Driftstörningar
Det förekommer återkommande driftstörningar på några av sök-portalerna på grund av hög belastning. Vi arbetar på att lösa problemet, ni kan tillfälligt mötas av ett felmeddelande.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Bioclimatic Architectural Intervention on the Traditional Roof Design to Improve Building Thermal Performance
Civil Infrastructure Engineering and Architectural Design, Department of Civil and Planning, Vocational School, Diponegoro University, Semarang, 50275, Indonesia.
Civil Infrastructure Engineering and Architectural Design, Department of Civil and Planning, Vocational School, Diponegoro University, Semarang, 50275, Indonesia.
Civil Infrastructure Engineering and Architectural Design, Department of Civil and Planning, Vocational School, Diponegoro University, Semarang, 50275, Indonesia.
Faculty of Integrated Technologies, Universiti Brunei Darusssalam, Jalan Tungku Link, Gadong BE1410, Brunei Darussalam.
Visa övriga samt affilieringar
2025 (Engelska)Ingår i: Alam Cipta, ISSN 1823-7231, Vol. 18, nr 3, s. 89-101Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Bioclimatic architecture is currently gaining interest among architect and building designers. In response to this trend, a study using bioclimatic design was conducted in Universitas Diponegoro (UNDIP) Mosque. Modeling simulation using Autodesk Ecotect was carried out to simulate the alternative design of joglo roof. Field measurement were done to validate the difference on the thermal performance between the existing and reccomendation design. Result from field measurement showed the highest room temperature was obtained on the second floor area of the mosque by 28°C. Meanwhile according to the simulation, the bioclimatic roof could decrease the indoor temperature of the mosque around 4.3°C - 5.2°C or to the level of 24.5°C. Moreover, compared to the existing design, the bioclimatic design had higher temperature difference with outdoor temperature by 7.5°C. It means, if an air conditioning system is installed inside the mosque with bioclimatic roof, it would require a lower energy consumption. Thus, the application of bioclimatic roof on the UNDIP Mosque can be a prospective solution to improve its indoor thermal comfort and provide an environmentally friendly design. 

Ort, förlag, år, upplaga, sidor
Universiti Putra Malaysia Press , 2025. Vol. 18, nr 3, s. 89-101
Nyckelord [en]
Autodesk Ecotect, Bioclimatic design, Building thermal performance, Field measurement, Modelling and simulation
Nationell ämneskategori
Husbyggnad Energisystem
Forskningsämne
Reglerteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-116117DOI: 10.47836/AC.18.3.PAPER07Scopus ID: 2-s2.0-105024968592OAI: oai:DiVA.org:ltu-116117DiVA, id: diva2:2031317
Tillgänglig från: 2026-01-22 Skapad: 2026-01-22 Senast uppdaterad: 2026-01-22

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopusWebpage hostpublication

Person

Laila, Dina Shona

Sök vidare i DiVA

Av författaren/redaktören
Laila, Dina Shona
Av organisationen
Signaler och system
HusbyggnadEnergisystem

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 63 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf