Investigating the Potential and Limitations of Cell Spacing Adjustment for Optimized Air-Based Battery Thermal Management Systems
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Fluid and Experimental Mechanics.ORCID iD: 0000-0001-9779-7447
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Fluid and Experimental Mechanics.ORCID iD: 0000-0001-8235-9639
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Fluid and Experimental Mechanics.ORCID iD: 0000-0002-1033-0244
2024 (English)In: Energy Transitions toward Carbon Neutrality: Part VI, Scanditale , 2024Conference paper, Published paper (Refereed)
Abstract [en]

A reliable battery thermal management system plays a crucial role in the safe, efficient, and long-term operation of a high-performance lithium battery system. This study evaluates the temperature rise, pressure drop, capacity loss, and cyclical cost of an air-cooled battery system consisting of 90 cylindrical battery cells placed ina staggered arrangement in the module. The effect of spacing between the adjacent cells and inflow velocity is investigated for the battery system operating at high charge/discharge rates of 3C and 5C. The results demonstrate that the hybrid model, which consists of the battery life model integrated with the simplified modeling approach for the thermal evaluation of battery packs, provides a cost-effective tool for multi-objective analysis and optimization of air-cooled battery packages.The results reveal that the air-based cooling system has the potential to fulfill the safety standards in all studied cases, and employing battery modules with larger cell spacing at a constant inflow velocity may reduce the maximum temperature, pressure drop, and cyclical cost by up to 2.14%, 93.36%, and 35.69%, respectively, while extending the lifespan of the battery system by up to 55.45%. However, it is found that the air-based cooling system approaches its limit of thermal performance at high inflow velocities. A novel index (MCR index) is proposed in this paper to characterize the limitationsassociated with adjusting cell spacing for air-based battery cooling systems. It is observed that for systems with an MCR index beyond 600, the effect of cell spacingon thermal performance becomes negligible. This can be used as a useful guideline for optimizing air-based battery thermal management systems or integratingthem with other cooling methods.

Place, publisher, year, edition, pages
Scanditale , 2024.
Series
Energy Proceedings, ISSN 2004-2965 ; 43
Keywords [en]
battery thermal management system, cylindrical lithium battery, air-cooled system, spacing effect, simplified modeling approach, cyclical cost
National Category
Energy Engineering
Research subject
Fluid Mechanics
Identifiers
URN: urn:nbn:se:ltu:diva-105141DOI: 10.46855/energy-proceedings-11036Scopus ID: 2-s2.0-85190869646OAI: oai:DiVA.org:ltu-105141DiVA, id: diva2:1852257
Conference
15th International Conference on Applied Energy (ICAE 2023), Doha, Qatar, December 3-7, 2023
Note

Funder: StandUp for Energy; Green Transition North;

Full text license: CC BY 4.0;

Available from: 2024-04-17 Created: 2024-04-17 Last updated: 2025-10-21Bibliographically approved
In thesis
1. Heat transfer in ordered porous media with application to batteries
Open this publication in new window or tab >>Heat transfer in ordered porous media with application to batteries
2024 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

In recent decades, promising technological advancements in clean energy production and green transportation, driven by the depletion of oil resources, energy security issues, environmental challenges, and associated health concerns, have moved the world closer to a sustainable energy outlook. However, this approach has led to a high reliance on electricity and the need for optimized electricity storage systems. Among different options, lithium battery systems have gained considerable attention, particularly for electric vehicles, owing to their superior properties, such as high energy density, fast charging capacity, and long lifespan, making them compatible with both stationary and mobile applications. Nevertheless, the safe and long-term operation of lithium battery systems depends on their working temperature, as the aging process of batteries accelerates with the temperature rise, and at critical temperatures, the exothermic reactions within battery cells might lead to thermal runaway and explosion. This necessitates employing a suitable strategy to regulate the temperature within lithium batteries, which could be quite challenging due to design restrictions related to geometry, coolant selection, cost, weight, and battery system size, especially at fast charging/discharging rates. Hence, it is essential to initially have a thorough understanding of how the system operates under different working conditions and then employ an effective strategy to improve its performance. 

In this framework, the present thesis first investigates the thermal behavior of a single cylindrical battery cell with varying geometrical parameters for the jelly roll. The study is based on a mathematical model predicting the temperature field within the cell to identify design considerations at the cell level to minimize thermal issues for the battery thermal management system. The best balance between thermal concerns and capacity was found for 21700 cylindrical cells, wherein the optimum thicknesses for the positive active material, the negative active material, the positive current collector, and the negative current collector were 180, 34, 21, and 20 μm, respectively. The thesis then shifts focus to the module-level study, evaluating the performance of air-based battery thermal management systems that meet many design criteria for battery applications but present challenges due to the low thermal conductivity of air as a coolant medium. The thermofluid characteristics of the air-based cooling system under discussion were investigated using computational fluid dynamics (CFD) simulations and compared to free cross-flow heat exchangers. The study suggests the  k-kl-ω transition model as a computationally efficient and fairly accurate turbulence model for such heat exchangers. Moreover, it was determined that under certain conditions, two-dimensional models of free cross-flow heat exchangers could replace computationally demanding three-dimensional models for wall-bounded cross-flow heat exchangers intended for battery cooling. These findings serve as a basis for developing a novel approach for modeling the performance of large air-cooled battery systems, termed the simplified modeling approach.

The simplified modeling approach consists of three sub-models, including a CFD model to simulate heat and flow characteristics around a cell in a periodic flow region, a set of approximate equations to determine the heat transfer rate for each row along the battery module, and an analytical model to predict the temperature field within individual cells. The employment of these sub-models, along with their independent functioning, significantly reduces computing costs. This model was employed to investigate cell spacing within an air-cooled battery module. At a constant mass flow rate to the system, the study suggests that maintaining transverse and longitudinal center-to-center distances of 1.7D and 0.9D between the cells, respectively, results in a fair balance between the maximum temperature rise and temperature gradient within the module. Following this, the model was combined with an empirical capacity degradation model to study how cell spacing and cooling conditions affect the number of cycles a battery module can operate. According to the study, proper cell spacing may extend the lifetime of the battery module by up to 55%. However, this life cycle extension comes at the cost of greater power consumption, which significantly raises cyclical costs, especially in densely packed battery modules. To address this issue, splitter plates were integrated into the design of densely packed battery modules. It was observed that splitter plates with lengths comparable to wake size could mitigate the maximum temperature rise and capacity degradation process within the batteries without causing extra cyclical costs. 

Place, publisher, year, edition, pages
Luleå: Luleå University of Technology, 2024
Series
Doctoral thesis / Luleå University of Technology 1 jan 1997 → …, ISSN 1402-1544
Keywords
battery thermal management system, cylindrical battery, heat transfer, simplified modeling approach, CFD, analytical model, jelly roll, cell spacing, splitter plate, lifespan
National Category
Fluid Mechanics
Research subject
Fluid Mechanics
Identifiers
urn:nbn:se:ltu:diva-107346 (URN)978-91-8048-602-6 (ISBN)978-91-8048-603-3 (ISBN)
Public defence
2024-09-27, A109, Luleå University of Technology, Luleå, 13:00 (English)
Opponent
Supervisors
Available from: 2024-06-13 Created: 2024-06-13 Last updated: 2025-10-21Bibliographically approved

Open Access in DiVA

fulltext(781 kB)151 downloads
File information
File name FULLTEXT01.pdfFile size 781 kBChecksum SHA-512
dc7cfd548e965bed06a33204681c76995e64301a6672db85202b2b7336cabf0c95382c7cc9a74438b0f95a1a8ba20a826994dfcf575332431a53c7c5c0fb9670
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Authority records

Moosavi, AminLjung, Anna-LenaLundström, Staffan

Search in DiVA

By author/editor
Moosavi, AminLjung, Anna-LenaLundström, Staffan
By organisation
Fluid and Experimental Mechanics
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 152 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 598 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf