Lifetime CostEffectiveness of Constructed Wetland and Rain Garden Facilities in Relation to Expected  Treatment Performance
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering.
2023 (English)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

The purpose of this thesis is to investigate the cost effectiveness of two different stormwater control measure (SCM) facilities, namely a constructed wetland in Boden and a rain garden in Gothenburg (both Sweden), in relation to treatment efficiency and contributing catchment area. The study approach involved collection of data, construction, and maintenance activities with their respective costs, for the two stormwater control measures from commercial and literature data. In terms of costs, the construction costs of constructed wetland facility were provided but lacked for the rain garden facility. StromTac was utilized to model the pollutant load removal values for each facility. The pollutants focused on in this study are phosphorus (P), nitrogen (N) and total suspended solids (TSS). Using the total costs and expected pollutant load removal values, the cost-effectiveness of each facility was normalized and estimated for pollutant removal efficiency and stormwater volume. The cost-effectiveness focused on the stormwater volume introduced from the catchment area to the facility and on the pollutant load removal of the three pollutants. The findings highlighted that the rain garden facility has lower total costs value than constructed wetland, namely 1 680 000 Swedish kronor and 2 180 000 Swedish kronor for respective facilities. The rain garden facility has a lower area than constructed wetland facility.  The cost-effectiveness in terms of volume treated by the facility for 1 m3 of annual stormwater throughout facility’s lifetime is in favor for constructed wetland facility where constructed wetland facility has a value of 16 kronor, m3 while rain garden has 18 kronor, m3. The cost-effectiveness in pollutant removal for each facility shows that rain garden facility has a better value for two out three pollutants namely nitrogen and total suspended solids. The reduction efficiency values generated by StormTac shows that the constructed wetland facility has better reduction efficiency value than the rain garden facility in phosphorus, worse in nitrogen and equal for total suspended solids. A major factor that could contribute to the higher phosphorus reduction efficiency of constructed wetland in comparison to rain garden facility could depend on the fact that constructed wetland facility has a serial combination of different stormwater facilities. The following order of stormwater facilities is as follows: sedimentation pond, buffer strip and wetland. Further research could be conducted using actual construction costs and long term documented maintenance costs for both facilities to make the study more robust and accurate. 

Place, publisher, year, edition, pages
2023. , p. 49
Keywords [en]
Stormwater, Total cost, StormTac, Cost-effectiveness
National Category
Environmental Engineering
Identifiers
URN: urn:nbn:se:ltu:diva-95843OAI: oai:DiVA.org:ltu-95843DiVA, id: diva2:1742793
External cooperation
SWECO
Educational program
Natural Resources Engineering, master's
Supervisors
Examiners
Available from: 2023-03-13 Created: 2023-03-11 Last updated: 2025-10-21Bibliographically approved

Open Access in DiVA

fulltext(1057 kB)485 downloads
File information
File name FULLTEXT01.pdfFile size 1057 kBChecksum SHA-512
9aa8169a14606cb1921da73458c14f912b808e1b71c5b12060c8ac89faf85a5df3683f202a5f6440ffaebe29b4c6e1f8287a49bafe98370e6c2bcd11bc936a8c
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Noorhussin Ali, Abdullah
By organisation
Department of Civil, Environmental and Natural Resources Engineering
Environmental Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 487 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1295 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf