Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Design and Implementation of Low-Cost Non-Invasive Blood Pressure Measurement Device from Photoplethysmography with Signal Quality Assessment
Chittagong University of Engineering and Technology, Department of Biomedical Engineering, Chattogram 4349, Bangladesh.
Chittagong University of Engineering and Technology, Department of Biomedical Engineering, Chattogram 4349, Bangladesh.
Chittagong University of Engineering and Technology, Department of Biomedical Engineering, Chattogram 4349, Bangladesh.
Rangamati Science and Technology University, Dept. of CSE, Rangamati 4500, Bangladesh.
Show others and affiliations
2026 (English)In: Proceedings - 2026 13th International Conference on Future Internet of Things and Cloud, FiCloud 2026, Institute of Electrical and Electronics Engineers (IEEE) , 2026, p. 341-348Conference paper, Published paper (Refereed)
Abstract [en]

Cardiovascular diseases remain a leading global health concern, necessitating accurate, non-invasive blood pressure monitoring solutions. This study presents a novel photoplethysmography (PPG)-based system that integrates three key innovations: (1) a real-time signal quality assessment (SQA) model employing a one-class SVM classifier to filter unreliable PPG segments, (2) a computationally efficient two-stage neural network (1D U-Net followed by 1D MultiResUNet) for arterial blood pressure (ABP) waveform estimation, and (3) a wearable hardware platform combining a MAX30102 optical sensor and ESP32 microcontroller for portable deployment. The SQA model uses five optimized features to achieve robust motion artifact rejection. The deep learning pipeline reconstructs ABP waveforms with mean absolute errors of 4.7 mmHg (systolic) and 4.3 mmHg (diastolic), complying with the Association for the Advancement of Medical Instrumentation (AAMI) standards. Validated on 40 subjects against reference sphygmomanometer measurements, the system demonstrates 92.5% (systolic) and 95% (diastolic) classification accuracy, with subsecond latency and low-power operation. By addressing critical challenges in motion robustness, computational efficiency, and clinical validation, this work advances the practicality of cuffless BP monitoring for telehealth and resource-limited settings.

Place, publisher, year, edition, pages
Institute of Electrical and Electronics Engineers (IEEE) , 2026. p. 341-348
Series
International Conference on Future Internet of Things and Cloud (FiCloud), ISSN 2996-1017
Keywords [en]
Photoplethysmography, Arterial Blood Pressure, Deep Learning, Signal Quality Assessment, Wearable Devices
National Category
Signal Processing Other Medical Engineering
Research subject
Cyber Security
Identifiers
URN: urn:nbn:se:ltu:diva-119807DOI: 10.1109/FiCloud70576.2026.00054Scopus ID: 2-s2.0-105049591450OAI: oai:DiVA.org:ltu-119807DiVA, id: diva2:2102847
Conference
13th International Conference on Future Internet of Things and Cloud (FiCloud 2026), Granada, Spain, July 20-22, 2026
Note

ISBN for host publication: 979-8-3195-4739-2

Available from: 2026-09-18 Created: 2026-09-18 Last updated: 2026-09-18Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Andersson, Karl

Search in DiVA

By author/editor
Andersson, Karl
By organisation
Computer Science
Signal ProcessingOther Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 22 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf