Detection of laser induced dielectric breakdown in water using a laser doppler vibrometer
Department of Electrical and Information Engineering and Infotech Oulu, University of Oulu, P.O. Box 4500, 90014 University of Oulu, Finland.
Luleå University of Technology, Department of Computer Science, Electrical and Space Engineering, Embedded Internet Systems Lab.ORCID iD: 0000-0002-2833-2555
Luleå University of Technology, Department of Computer Science, Electrical and Space Engineering, Signals and Systems.ORCID iD: 0000-0003-3268-1691
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Fluid and Experimental Mechanics.ORCID iD: 0000-0001-8355-2414
Show others and affiliations
2010 (English)In: Central European Journal of Physics, ISSN 1895-1082, E-ISSN 1644-3608, Vol. 8, no 2, p. 235-241Article in journal (Refereed) Published
Abstract [en]

This study is focused on exploring the feasibility of an all-optic surface scanning method in determining the size and position of a submerged, laser generated, optoacoustic source. The optoacoustic effect was here generated when the absorption of a short electromagnetic pulse in matter caused a dielectric breakdown, a plasma emission flash and a subsequent acoustic wave. In the experiment, a laser pulse with l = 1064 nm and 12 ns pulse length was aimed at a volume of deionized water. When the laser beam was focused by a f = 16 mm lens, a single dielectric breakdown spot occurred. When a f = 40 mm was used several breakdowns in a row were induced. The breakdowns were photographed using a double shutter camera. The acoustic wave generated by the dielectric breakdowns were detected at a point on the water surface using a laser Doppler vibrometer (LDV). First, the LDV signal was used to calculate the speed of sound with an accuracy of 10 m/s. Secondly, the location and length of the dielectric breakdown was calculated with an accuracy of 1 mm. The calculated position matched the breakdown location recorded by a camera. The results show that it is possible to use LDV surface measurements from a single spot to determine both the position and length of the OA source as well as the speed of sound in the medium. Furthermore, the LDV measurements also show a secondary peak that originates from the OA source. To unravel the origin and properties of this interesting feature, further investigations are necessary.

Place, publisher, year, edition, pages
2010. Vol. 8, no 2, p. 235-241
Keywords [en]
dielectric breakdown, laser, vibrometer, optoacoustic, surface wave
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering Applied Mechanics Other Medical Engineering
Research subject
Industrial Electronics; Experimental Mechanics; Medical Engineering for Healthcare; Centre - Centre for Biomedical Engineering and Physics (CMTF)
Identifiers
URN: urn:nbn:se:ltu:diva-7456DOI: 10.2478/s11534-009-0122-9ISI: 000274108500012Scopus ID: 2-s2.0-75849122897Local ID: 5d630bd0-9d45-11de-a77c-000ea68e967bOAI: oai:DiVA.org:ltu-7456DiVA, id: diva2:980345
Note

Validerad; 2010; 20090909 (ysko);

Full text license: This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.

Available from: 2016-09-29 Created: 2016-09-29 Last updated: 2025-10-21Bibliographically approved

Open Access in DiVA

fulltext(674 kB)86 downloads
File information
File name FULLTEXT02.pdfFile size 674 kBChecksum SHA-512
93bca1df5c8903e42d9061e14171d9364f4bb54532761dce93198709a808ce57832ed3c05112f24b8173e44be843cd1d92be697885b1653eabcf93ac2362c8b3
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Authority records

Löfqvist, TorbjörnRamser, KerstinGren, PerOlsson, ErikNiemi, JanSjödahl, Mikael

Search in DiVA

By author/editor
Löfqvist, TorbjörnRamser, KerstinGren, PerOlsson, ErikNiemi, JanSjödahl, Mikael
By organisation
Embedded Internet Systems LabSignals and SystemsFluid and Experimental Mechanics
In the same journal
Central European Journal of Physics
Other Electrical Engineering, Electronic Engineering, Information EngineeringApplied MechanicsOther Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 395 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 505 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf