On the uncertainty of building acoustic measurements: Case study of a cross-laminated timber construction
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Operation, Maintenance and Acoustics.ORCID iD: 0000-0002-8386-2292
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Operation, Maintenance and Acoustics.ORCID iD: 0000-0002-8451-4804
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Operation, Maintenance and Acoustics.ORCID iD: 0000-0001-5435-2069
2012 (English)In: Applied Acoustics, ISSN 0003-682X, E-ISSN 1872-910X, Vol. 73, no 9, p. 904-912Article in journal (Refereed) Published
Abstract [en]

If variations and uncertainty in building acoustic measurements can be controlled, construction costs can potentially be reduced since the building will not have to be acoustically over-designed. Field measurements of impact and airborne sound insulation were carried out for an industrially prefabricated cross-laminated timber (CLT) system of plate elements. The results from 18 rooms, forming three groups with respect to size, were compared to a similar study dealing with a prefabricated Volume Based Building (VBB) system. Large variations were found at frequencies below 100 Hz which is crucial for the low frequency adaptation terms connected to the weighted sound insulation indices. The measurement uncertainty was investigated by analysing the repeatability, measurement direction and the time dependence of the sound source. The variations due to the measurement procedure were found to be small compared to the total variations. It was also indicated that the variations in sound insulation are smaller with a prefabricated system compared to on-site production, since less work is required at the building site

Place, publisher, year, edition, pages
Elsevier , 2012. Vol. 73, no 9, p. 904-912
National Category
Fluid Mechanics
Research subject
Engineering Acoustics
Identifiers
URN: urn:nbn:se:ltu:diva-14769DOI: 10.1016/j.apacoust.2012.03.012ISI: 000305673300007Scopus ID: 2-s2.0-84861639993Local ID: e30fdd61-692b-4f18-9db8-9dcaba2ca212OAI: oai:DiVA.org:ltu-14769DiVA, id: diva2:987742
Note
Validerad; 2012; 20120418 (andbra)Available from: 2016-09-29 Created: 2016-09-29 Last updated: 2025-10-21Bibliographically approved
In thesis
1. Measurement and perception of sound insulation from 20 Hz between dwellings
Open this publication in new window or tab >>Measurement and perception of sound insulation from 20 Hz between dwellings
2017 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Population growth and urbanization are projected by the United Nations to add 2,5 billionpeople to the world’s urban population by 2050. We need to construct buildings in anunprecedented scale to meet global housing demand. Sustainable development is critical.Compared to traditional heavy constructions, lightweight wooden constructions are moreenvironmentally friendly and will play a key role in meeting future demands. However, thereare two major problems with lightweight constructions that need to be addressed: 1) Limitedlow frequency sound insulation and 2) Variations in sound insulation.Annoyance from walking sound tend to be higher in lightweight than in heavy constructionseven with the same measured sound insulation. The Swedish research program AkuLiteindicated that the correlation between measured sound insulation and annoyance wassignificantly improved by extending current evaluation methods from 50 Hz down to 20 Hz.Secondly, large variations in sound insulation between nominally identical lightweightconstructions are common, which leads to larger safety margins. By identifying and quantifyingunderlying causes, production costs can be minimized and the performance can be improved.The aim of the thesis is to develop a new evaluation method for impact sound insulation thatbetter correspond to rated annoyance, and to identify and control underlying causes forvariations in sound insulation. The thesis contains six papers.In Paper I and II, sound insulation measurements were carried out in a large number ofnominally identical rooms of two different industrially prefabricated lightweight woodenconstructions. The purpose was to assess and quantify the variations in impact and airbornesound insulation. In Paper I, 30 nominally identical apartments of a volume based system wasevaluated. The apartments on the highest floor achieved significantly better sound insulationdue to the extra weight on lower floors affecting the elastic connections between stories. InPaper II, 18 rooms of a cross-laminated timber system of plate elements were evaluated.Additionally, several potential parameters related to measurement uncertainty wereinvestigated.Paper III deals with measurement uncertainty. An empirical study of reverberation timemeasurements showed that current methods need to be improved, if sound insulationrequirements are to be extended to 20 Hz.Paper IV and V verified that the frequency range 20-50 Hz is important for walking soundannoyance, and that alternative frequency adaptation terms can improve the correlation betweenmeasured impact sound insulation and annoyance ratings. In Paper IV, the methodology was toperform extensive field measurements in apartment buildings of various construction types andto perform questionnaire surveys among the residents. In Paper V, the methodology was toevaluate annoyance based on binaural recordings of walking sound in a two-part listening test.In Paper VI, 70 measurements in a lightweight wooden system were evaluated to quantify thetotal variations in impact and airborne sound insulation from 20 and 50 Hz, respectively. It wasconcluded that the proposed metrics of impact sound insulation were primarily determined bythe impact sound level 20-40 Hz and that the measurement methods must be evaluatedthoroughly to avoid excessive safety margins.

A new evaluation method for impact sound insulation from 25 Hz, that correspond to the ratedannoyance for both heavy and lightweight constructions is proposed. By using the proposedmethod and attending the specific causes for variations, the lightweight industry will be able todevelop improved multi-story dwellings with higher perceived acoustic quality.

Place, publisher, year, edition, pages
Luleå: Luleå tekniska universitet, 2017
Series
Doctoral thesis / Luleå University of Technology, ISSN 1402-1544
Keywords
Sound insulation, Lightweight constructions, Annoyance, Measurement uncertainty, Low frequency, Building Acoustics, Walking noise
National Category
Other Civil Engineering
Research subject
Engineering Acoustics
Identifiers
urn:nbn:se:ltu:diva-62843 (URN)978-91-7583-868-7 (ISBN)978-91-7583-869-4 (ISBN)
Public defence
2017-05-30, F531, Luleå Tekniska Universitet, 971 87 Luleå, 09:30 (English)
Opponent
Supervisors
Funder
Swedish Research Council Formas
Note

Forskningsfinansiärer:

Sven Tyréns Stiftelse

Formas

Available from: 2017-04-05 Created: 2017-04-03 Last updated: 2025-10-22Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Öqvist, RikardLjunggren, FredrikÅgren, Anders

Search in DiVA

By author/editor
Öqvist, RikardLjunggren, FredrikÅgren, Anders
By organisation
Operation, Maintenance and Acoustics
In the same journal
Applied Acoustics
Fluid Mechanics

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 294 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf