Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Experimental investigation of vortex rope mitigation in a 10 MW axial turbine
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Strömningslära och experimentell mekanik.ORCID-id: 0000-0002-3349-601X
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Strömningslära och experimentell mekanik.ORCID-id: 0009-0004-2676-3839
Vattenfall AB R&D, Alvkarleby, SE 814 26, Sweden.
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Strömningslära och experimentell mekanik.ORCID-id: 0000-0001-7599-0895
2025 (Engelska)Ingår i: Renewable energy, ISSN 0960-1481, E-ISSN 1879-0682, Vol. 238, artikel-id 121920Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Increased utilization of hydraulic turbines as a regulatory tool for electrical grid stabilization forces some turbines to operate away from their design point, thus increasing wear and tear. In here, rotating vortex rope (RVR) mitigation by means of radial insertion of cylindrical rods in the draft tube is investigated experimentally on a 10 MW Kaplan turbine operating as a propeller. Pressure measurements in the draft tube, runner chamber and spiral casing, along with strain and acceleration measurements on the turbine shaft are performed to scrutinize the effectiveness of the mitigation system. Three part-load operating points are investigated, corresponding to 83%, 72%, and 68% of the guide vane servo stroke relative to the best-efficiency point opening. It is shown that the mitigation system dampens the harmful effects of the vortex rope at all operating points, especially at lower part-load conditions. Specifically, the pressure amplitude of the RVR fundamental mode inside the runner chamber reduces by 84%, 63%, and 73% at the three investigated operating points, relative to the amplitudes without mitigation. On the turbine shaft, the fundamental mode of the axial thrust oscillations at the RVR frequency reduces by 65%, 83%, and 95%. It is shown that the mitigation does not come with a high cost on the turbine time-averaged efficiency over the course of the measurements, the penalty being 2%, 2.5%, and 3.2% at the protrusion length where optimal mitigation is achieved at each operating point. For high-head machines, the penalty is expected to be lower since the relative importance of the draft tube diminishes for higher heads.

Ort, förlag, år, upplaga, sidor
Elsevier, 2025. Vol. 238, artikel-id 121920
Nyckelord [en]
Hydropower, Off-design operation, Rotating vortex rope, Turbine efficiency, Vortex rope mitigation
Nationell ämneskategori
Strömningsmekanik Energiteknik
Forskningsämne
Strömningslära
Identifikatorer
URN: urn:nbn:se:ltu:diva-110999DOI: 10.1016/j.renene.2024.121920ISI: 001371325200001Scopus ID: 2-s2.0-85210290672OAI: oai:DiVA.org:ltu-110999DiVA, id: diva2:1919325
Forskningsfinansiär
EU, Horisont 2020, 814958
Anmärkning

Validerad;2024;Nivå 2;2024-12-09 (signyg);

Fulltext license: CC BY

This article has previously appeared as a manuscript in a thesis.

Tillgänglig från: 2024-12-09 Skapad: 2024-12-09 Senast uppdaterad: 2025-10-21Bibliografiskt granskad
Ingår i avhandling
1. Experimental Investigation and Mitigation of Part-load Pressure Pulsations in Hydro Turbines Using Solid-body Protrusion inside the Draft Tube
Öppna denna publikation i ny flik eller fönster >>Experimental Investigation and Mitigation of Part-load Pressure Pulsations in Hydro Turbines Using Solid-body Protrusion inside the Draft Tube
2024 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

The global demand for electricity generation has been increasing over the recent decades and is expected to grow steadily. Therefore, activating new energy sources to improve the present capacity of electricity production is inevitable. In addition, the reduction of greenhouse gas emissions is another growing concern that is increasingly promoted. Consequently, the integration of clean sources of energy into the electrical grid is a necessity. Renewable energy sources such as wind and solar appear as practical and easy-to-harvest solutions that are clean and sustainable. Thus, their penetration into the electrical grid is both encouraged and pursued on a global scale. However, these sources are intermittent and have a slow regulation response, and an electric network predominantly comprising such sources faces challenges in adapting to the market’s fluctuating demand. As a result, a rapid-response auxiliary source is required in such networks to balance the grid output and guarantee a stable supply of electricity. Hydropower is an ideal and clean alternative that can adopt this regulation role due to its short response time. The shift in hydropower implementation towards this new role requires a broader range of operations with more frequent transitions between the design and off-design conditions. However, current hydro turbines are designed to operate at a limited range of the highest efficiency, termed the best efficiency point (BEP). When operating away from the BEP, hydro turbines confront adverse flow-induced phenomena such as vortex breakdown that can induce pressure pulsations and periodic loadings. These oscillations can cause power swings and aggravated wear rates on turbine compartments through increased fatigue. Part-load (PL) turbine operation is a condition where the precession of a rotating vortex rope (RVR) in the turbine diffuser induces harmful oscillations. With prolonged turbine PL operations, these machines are expected to face a shortened life span and increased repair cycles. Therefore, the need for practical flow control methods to reduce the pressure pulsations under PL is growing.

The present thesis aims to introduce and investigate the concept of protrusion-based methods to mitigate PL pressure pulsations. The latter is attempted by perturbing the flow in the turbine with the radial insertion of solid bodies into the draft tube. The proposed geometries include cylindrical rods and flat plates. The impact of cylindrical rods has been examined on multiple scales of axial turbines, including a downscaled model turbine, a model turbine, and a prototype. These effects were observed with different measurement tools depending on the investigated turbine. The obtained resultspresented in this work for rod protrusion experiments include turbine operation parameters, timeresolved pressure data, strain data, flow visualization, and efficiency. As an improvement to the rod protrusion concept, the flat plates were tested on the downscaled model turbine. The results from these measurements consist of turbine operation parameters, time-resolved pressure data from the draft tube and vaneless space, and efficiency.

Investigated under different PL conditions, the rods could effectively mitigate the RVR-induced pressure pulsations at upper and lower PL conditions. The obtained mitigation rates under these conditions reached as high as 80%. In addition, this method proved effective in reducing flow induced fatigue at lower PL and even speed-no-load (SNL) conditions. However, rod protrusion entailed mixed results under the PL conditions where the RVR induced the strongest periodic oscillations. Moreover, the rods caused a maximum efficiency drop of approximately 3% of the BEP efficiency. More importantly, for all the investigated scales, under the conditions where the rods appeared effective, an optimum protrusion length was found where the most significant mitigation occurred. On the other hand, the investigation of plates on the downscaled model showed complete mitigation of the RVR-induced pressure pulsations under the entire turbine PL range, and the turbine efficiency was even improved under lower PL conditions.

The investigation of both protrusion-based methods verified the need for an adjustable mitigation technique that can adapt to variable flow conditions under different PL ranges. Protrusion-based flow control systems can be incorporated as a new degree of freedom in the existing turbines and modify their operational maps. Thus, depending on the turbine operating condition, the solid bodies can be protruded at a given length or retracted completely to reduce the flow-induced adverse effects with marginal efficiency penalties. Hence, the turbine can operate at an extended range with fewer consequences, which will be a key requirement for hydropower in the future.

Ort, förlag, år, upplaga, sidor
Luleå: Luleå University of Technology, 2024
Serie
Doctoral thesis / Luleå University of Technology, ISSN 1402-1544
Nationell ämneskategori
Strömningsmekanik
Forskningsämne
Strömningslära
Identifikatorer
urn:nbn:se:ltu:diva-105417 (URN)978-91-8048-572-2 (ISBN)978-91-8048-573-9 (ISBN)
Disputation
2024-06-18, E632, Luleå University of Technology, Luleå, 09:00 (Engelska)
Opponent
Handledare
Tillgänglig från: 2024-05-08 Skapad: 2024-05-08 Senast uppdaterad: 2025-10-21Bibliografiskt granskad

Open Access i DiVA

fulltext(3052 kB)135 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 3052 kBChecksumma SHA-512
dc2087d1a0c04ba9b463b579bb5854a62c82aa5599b20924f342002a8f66eeafe1d70bab5aa07bf4936105842231633096b355f126821342885cce352fca154e
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextScopus

Person

Sundström, L.R. JoelShiraghaee, ShahabCervantes, Michel J.

Sök vidare i DiVA

Av författaren/redaktören
Sundström, L.R. JoelShiraghaee, ShahabCervantes, Michel J.
Av organisationen
Strömningslära och experimentell mekanik
I samma tidskrift
Renewable energy
StrömningsmekanikEnergiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 135 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 368 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf