Driftstörningar
Det förekommer återkommande driftstörningar på några av sök-portalerna på grund av hög belastning. Vi arbetar på att lösa problemet, ni kan tillfälligt mötas av ett felmeddelande.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Poly(3,4‐ethylenedioxythiophene)‐Based Neural Interfaces for Recording and Stimulation: Fundamental Aspects and In Vivo Applications
Center for Translational Neurophysiology of Speech and Communication, Fondazione Istituto Italiano di Tecnologia, via Fossato di Mortara 17, Ferrara, 44121 Italy.ORCID-id: 0000-0002-9660-9894
Center for Translational Neurophysiology of Speech and Communication, Fondazione Istituto Italiano di Tecnologia, via Fossato di Mortara 17, Ferrara, 44121 Italy; Sezione di Fisiologia Università di Ferrara via Fossato di Mortara 17 Ferrara 44121 Italy.
Luleå tekniska universitet, Institutionen för hälsa, lärande och teknik, Omvårdnad och medicinsk teknik. Department of Microsystems Engineering‐IMTEK, University of Freiburg, Freiburg, 79110 Germany; BrainLinks‐BrainTools Center, University of Freiburg, Freiburg, 79110 Germany.ORCID-id: 0000-0001-8779-7478
Center for Translational Neurophysiology of Speech and Communication, Fondazione Istituto Italiano di Tecnologia, via Fossato di Mortara 17, Ferrara, 44121 Italy.
Visa övriga samt affilieringar
2022 (Engelska)Ingår i: Advanced Science, E-ISSN 2198-3844, Vol. 9, nr 12, artikel-id 2104701Artikel, forskningsöversikt (Refereegranskat) Published
Abstract [en]

Next‐generation neural interfaces for bidirectional communication with the central nervous system aim to achieve the intimate integration with the neural tissue with minimal neuroinflammatory response, high spatio‐temporal resolution, very high sensitivity, and readout stability. The design and manufacturing of devices for low power/low noise neural recording and safe and energy‐efficient stimulation that are, at the same time, conformable to the brain, with matched mechanical properties and biocompatibility, is a convergence area of research where neuroscientists, materials scientists, and nanotechnologists operate synergically. The biotic–abiotic neural interface, however, remains a formidable challenge that prompts for new materials platforms and innovation in device layouts. Conductive polymers (CP) are attractive materials to be interfaced with the neural tissue and to be used as sensing/stimulating electrodes because of their mixed ionic‐electronic conductivity, their low contact impedance, high charge storage capacitance, chemical versatility, and biocompatibility. This manuscript reviews the state‐of‐the‐art of poly(3,4‐ethylenedioxythiophene)‐based neural interfaces for extracellular recording and stimulation, focusing on those technological approaches that are successfully demonstrated in vivo. The aim is to highlight the most reliable and ready‐for‐clinical‐use solutions, in terms of materials technology and recording performance, other than spot major limitations and identify future trends in this field.

Ort, förlag, år, upplaga, sidor
John Wiley & Sons, 2022. Vol. 9, nr 12, artikel-id 2104701
Nyckelord [en]
drug delivery, neural recording, organic electrochemical transistors, poly(3, 4‐ethylenedioxythiophene), stimulation
Nationell ämneskategori
Neurovetenskaper
Forskningsämne
Medicinsk teknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-89466DOI: 10.1002/advs.202104701ISI: 000758567800001PubMedID: 35191224Scopus ID: 2-s2.0-85124939296OAI: oai:DiVA.org:ltu-89466DiVA, id: diva2:1643438
Forskningsfinansiär
EU, Europeiska forskningsrådet, 759655
Anmärkning

Validerad;2022;Nivå 2;2022-05-06 (hanlid);

Funder: IIT-Istituto Italiano di Tecnologia; University of Ferrara; University of Modena and Reggio Emilia;  Freiburg Institute for Advanced Studies (FRIAS); German Research Foundation (DFG, EXC 1086)

Tillgänglig från: 2022-03-09 Skapad: 2022-03-09 Senast uppdaterad: 2025-10-21Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Asplund, Maria

Sök vidare i DiVA

Av författaren/redaktören
Bianchi, MicheleAsplund, MariaStieglitz, Thomas
Av organisationen
Omvårdnad och medicinsk teknik
I samma tidskrift
Advanced Science
Neurovetenskaper

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 209 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf