CT and PET Image Registration: Application to Thorax AreaShow others and affiliations
2013 (English)In: Journal of Image and Graphics, ISSN 2301-3699, Vol. 1, no 4, p. 171-175Article in journal (Refereed) Published
Abstract [en]
Accurate attenuation correction of emission data is mandatory for quantitative analysis of PET images. One of the main concerns in CT-based attenuation correction (CTAC) of PET data in multimodality PET/CT imaging is misalignment occurred due to respiratory artifact between PET and CT images. In this paper a combined method which is simple and fast is proposed for registration of PET and CT data to correct the effect of this artifact. The algorithm is composed of two step: First step is meant to reduce the noise by applying an adaptive gradient anistropic diffusion filter then using Iterative closest point (ICP) registration method in order to obtain initial estimation to ensure fast and accurate convergence of the algorithm. At the second step, the respiratory related artifact of PET images is greatly reduced by employing Free Form Deformation algorithm based on B-spline which provides more accurate adaptive transformation to align the images.
Place, publisher, year, edition, pages
2013. Vol. 1, no 4, p. 171-175
Keywords [en]
registration, PET, CT, thorax, FFD, CTAC, gradient anistropic diffusion filter
National Category
Applied Mechanics
Research subject
Experimental Mechanics
Identifiers
URN: urn:nbn:se:ltu:diva-7660DOI: 10.12720/joig.1.4.171-175Local ID: 61024779-a57d-4e99-a5f3-2a46e1832d5dOAI: oai:DiVA.org:ltu-7660DiVA, id: diva2:980550
Note
Godkänd; 2013; 20140217 (davkho)
2016-09-292016-09-292025-10-21Bibliographically approved