The hydrogen economy is growing and as such also the quantities of hydrogen gas produced, transported and stored. The increased quantities make large accident scenarios in hydrogen infrastructure possible, e.g. hydrogen gas explosions. A key question is to what extent the surrounding built environment can withstand this. Blast wall design is part of answering that question. Large scale numerical simulations can be used to design blast walls, but it can require utilisation of coupled CFD (Computational Fluid Dynamics) and FEA (Finite Element Analysis) to obtain an optimised design. In utilisation of one-way coupling methodologies, it is found in the literature that the mapping resolution is seldomly reported to be systematically analyzed. Adequate mapping resolution when using a one-way coupling methodology for hydrogen gas detonation blast effects has therefore been investigated in this study. A mapping resolution of 0.25 m was sufficient to accurately capture the initial peak deflection of the blast wall of the replicated experiment. The results were also validated against an experiment and benchmarked against other studies that have used the same experiment for validation.Results showed that a one-way coupling method with a systematically chosen mapping resolution gave better or similar results than previous studies in terms of shockwave arrival time and peak deflections at the blast wall. The results demonstrate that a systematically selected mapping resolution enables accurate one-way CFD–FEA predictions of hydrogen detonation blast effects, supporting blast wall design without the need for more computationally demanding two-way coupling approaches.
Funder: EU Just Transition Fund;
Fulltext license: CC BY