Boundary Conditions in Fire Protection Engineering
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Structural and Fire Engineering.ORCID iD: 0000-0003-2181-2828
2016 (English)In: Temperature Calculation in Fire Safety Engineering, Springer , 2016, p. 45-64Chapter in book (Refereed)
Abstract [en]

A summary of the three kinds of boundary conditions as outlined in Sect. 1.​1.​3 is shown in Table 4.1. The third kind of BC sometimes called natural BC is by far the most important and common boundary condition in fire protection engineering, while the first and second kinds of BCs can rarely be specified. The third kind of BC may be divided into three subgroups, (a), (b) and (c). The subgroup (b) and (c) are particularly suitable for fire engineering applications. Subgroup (a) is applied when the heat transfer coefficient may be assumed constant as assumed in Chaps. 2 and 3. T g is then the surrounding gas temperature. In fire protection engineering it is, however, generally not accurate enough to assume a constant heat transfer coefficient as in particular heat transfer by radiation is highly non-linear, i.e. the heat transfer coefficient varies with the surface temperature. Therefore the subgroups (3b) and (3c) are the most commonly applied. They consist of a radiation term and a convection term with the corresponding emissivity ε and convection heat transfer coefficient h, respectively. The subgroup (3b) presupposes a uniform temperature T f , i.e. the radiation temperature and the gas temperature are equal. This is assumed, for example, when applying time–temperature design curves according to standards such as ISO 834 or EN 1363-1 for evaluating the fire resistance of structures, see Chap. 12. The subgroup (3c) is a more general version of (3b) as it allows for different gas T g and radiation T r temperatures, so-called mixed boundary conditions. Alternatively σ⋅T 4 r σ⋅Tr4 may be replaced by an equivalent specified incident radiation q . ′′ inc q.inc′′ according to the identity q . ′′ inc ≡σ⋅T 4 r q.inc′′≡σ⋅Tr4 (Eq. 1.​17). As shown in Sect. 4.4 all boundary conditions of subgroup 3 may be written as type 3a. That means momentarily a single effective temperature named the adiabatic surface temperature (AST) with a value between the radiation and gas temperatures as well as a corresponding total heat transfer coefficient can always be defined, see Sect. 4.4.

Place, publisher, year, edition, pages
Springer , 2016. p. 45-64
National Category
Building Technologies
Research subject
Steel Structures
Identifiers
URN: urn:nbn:se:ltu:diva-20148DOI: 10.1007/978-3-319-30172-3_4Local ID: 261553f2-89f7-44ba-879d-c339a250a5eaISBN: 978-3-319-30170-9 (print)ISBN: 978-3-319-30172-3 (electronic)OAI: oai:DiVA.org:ltu-20148DiVA, id: diva2:993192
Note
Godkänd; 2016; 20160601 (andbra)Available from: 2016-09-29 Created: 2016-09-29 Last updated: 2025-10-21Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Wickström, Ulf

Search in DiVA

By author/editor
Wickström, Ulf
By organisation
Structural and Fire Engineering
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 302 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf