engineering, ISSN 1004-9541, E-ISSN 2210-321X, Vol. 27, nr 10, s. 2390-2396Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

In this work, an air-blast atomizing column was used to study the CO2 capture performance with aqueous MEA (mono-ethanol-amine) and NaOH solutions. The effects of gas flow rate, the liquid to gas ratio (L/G), the CO2 concentration on the CO2 removal efficiency (η) and the volumetric overall mass transfer coefficient (KGav) were investigated. The air-blast atomizing column was also compared with the pressure spray tower on the studies of the CO2 capture performance. For the aqueous MEA and NaOH solutions, the experimental results show that the ηdecreases with increasing gas flow rate and CO2 concentration while it increases with increasing L/G. The effects on KGav are more complicated than those for η. When the CO2 concentration is low (3 v/v%), KGav increases with increasing gas flow rate while decreases with increasing L/G. However, when the CO2 concentration is high (9.5 v/v%), as the gas flow rate and L/G increases, KGav increases first and then decreases. The aqueous MEA solution achieves higher η and KGav than the aqueous NaOH solution. The air-blast atomizing column shows a good performance on CO2 capture.

Ort, förlag, år, upplaga, sidor
Elsevier, 2019. Vol. 27, nr 10, s. 2390-2396
Nyckelord [en]
Air-blast atomizer, CO2 capture, Aqueous alkali solutions
Nationell ämneskategori
Energiteknik
Forskningsämne
Energiteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-73068DOI: 10.1016/j.cjche.2019.01.021ISI: 000506861100016Scopus ID: 2-s2.0-85063296223OAI: oai:DiVA.org:ltu-73068DiVA, id: diva2:1292582
Anmärkning

Validerad;2020;Nivå 2;2020-01-13 (johcin)

Tillgänglig från: 2019-02-28 Skapad: 2019-02-28 Senast uppdaterad: 2025-10-22Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Li, ZhengJi, Xiaoyan

Sök vidare i DiVA

Av författaren/redaktören
Li, ZhengJi, Xiaoyan
Av organisationen
Energivetenskap
I samma tidskrift
Chinese Journal of Chemical Engineering
Energiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 143 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf