Open this publication in new window or tab >>2026 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]
Background:Total hip replacement is one of the most successful orthopaedic interventions; however, wearremains a key factor influencing long-term implant performance and survivorship. Additivelymanufactured (AM) PEEK materials have emerged as potential candidates for orthopaedicbearing applications, although their tribological and biological performance under clinically representative conditions remains insufficiently understood.
Aim: The aim of this thesis was to evaluate the tribological and biological performance of AMPEEK materials for orthopaedic bearing applications, focusing on the influence of manufacturing, surface finishing, composite reinforcement, and wear particle isolation and characterisation. In parallel, the thesis investigated the influence of physiologically representative loading profiles on wear behaviour in conventional metal-on-polymer systemsto assess limitations in current preclinical testing approaches.
Methods: This thesis combined a systematic review with experimental evaluation of AM PEEKmaterials and conventional orthopaedic bearing systems. Tribological performance wasassessed using multidirectional pin-on-disc testing under clinically relevant articulationconditions, including evaluation of surface topography, wear behaviour, and wear particlegeneration. A vacuum oven stabilisation approach was developed to improve gravimetric assessment of AM PEEK by reducing the influence of manufacturing-induced porosity onfluid absorption and mass stability.Wear particles were isolated using a phenol-based separation method designed to retain both polyethylene and PEEK particles despite similarities in material and protein density, before characterisation using scanning electron microscopy and in vitro biological assays. Inparallel, physiologically representative loading profiles were applied to conventional metalon-polymer hip systems using full-scale hip simulator testing to investigate their influence on preclinical wear assessment.
Key findings: Surface integrity was identified as a critical determinant of tribological performance in AMPEEK, with manufacturing-induced porosity and surface condition exerting greater influence than surface roughness alone. A vacuum oven stabilisation approach enabled improved gravimetric assessment of AM PEEK by reducing variability associated with fluid uptake and release. A phenol-based isolation method enabled recovery and characterisation of both polyethylene and PEEK wear particles for biological evaluation. AM PEEK demonstrated biological responses comparable to conventional materials, although composite reinforcement did not improve wear or biological performance. Finally, physiologically representative loading increased wear in conventional metal-on-polymer systems relative to standardised conditions, highlighting the importance of clinically representative preclinical evaluation, to prevent underestimation of wear in-situ.
Interpretation: Collectively, the findings indicate that tribological performance of additively manufactured PEEK is governed more strongly by manufacturing- and finish-induced surface integrity thanby surface roughness alone. Physiologically representative loading and multidirection alarticulation substantially influenced wear behaviour, highlighting limitations of simplified preclinical testing approaches and reinforcing the importance of clinically relevant evaluationframeworks. Furthermore, while additively manufactured PEEK demonstrated biological responses comparable to conventional materials, improvements in tribological performance remain important for supporting further biological validation and development of orthopaedic bearing systems.
Conclusions: This thesis demonstrates the importance of clinically relevant tribological evaluation forassessing emerging orthopaedic bearing materials. Physiologically representative loading altered wear behaviour in conventional metal-on-polymer systems, while multidirectional articulation provided greater insight into the tribological performance of additively manufactured PEEK materials.While additively manufactured PEEK demonstrated biological responses comparable toconventional materials, tribological performance remained strongly dependent on manufacturing- and finish-induced surface integrity and was not improved through theintroduction of composite reinforcement. Overall, the findings support continued investigation of additively manufactured PEEK as a candidate orthopaedic bearing material, while highlighting the need for further optimisationof manufacturing processes and more clinically representative evaluation methodologies prior to translation.
Place, publisher, year, edition, pages
Luleå: Luleå University of Technology, 2026
Series
Doctoral thesis / Luleå University of Technology, ISSN 1402-1544
Keywords
Total hip replacement, Orthopaedic tribology, Polyetheretherketone (PEEK), Additive manufacturing, Wear, Wear particles, Multidirectional articulation, Physiological loading, Surface integrity, Biological response
National Category
Bio Materials Composite Science and Engineering Other Mechanical Engineering Manufacturing, Surface and Joining Technology
Research subject
Machine Elements
Identifiers
urn:nbn:se:ltu:diva-120057 (URN)978-91-8142-167-5 (ISBN)978-91-8142-168-2 (ISBN)
Public defence
2026-12-01, E231, Luleå University of Technology, Luleå, 09:00 (English)
Opponent
Supervisors
2026-10-082026-10-062026-11-03Bibliographically approved