Planned maintenance
A system upgrade is planned for 17/11-2026, at 12:00-13:00. During this time DiVA will be unavailable.
34567896 of 20
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Preclinical Evaluation of Polymer-Based Bearing Systems for Total Hip Replacemen: Physiologically Relevant Loading, Wear Particle Characterisation, and Additively Manufactured PEEK Materials
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Machine Elements.ORCID iD: 0009-0006-2194-5021
2026 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Background: Total hip replacement is one of the most successful orthopaedic interventions; however, wear remains a key factor influencing long-term implant performance and survivorship. Additively manufactured (AM) PEEK materials have emerged as potential candidates for orthopaedic bearing applications, although their tribological and biological performance under clinically representative conditions remains insufficiently understood.

Aim: The aim of this thesis was to evaluate the tribological and biological performance of AM PEEK materials for orthopaedic bearing applications, focusing on the influence of manufacturing, surface finishing, composite reinforcement, wear particle isolation and characterisation. In parallel, the thesis investigated the influence of physiologically representative loading profiles on wear behaviour in conventional metal-on-polymer systems to assess limitations in current preclinical testing approaches.

Methods: This thesis combined a systematic review with experimental evaluation of AM PEEK materials and conventional orthopaedic bearing systems.Physiologically representative loading profiles were applied to conventional metal-on-polymer hip systems using full-scale hip simulator testing to investigate their influence on preclinical wear assessment. The increased wear observed under adverse loading conditions informed subsequent investigations of AM PEEK using multidirectional pin-on-disc articulation testing at elevated contact pressures. These investigations assessed surface topography, wear behaviour and wear particle generation. A vacuum oven stabilisation approach was developed to improve gravimetric assessment of AM PEEK by reducing influence of manufacturing induced porosity on fluid absorption and mass stability. Wear particles were isolated using a phenol-based separation method designed to retain both polyethylene and PEEK particles despite similarities in material and protein density, before characterisation using scanning electron microscopy and in-vitro biological assays.

Key findings: Surface integrity was identified as a critical determinant of tribological performance in AM PEEK, with manufacturing induced porosity and surface condition exerting greater influence than surface roughness alone. A vacuum oven stabilisation approach enabled improved gravimetric assessment of AM PEEK by reducing variability associated with fluid uptake and release.A phenol-based isolation method enabled recovery and characterisation of both polyethylene and PEEK wear particles for biological evaluation. AM PEEK demonstrated biological responses comparable to conventional materials, although composite reinforcement did not improve wear or biological performance.Finally, physiologically representative loading increased wear in conventional metal-on-polymer systems relative to standardised conditions, highlighting the importance of clinically representative preclinical evaluation to reduce the risk of underestimating in-vivo wear.

Interpretation: Collectively, the findings indicate that tribological performance of additively manufactured PEEK is governed more strongly by manufacturing and finish-induced surface integrity than by surface roughness alone. Physiologically representative loading and multidirectional articulation substantially influenced wear behaviour, highlighting limitations of simplified preclinical testing approaches and reinforcing the importance of clinically relevant evaluation frameworks. Furthermore, while AM PEEK demonstrated biological responses comparable to conventional materials, improvements in tribological performance remain important for supporting further biological validation and development of orthopaedic bearing systems.

Conclusions: This thesis demonstrates the importance of clinically relevant tribological evaluation for assessing emerging orthopaedic bearing materials. Physiologically representative loading altered wear behaviour in conventional metal-on-polymer systems, while multidirectional articulation provided greater insight into the tribological performance of AM PEEK materials.While AM PEEK demonstrated biological responses comparable to conventional materials, tribological performance remained strongly dependent on manufacturing and finish-induced surface integrity and was not improved through the introduction of composite reinforcement.Overall, the findings support continued investigation of AM PEEK as a candidate orthopaedic bearing material, while highlighting the need for further optimisation of manufacturing processes and more clinically representative evaluation methodologies prior to translation.

Place, publisher, year, edition, pages
Luleå: Luleå University of Technology, 2026.
Series
Doctoral thesis / Luleå University of Technology, ISSN 1402-1544
Keywords [en]
Total hip replacement, Orthopaedic tribology, Polyetheretherketone (PEEK), Additive manufacturing, Wear, Wear particles, Multidirectional articulation, Physiological loading, Surface integrity, Biological response
National Category
Bio Materials Composite Science and Engineering Other Mechanical Engineering Manufacturing, Surface and Joining Technology
Research subject
Machine Elements
Identifiers
URN: urn:nbn:se:ltu:diva-120057ISBN: 978-91-8142-167-5 (print)ISBN: 978-91-8142-168-2 (electronic)OAI: oai:DiVA.org:ltu-120057DiVA, id: diva2:2108199
Public defence
2026-12-01, E231, Luleå University of Technology, Luleå, 09:00 (English)
Opponent
Supervisors
Available from: 2026-10-08 Created: 2026-10-06 Last updated: 2026-11-13Bibliographically approved
List of papers
1. Tribo-Mechanical Properties and Bioactivity of Additively Manufactured PAEK Materials for Load Bearing Medical Applications: A Systematic Review
Open this publication in new window or tab >>Tribo-Mechanical Properties and Bioactivity of Additively Manufactured PAEK Materials for Load Bearing Medical Applications: A Systematic Review
2023 (English)In: Biotribology, ISSN 2352-5738, Vol. 35-36, article id 100263Article, review/survey (Refereed) Published
Abstract [en]

Additive manufacturing (AM) holds significant potential in transforming medical applications, with a particular focus on polyetheretherketone (PEEK) and its derivatives, collectively known as poly-aryl-ether-ketone (PAEK) materials. Advances in AM precision have paved the way for the successful 3D printing of high-performance thermoplastics like PEEK, offering new prospects in load-bearing medical applications. This systematic review comprehensively assesses recent scientific literature concerning the tribo-mechanical properties and bioactivity of additively manufactured PAEK materials, with a specific emphasis on PEEK, for load-bearing medical uses. Despite substantial research into AM of metallic biomaterials, knowledge gaps persist regarding AM processing parameters, structure-property relationships, biological behaviours, and implantation suitability of PAEKs. This review bridges these gaps by analysing existing literature on the tribo-mechanical properties and bioactivity of additively manufactured PAEK materials, providing valuable insights into their performance in load-bearing medical applications. Key aspects explored include printing conditions, strength limitations, and outcomes of in-vitro and in-vivo evaluations. Through this systematic review, we consolidate current knowledge, delivering essential information for researchers, clinicians, and manufacturers involved in advancing additively manufactured PAEK materials for load-bearing medical applications.

Place, publisher, year, edition, pages
Elsevier, 2023
Keywords
PEEK, 3D printing, Additive manufacturing, Tribology, Medical, Bioactivity
National Category
Other Mechanical Engineering
Research subject
Machine Elements
Identifiers
urn:nbn:se:ltu:diva-102650 (URN)10.1016/j.biotri.2023.100263 (DOI)2-s2.0-85176310844 (Scopus ID)
Funder
EU, Horizon 2020, 956004
Note

Validerad;2023;Nivå 1;2023-11-22 (joosat);

CC BY-NC-ND 4.0 License

Available from: 2023-11-22 Created: 2023-11-22 Last updated: 2026-10-12Bibliographically approved
2. Effects of Physiological Loading from Patient-Derived Activities of Daily Living on the Wear of Metal-on-Polymer Total Hip Replacements
Open this publication in new window or tab >>Effects of Physiological Loading from Patient-Derived Activities of Daily Living on the Wear of Metal-on-Polymer Total Hip Replacements
Show others...
2025 (English)In: Bioengineering, E-ISSN 2306-5354, Vol. 12, no 6, article id 663Article in journal (Refereed) Published
Abstract [en]

The current pre-clinical testing standards for total hip replacements (THRs), ISO standards, use simplified loading waveforms that do not fully replicate real-world biomechanics. These standards provide a benchmark of data that may not accurately predict in vivo wear, necessitating the evaluation of physiologically relevant loading conditions. Previous studies have incorporated activities of daily living (ADLs) such as walking, jogging and stair negotiation into wear simulations. However, these studies primarily used simplified adaptations that increased axial forces and applied accelerated sinusoidal waveforms, rather than fully replicating the complex kinematics experienced by THR patients. To address this gap, this study applied patient-derived ADL profiles—jogging and stair negotiation—using a three-station hip simulator, obtained through 3D motion analysis of total hip arthroplasty patients, processed via a musculoskeletal multibody modelling approach to derive realistic hip contact forces (HCFs). The results indicate that jogging significantly increased wear rates compared to the ISO walking gait waveform, with wear increasing from 15.24 ± 0.55 to 28.68 ± 0.87 mm3/Mc. Additionally, wear was highly sensitive to changes in lubricant protein concentration, with an increase from 17 g/L to 30 g/L reducing wear by over 60%. Contrary to predictive models, stair descent resulted in higher volumetric wear (8.62 ± 0.43 mm3/0.5 Mc) compared to stair ascent (4.15 ± 0.31 mm3/0.5 Mc), despite both profiles having similar peak torques. These findings underscore the limitations of current ISO standards in replicating physiologically relevant wear patterns. The application of patient-specific loading profiles highlights the need to integrate ADLs into pre-clinical testing protocols, ensuring a more accurate assessment of implant performance and longevity.

Place, publisher, year, edition, pages
Multidisciplinary Digital Publishing Institute (MDPI), 2025
Keywords
total hip replacement, activities of daily living, physiological loading, joint simulator testing
National Category
Mechanical Engineering Materials Engineering
Research subject
Machine Elements
Identifiers
urn:nbn:se:ltu:diva-114024 (URN)10.3390/bioengineering12060663 (DOI)001516229200001 ()2-s2.0-105009148958 (Scopus ID)
Funder
EU, Horizon 2020, 956004
Note

Validerad;2025;Nivå 2;2025-07-08 (u2);

Full text: CC BY license;

Available from: 2025-07-08 Created: 2025-07-08 Last updated: 2026-10-12Bibliographically approved
3. Surface finish governs HXLPE wear and particle generation in conventional and 3D-printed PEEK hip bearings
Open this publication in new window or tab >>Surface finish governs HXLPE wear and particle generation in conventional and 3D-printed PEEK hip bearings
(English)Manuscript (preprint) (Other academic)
National Category
Other Mechanical Engineering Manufacturing, Surface and Joining Technology
Research subject
Machine Elements
Identifiers
urn:nbn:se:ltu:diva-120054 (URN)
Available from: 2026-10-06 Created: 2026-10-06 Last updated: 2026-10-06Bibliographically approved
4. Biological response to wear particles from additively manufactured PEEK and PEKK generated under multidirectional pin on disc articulation
Open this publication in new window or tab >>Biological response to wear particles from additively manufactured PEEK and PEKK generated under multidirectional pin on disc articulation
Show others...
(English)Manuscript (preprint) (Other academic)
National Category
Composite Science and Engineering
Research subject
Machine Elements; Experimental Mechanics
Identifiers
urn:nbn:se:ltu:diva-120055 (URN)
Available from: 2026-10-06 Created: 2026-10-06 Last updated: 2026-10-06Bibliographically approved
5. Tribological Performance of Additively Manufactured PEEK Composites undermultidirectional articulation relevant to orthopaedic bearings
Open this publication in new window or tab >>Tribological Performance of Additively Manufactured PEEK Composites undermultidirectional articulation relevant to orthopaedic bearings
(English)Manuscript (preprint) (Other academic)
National Category
Other Mechanical Engineering
Research subject
Machine Elements
Identifiers
urn:nbn:se:ltu:diva-120056 (URN)
Available from: 2026-10-06 Created: 2026-10-06 Last updated: 2026-10-06Bibliographically approved

Open Access in DiVA

fulltext(29528 kB)16 downloads
File information
File name FULLTEXT01.pdfFile size 29528 kBChecksum SHA-512
9a69b4de900f4ae400d87be32a3fc466d8e832bf2f642ccd980e5500db9a2cbda5d5e6179b0db95c915c894700d947a81573318b55a24024122719410e84502e
Type fulltextMimetype application/pdf
The full text will be freely available from 2027-03-10 12:00
Available from 2027-03-10 12:00

Authority records

Clegg, Benjamin A.

Search in DiVA

By author/editor
Clegg, Benjamin A.
By organisation
Machine Elements
Bio MaterialsComposite Science and EngineeringOther Mechanical EngineeringManufacturing, Surface and Joining Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 16 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 2212 hits
34567896 of 20
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf