Picture frame and diagonal compression testing of cross-laminated timber
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Träteknik.ORCID-id: 0000-0002-0900-5110
Department of Manufacturing and Civil Engineering, Faculty of EngineeringNorwegian University of Science and TechnologyGjøvikNorway.
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Träteknik.ORCID-id: 0000-0002-4686-4010
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Träteknik.ORCID-id: 0000-0002-0145-080x
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: Materials and Structures, ISSN 1359-5997, E-ISSN 1871-6873, Vol. 52, nr 4, artikel-id 66Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Currently, no appropriate standard exists that describes how to determine the in-plane shear stiffness for cross-laminated timber (CLT) panels, meaning that, there is a lack of appropriate and reliable test methods. In this paper, two gross shear test methods are evaluated: a picture frame test and a diagonal compression test, which are intended to measure the shear stiffness of a whole CLT panel. This evaluation aimed to compare the shear modulus, the amount of compression/tension in the diagonal directions of the panels and the deformations of both sides of the panels. The picture frame test and diagonal compression test provides a bi- and uniaxial pre-stress, respectively. A total of 30 non-edge glued CLT panels were tested, 17 3-layer and 13 5-layer panels. The shear modulus for the 3- and 5-layer non-edge-glued panels were measured as 418 and 466 MPa, respectively, in the picture frame test. In the diagonal compression test, the shear modulus was measured to substantially higher values of 530 and 626 MPa for the 3- and 5-layer panels, respectively. In the picture frame test, panels were equally stretched along one of the diagonals as they were compressed along the other diagonal, which was not the case for panels in the diagonal compression test. The test results also showed that measuring only one side incurs a risk of over- or under-estimating the in-plane shear modulus. Compared with results from the literature, the picture frame test seems to be a more reliable test method than the diagonal compression test.

Ort, förlag, år, upplaga, sidor
Springer, 2019. Vol. 52, nr 4, artikel-id 66
Nyckelord [en]
In-plane shear stiffness, Picture frame method, CLT, Shear modulus, Diagonal compression
Nationell ämneskategori
Husbyggnad Annan maskinteknik
Forskningsämne
Träteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-74874DOI: 10.1617/s11527-019-1372-7ISI: 000472221500001Scopus ID: 2-s2.0-85067616889OAI: oai:DiVA.org:ltu-74874DiVA, id: diva2:1328805
Anmärkning

Validerad;2019;Nivå 2;2019-06-24 (svasva)

Tillgänglig från: 2019-06-23 Skapad: 2019-06-23 Senast uppdaterad: 2025-10-22Bibliografiskt granskad
Ingår i avhandling
1. In-Plane Shear Modulus of Cross-Laminated Timber
Öppna denna publikation i ny flik eller fönster >>In-Plane Shear Modulus of Cross-Laminated Timber
2021 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Cross-laminated timber (CLT) is a building component used in walls, floors, roofs, or beams in a building. The advantages of using CLT as a building component are, among others, its high load-carrying capability and the possibility of pre-fabrication. The in-plane shear properties of a CLT panel are the in-plane shear modulus and in-plane shear load carrying capacity. This thesis is solely about the in-plane shear modulus and is intended to increase the understanding about the in-plane shear modulus of CLT panels. The in-plane shear modulus is important and there is a need to better understand and estimate its value. The objective of this work was to contribute to the need of finding a suitable test method to measure the in-plane shear modulus of CLT panels and to find factors affecting the in-plane shear modulus.  Three different methods: the picture frame test, the diagonal compression test and the diaphragm shear test, were used in practice and compared to a theoretical test method, the pure shear test. The three methods were compared by conducting experimental tests and by simulating the methods using finite element (FE). Based on the FE simulations, an equation to calculate the shear modulus was created for each test method.  Results from the FE analyses showed that the picture frame test gave results similar to the theoretical pure shear test models. The reason for this result was that the picture frame test is a biaxial testing method. The diagonal compression test and the diaphragm shear test are uniaxial test method. It was also concluded that the picture frame test has a pure shear state in the measured region. The mean error for the in-plane shear modulus equations was estimated, by comparing results from practical testing and FE simulations, to be -2.5%, +12.6% and +11.8% for the picture frame test, diagonal compression test and diaphragm shear test, respectively. The diagonal compression test was the preferred method to use with respect to its simplicity.The factors having an impact on the in-plane shear modulus were found by comparing multiple FE simulations. The results showed that it is possible to increase the in-plane shear modulus by: increasing the odd numbered layers width-to-thickness ratio; decreasing the odd layers thickness ratio of the CLT panels thickness; increasing the number of layers; reducing the gaps between boards; and using alternative main laminate directions. 

Ort, förlag, år, upplaga, sidor
Luleå: Luleå University of Technology, 2021
Serie
Doctoral thesis / Luleå University of Technology, ISSN 1402-1544
Nationell ämneskategori
Annan samhällsbyggnadsteknik Husbyggnad
Forskningsämne
Träteknik
Identifikatorer
urn:nbn:se:ltu:diva-83652 (URN)978-91-7790-823-4 (ISBN)978-91-7790-824-1 (ISBN)
Disputation
2021-06-09, Auditorium A, Skellefteå, 09:00 (Engelska)
Opponent
Handledare
Tillgänglig från: 2021-04-15 Skapad: 2021-04-14 Senast uppdaterad: 2025-10-21Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Turesson, JonasBjörnfot, AndersBerg, SvenEkevad, Mats

Sök vidare i DiVA

Av författaren/redaktören
Turesson, JonasBjörnfot, AndersBerg, SvenEkevad, Mats
Av organisationen
Träteknik
I samma tidskrift
Materials and Structures
HusbyggnadAnnan maskinteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 329 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf