A Monte Carlo method is used to study the propagation of temperature uncertainties into relative humidity with respect to ice (RH i ) calculated from specific humidity. For a flat specific humidity distribution and Gaussian temperature uncertainties the resulting RH i distribution drops exponentially at high RH i values—much slower than a Gaussian. This agrees well with the RH i distribution measured by the Microwave Limb Sounder (MLS), which means that such remotely measured RH i distributions can be explained, at least partly, by temperature uncertainties.